ML20009G388

From kanterella
Jump to navigation Jump to search

Forwards Final Rept on Design Review of Plant Shielding & Environ Qualification of Equipment for Spaces/Sys Outside Containment Which May Be Used in Post-Accident Operations, in Response to NUREG-0737,Item II.B.2
ML20009G388
Person / Time
Site: Hatch  
Issue date: 07/27/1981
From: Beckman J
GEORGIA POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20009G389 List:
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.B.2, TASK-TM TAC-47943, TAC-47944, NUDOCS 8108040199
Download: ML20009G388 (1)


Text

,

Gnarga Pcner comp;iny 333 Pedmont Avenue A tla nt,1 G x;rg a 30308 Te!ephone 404 526-/020 f/aAng Ad1 ess

~

Post Offce Box 4545 A:Qnta Georg.a 30302 Georgia Power J. T. Beckham, Jr.

Wr e Pres 6 n! and General Manager Nudear Gervrat:en July 27,1981 co g

s 6!E.l13 s

9

..n

~

AUG O 31981> r Director of !!uclear Reactor Regulation

'9; 7

ll.S. Iluclear Regulatory Connission mmet p

11ashington, D. C. 20555 y

n

/

Col l,

HRC DOCKETS 50-321, 50-366 OPERATIllG LICEllSES DPR-57, HPF-5 EDilIll I. HATCll flUCLEAR PLAtlT UllITS 1, 2 IlUREG 0737 ITEM II.B.2 - POST ACCIDENT SHIELDING t

Gentlenen:

Your June 10, 1981 letter requested that the final post-accident plant shielding analysis and design be subnitted for review. Enclosed is that report.

It should be noted that this report is a revision of the previous submittal and engineering design which had been completed in 1980. That design was determined to be inpractical for inplenentation and the present re-analysis and design were developed for use.

If you require further infornation, please contact my office.

Yours very truly,

}

Y-J. T. Beckhan, Jr.

Vice President and General fianager fluclear Generation f

Enclosure llEB/eb Q

xc: !!ax flanry g

R. F. Rogers, III 5'

ho uc 00 P