Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20009C077 + (ML20009C077)
- 05000369/LER-1981-087-03, /03L-0:on 810518,during Initial Fuel Loading,Flow Indicator of Gross Radioactivity Monitor (EMF-31) on Waste Water Treatment Line Was Found Not Functioning.Caused by Clogged Flow Switch & Strainer.Monitor Cleaned + (ML20009C078)
- 05000369/LER-1981-040, Forwards LER 81-040/03L-0.Detailed Event Analysis Encl + (ML20009C079)
- ML20009C080 + (ML20009C080)
- 05000369/LER-1981-040-03, /03L-0:on 810405,while in Mode 4,initial Fuel Loading,Pressure Gauges a & D Indicated Pressure W/No Actual Pressure in Steam Lines.Caused by Faulty Transmitters. Transmitters Replaced,Tested & Calibr + (ML20009C081)
- ML20009C082 + (ML20009C082)
- ML20009C084 + (ML20009C084)
- ML20009C085 + (ML20009C085)
- ML20009C086 + (ML20009C086)
- ML20009C087 + (ML20009C087)
- ML20009C088 + (ML20009C088)
- ML20009C090 + (ML20009C090)
- ML20009C092 + (ML20009C092)
- IR 05000295/1981012 + (ML20009C093)
- 05000287/LER-1980-016, Forwards LER 80-016/03L-1.Detailed Event Analysis Encl + (ML20009C095)
- ML20009C097 + (ML20009C097)
- 05000287/LER-1980-016-03, /03L-1:on 801123,fire Detectors String B-2 Went Into Alarm Condition.Caused by Dust Buildup in Detector. Detector Cleaned & Verified Operable + (ML20009C098)
- 05000287/LER-1981-009, Forwards LER 81-009/03L-0.Detailed Event Analysis Encl + (ML20009C099)
- ML20009C101 + (ML20009C101)
- ML20009C102 + (ML20009C102)
- 05000369/LER-1981-060, Forwards LER 81-060/03L-0.Detailed Event Analysis Encl + (ML20009C103)
- ML20009C104 + (ML20009C104)
- 05000369/LER-1981-047, Forwards LER 81-047/03L-0.Detailed Event Analysis Encl + (ML20009C105)
- ML20009C106 + (ML20009C106)
- 05000287/LER-1981-009-03, /03L-0:on 810507,containment Isolation Valve 3CS-6 Was Discovered in Intermediate Position,Resulting in Loss of Containment Integrity.Cause Undetermined.Valve 3CS-6 Verified Operable + (ML20009C107)
- 05000369/LER-1981-060-03, /03L-0:on 810420,while in Mode 3,initial Fuel Loading,Channel 1 Cold Leg Injection Accumulator 1D Tank Level Indicator Fluctuated & Failed High.Caused by Faulty Transmitter.New Transmitter Installed & Calibr + (ML20009C108)
- 05000287/LER-1981-011, Forwards LER 81-011/03L-0.Detailed Event Analysis Encl + (ML20009C109)
- ML20009C111 + (ML20009C111)
- 05000369/LER-1981-047-03, /81-03L-0:on 810408,while in Mode 4,containment Particulate Radiation Activity Monitor EMF-38 Was Declared Inoperable Due to False High Radiation Alarm.Caused by Low Level Setting of Alarm Setpoints.Setpoints Adjusted + (ML20009C112)
- 05000369/LER-1981-089, Forwards LER 81-089/03L-0.Detailed Event Analysis Encl + (ML20009C113)
- ML20009C114 + (ML20009C114)
- 05000287/LER-1981-011-03, /03L-0:on 810518,safety-related Mechanical Snubber Was Discovered Inoperable During Visual Insp.Caused by Ball Screw Shaft of Snubber Being Slightly Scored,Prohibiting Ball Bearings from Running Smoothly.Snubber Replaced + (ML20009C115)
- 05000270/LER-1981-001, Forwards LER 81-001/03X-1.Detailed Event Analysis Encl + (ML20009C116)
- ML20009C117 + (ML20009C117)
- 05000369/LER-1981-089-03, /03L-0:on 810522,while in Mode 5,noble Gas Activity Monitor EMF-33,on Condenser Steam Air Ejector Sys Would Not Function in Auto Mode.Caused by Water Being Aspirated from Loop Into Vacuum Pump.Pump Restarted + (ML20009C118)
- 05000369/LER-1981-048, Forwards LER 81-048/03L-0.Detailed Event Analysis Encl + (ML20009C119)
- ML20009C120 + (ML20009C120)
- 05000270/LER-1981-001-03, /03X-1:on 810120,discovered That Low Pressure Svc Water Was Not Flowing to HPI Pump 2A.Caused by Blockage Due to Crud Buildup.Portions of Carbon Steel Piping Will Be Replaced W/Stainless Steel + (ML20009C122)
- 05000346/LER-1981-035, Forwards LER 81-035/03T-0 + (ML20009C123)
- ML20009C124 + (ML20009C124)
- ML20009C126 + (ML20009C126)
- ML20009C128 + (ML20009C128)
- 05000369/LER-1981-048-03, /03L-0:on 810410,while in Mode 3,wide Range Level Instrument for Steam Generator B Remote Shutdown Monitoring Instrumentation Was Pegged High & Declared Inoperable.Caused by Valved Out Transmitter + (ML20009C129)
- ML20009C130 + (ML20009C130)
- ML20009C132 + (ML20009C132)
- ML20009C134 + (ML20009C134)
- ML20009C135 + (ML20009C135)
- ML20009C137 + (ML20009C137)
- ML20009C139 + (ML20009C139)
- ML20009C140 + (ML20009C140)
- ML20009C141 + (ML20009C141)