- ML20009E470 + (ML20009E470)
- 05000366/LER-1981-066, Forwards LER 81-066/03L-0 + (ML20009E471)
- ML20009E472 + (ML20009E472)
- ML20009E473 + (ML20009E473)
- ML20009E475 + (ML20009E475)
- 05000366/LER-1981-066-03, /03L-0:on 810626,while Operating at 92% Power,B Diesel Tripped During Surveillance Test HNP-2-01,diesel Generator Manual Start.Standby Svc Water Sys Would Not Deliver Rated Flow.Caused by Debris Blocking Flow to Pump + (ML20009E477)
- ML20009E480 + (ML20009E480)
- PNO-V-81-043, on 810724,licensee Committed to Provide Preliminary Rept on Significant Voids in Auxiliary Bldg Concrete Placement,Discovered in NRC 810713-17 Insp & 810723 & 24 Telcons,Nrc Site Insp Will Begin on 810727 + (ML20009E481)
- ML20009E484 + (ML20009E484)
- ML20009E488 + (ML20009E488)
- ML20009E489 + (ML20009E489)
- 05000366/LER-1981-068, Forwards LER 81-068/03L-0 + (ML20009E491)
- ML20009E492 + (ML20009E492)
- ML20009E498 + (ML20009E498)
- 05000366/LER-1981-068-03, /03L-0:on 810701,while Performing Remote Shutdown Panel Channel Check Functional Test,Remote Shutdown Panel RPV Pressure Indicator Found Out of Tolerance.Caused by Calibr Drift.Instrument Recalibr + (ML20009E499)
- ML20009E501 + (ML20009E501)
- AECM-81-248, Provides Results of Preliminary Review of Generic BWR Safety/Relief Valve Test Program,In Response to NUREG-0737, Item II.D.1.Tested Valve Satisfies Acceptance Criteria for Operability + (ML20009E502)
- 05000267/LER-1981-039, Forwards LER 81-039/03L-0.Detailed Event Analysis Encl + (ML20009E504)
- ML20009E505 + (ML20009E505)
- ML20009E508 + (ML20009E508)
- ML20009E509 + (ML20009E509)
- 05000267/LER-1981-039-03, /03L-0:on 810602,following Routine Chlorination of Circulating Water Sys,Sample Indicated Excessive Residual Chlorine in Plant Liquid Effluent.Cause Unknown.Subsequent Chlorinations Showed No Abnormalities + (ML20009E510)
- IR 05000206/1981020 + (ML20009E511)
- 05000260/LER-1981-030, Forwards LER 81-030/03L-0 + (ML20009E514)
- ML20009E515 + (ML20009E515)
- ML20009E517 + (ML20009E517)
- ML20009E518 + (ML20009E518)
- ML20009E519 + (ML20009E519)
- ML20009E520 + (ML20009E520)
- ML20009E522 + (ML20009E522)
- ML20009E523 + (ML20009E523)
- ML20009E525 + (ML20009E525)
- 05000260/LER-1981-030-03, /03L-0:on 810629,while Performing Surveillance Insp 4.5.B.1.D,valve 2-FCV-2-74-57 Became Inoperable,Making RHR Loop I Inoperable.Caused by Geared Limit Finger Base Breaking Off of Operator.Finger Base Replaced + (ML20009E526)
- RA-19-0471, Request for an Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System + (ML20009E527)
- 05000369/LER-1981-100-03, /03L-0:on 810616,in Mode 5,curve on Lower Wind Direction Monitoring Instrument Recorder Strip Chart Discovered Unrealistic.Caused by Failure of Wind Sensor Shaft Bearing.Sensor Replaced + (ML20009E530)
- ML20009E531 + (ML20009E531)
- ML20009E532 + (ML20009E532)
- 05000296/LER-1981-031, Forwards LER 81-031/03L-0 + (ML20009E533)
- ML20009E534 + (ML20009E534)
- 05000302/LER-1981-032, Forwards LER 81-032/03L-0 + (ML20009E536)
- ML20009E537 + (ML20009E537)
- 05000261/LER-1981-017, Forwards LER 81-017/03L-0 + (ML20009E538)
- ML20009E539 + (ML20009E539)
- 05000296/LER-1981-031-03, /03L-0:on 810624,during Normal Operations 3-A Reactor Recirculation Pump Tripped Due to 2A-K45A Relay Action.Caused by Resistance Temp Detector High Temp Trip. Unit Load Reduced.Ge Motor Generator Set & Restarted + (ML20009E542)
- ML20009E547 + (ML20009E547)
- 05000267/LER-1981-040, Forwards LER 81-040/03L-0.Detailed Event Analysis Encl + (ML20009E549)
- ML20009E550 + (ML20009E550)
- 05000302/LER-1981-032-03, /03L-0:on 810616,during Normal Operation,Decay Heat Closed Cycle Cooling Pump Supply Fan AHF-15B Discovered Noisy.Fan Declared Inoperable.Caused by Worn Bearings.Sealed Bearings Replaced + (ML20009E551)
- 05000366/LER-1981-060, Forwards LER 81-060/03L-0 + (ML20009E554)
- ML20009E555 + (ML20009E555)