Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20009G353 + (ML20009G353)
- ML20009G354 + (ML20009G354)
- ML20009G355 + (ML20009G355)
- ML20009G357 + (ML20009G357)
- ML20009G359 + (ML20009G359)
- ML20009G360 + (ML20009G360)
- ML20009G361 + (ML20009G361)
- 05000321/LER-1981-064, Forwards LER 81-064/03L-0 + (ML20009G362)
- ML20009G363 + (ML20009G363)
- ML20009G364 + (ML20009G364)
- ML20009G365 + (ML20009G365)
- ML20009G366 + (ML20009G366)
- 05000321/LER-1981-064-03, /03L-0:on 810701,HPCI Steam Line Pressure Switches 1E41-N001B & D Actuated at 101 & 106 Psig,Respectively. Caused by Switch Setpoint Drift.Switches Recalibr + (ML20009G367)
- ML20009G368 + (ML20009G368)
- ML20009G369 + (ML20009G369)
- ML20009G370 + (ML20009G370)
- 05000327/LER-1981-077, Forwards LER 81-077/03L-0 + (ML20009G372)
- ML20009G373 + (ML20009G373)
- ML20009G374 + (ML20009G374)
- ML20009G375 + (ML20009G375)
- 05000327/LER-1981-077-03, /03L-0:on 810628,refueling Water Storage Tank Was Found to Have Approx 45,000 Gallons Less than Required 370,000 Gallon Vol.Caused by Valve 1-62-500 Being Left Open from Earlier Boron Concentration Equalization Process + (ML20009G376)
- 05000339/LER-1981-053, Forwards LER 81-053/03L-0 + (ML20009G377)
- ML20009G378 + (ML20009G378)
- ML20009G382 + (ML20009G382)
- 05000339/LER-1981-053-03, /03L-0:on 810701,one of Two Parallel Steam Supply Valves Failed to Close Completely &,On 810703,other Valve Failed to Completely Close.Caused by Contaminants & Corrosion Products Causing Piston to Stick + (ML20009G383)
- ML20009G384 + (ML20009G384)
- 05000321/LER-1981-076, Forwards LER 81-076/03L-0 + (ML20009G386)
- ML20009G387 + (ML20009G387)
- ML20009G388 + (ML20009G388)
- ML20009G389 + (ML20009G389)
- ML20009G390 + (ML20009G390)
- IR 05000225/1981002 + (ML20009G391)
- 05000321/LER-1981-076-03, /03L-0:on 810708,during Testing,Both Dioxide Analyzers Were Found Reading Lower than Actual Concentration of Oxygen.Caused by Failure of Rochester Current Transmitter in Analyzer a & Calibr Drift in Analyzer B + (ML20009G392)
- ML20009G393 + (ML20009G393)
- 05000324/LER-1981-067, Forwards LER 81-067/03L-0 + (ML20009G394)
- ML20009G395 + (ML20009G395)
- LD-81-039, Forwards Amend 4 to Fsar,Adding New Large Break LOCA Analysis,Incorporating Extended Fuel Cycle Parameters & Mod of post-LOCA long-term Cooling Section to Discuss Emergency Procedure Guidelines + (ML20009G396)
- 05000324/LER-1981-067-03, /03L-0:on 810714,control Operator Discovered That Drywell Equipment Drain Flow Integrator Was Continually Counting W/No Pumps Running.Caused by Instrument Drift. Integrator Recalibr & Signal Response Checked + (ML20009G400)
- ML20009G401 + (ML20009G401)
- ML20009G402 + (ML20009G402)
- ML20009G405 + (ML20009G405)
- ML20009G406 + (ML20009G406)
- ML20009G408 + (ML20009G408)
- ML20009G410 + (ML20009G410)
- L-81-322, Informs That,Pending Completion & Testing of Prompt Notification Sys,County State Agencies Are Continuing W/Established Plans to Alert & Notify Persons in Offsite Areas by Dispatching Law Enforcement Vehicles W/Sirens + (ML20009G411)
- ML20009G412 + (ML20009G412)
- ML20009G413 + (ML20009G413)
- 05000335/LER-1981-033, Forwards LER 81-033/03L-0 + (ML20009G414)
- ML20009G415 + (ML20009G415)
- ML20009G416 + (ML20009G416)
- ML20009G417 + (ML20009G417)