- ML20010A557 + (ML20010A557)
- ML20010A558 + (ML20010A558)
- ML20010A563 + (ML20010A563)
- ML20010A564 + (ML20010A564)
- ML20010A567 + (ML20010A567)
- ML20010A568 + (ML20010A568)
- ML20010A569 + (ML20010A569)
- ML20010A570 + (ML20010A570)
- IR 05000327/1981024 + (ML20010A572)
- ML20010A573 + (ML20010A573)
- ML20010A574 + (ML20010A574)
- AECM-81-290, Forwards Response to Unresolved Safety Issues A-1, waterhammer;A-9,ATWS;A-11,reactor Vessel Matls Toughness; A-17,sys Interaction in Nuclear Power plants;A-39,safety Relief Valve Pool Dynamic Loads & A-40,seismic Design + (ML20010A576)
- ML20010A577 + (ML20010A577)
- IR 05000389/1981010 + (ML20010A578)
- 05000237/LER-1981-044, Forwards LER 81-044/03L-0 + (ML20010A579)
- ML20010A580 + (ML20010A580)
- ML20010A581 + (ML20010A581)
- 05000272/LER-1981-069, Forwards LER 81-069/03L-0.Detailed Event Analysis Encl + (ML20010A583)
- ML20010A584 + (ML20010A584)
- 05000237/LER-1981-044-03, /03L-0:on 810703,average Power Range Monitor 6 Failed to Initiate Rod Block During Normal Operation.Caused by Failure of K-2 Relay Which Prevented Proper Operation of Relay K5.Monitor Bypassed & Relay Replaced + (ML20010A585)
- ML20010A586 + (ML20010A586)
- ML20010A587 + (ML20010A587)
- ML20010A588 + (ML20010A588)
- ML20010A589 + (ML20010A589)
- 05000272/LER-1981-069-03, /03L-0:on 810703,while Adjusting Svc Water Flow Through Component Cooling Water Heat Exchanger,Operator Found Flow Control Valve 12SW127 Would Not Open.Caused by Marred Sealing Surface of Valve Tube Bundle.Bundle Cut Back + (ML20010A591)
- ML20010A592 + (ML20010A592)
- ML20010A593 + (ML20010A593)
- ML20010A594 + (ML20010A594)
- 05000331/LER-1981-030, Forwards LER 81-030/03L-0 + (ML20010A595)
- ML20010A596 + (ML20010A596)
- ML20010A597 + (ML20010A597)
- ML20010A599 + (ML20010A599)
- 05000318/LER-1981-032, Forwards LER 81-032/03L-0 + (ML20010A600)
- ML20010A601 + (ML20010A601)
- 05000331/LER-1981-030-03, /03L-0:on 810701,torus Atmosphere Sampling Line Isolation Valve SV-8108A Would Not Close During Testing. Caused by Rust in Mechanical Portion of Solenoid,Impeding Proper Operation.Solenoid Dismantled & Cleaned + (ML20010A602)
- IR 05000139/1981005 + (ML20010A603)
- 05000369/LER-1981-107, Forwards LER 81-107/03L-0.Detailed Event Analysis Encl + (ML20010A604)
- ML20010A605 + (ML20010A605)
- ML20010A608 + (ML20010A608)
- 05000318/LER-1981-032-03, /03L-0:on 810704,during Operator Insp,Operator Noted Water Dripping from Reactor Coolant Pump 22 Bay.Cause Unknown.Repair Will Be Initiated When Sys Becomes Available for Maint + (ML20010A610)
- ML20010A611 + (ML20010A611)
- ML20010A612 + (ML20010A612)
- 05000369/LER-1981-107-03, /03L-0:on 810704,auxiliary Feedwater Flow Gauges for Steam Generator C & D Declared Inoperable.On 810706, Plant Entered Mode 3 from Mode 4.Caused by External Source Tied Into Instrument Loops Causing Power Supply to Fail + (ML20010A613)
- ML20010A614 + (ML20010A614)
- ML20010A615 + (ML20010A615)
- JAFP-81-0633, Advises That Revision of Instrument Maint Procedures Associated W/Ie Insp Rept 50-333/80-05 Cannot Be Completed by 810630.Revised Commitment Date Is 810815 + (ML20010A616)
- 05000220/LER-1981-032, Forwards LER 81-032/03L-0 + (ML20010A619)
- ML20010A620 + (ML20010A620)
- 05000335/LER-1981-037, Forwards LER 81-037/03L-0 + (ML20010A621)
- ML20010A623 + (ML20010A623)
- LD-81-040, Forwards Summary of 810622-25 SER Meeting in Windsor,Ct W/Mechanical Engineering Branch & Aps/Bechtel Re CESSAR-F, Chapter 3 + (ML20010A624)