Date released: 01/23/2020 Download: ML20009C080


LER 81-040/03L-0:on 810405,while in Mode 4,initial Fuel Loading,Pressure Gauges a & D Indicated Pressure W/No Actual Pressure in Steam Lines.Caused by Faulty Transmitters. Transmitters Replaced,Tested & Calibr