- AECM-81-159, Final Deficiency Rept Re Reactor Pressure Vessel Level Sensing Lines,Initially Reported 800808.AE Has Completed Pipe Sleeve Extension to Recirculation Discharge Line Penetrations in Shield Wall.Corrections Completed 810601 + (ML20008F917)
- ML20008F918 + (ML20008F918)
- ML20008F919 + (ML20008F919)
- 05000245/LER-1981-006, Forwards LER 81-006/03L-0.Detailed Event Analysis Encl + (ML20008F920)
- ML20008F922 + (ML20008F922)
- 05000245/LER-1981-006-03, /03L-0:on 810417,one of Two Ventilation Duct Radiation Monitors Was Found to Trip Outside Allowable Range.Caused by Setpoint Drift Due to Failed Sensor Converter.Converter Replaced + (ML20008F923)
- ML20008F924 + (ML20008F924)
- ML20008F925 + (ML20008F925)
- ML20008F926 + (ML20008F926)
- ML20008F928 + (ML20008F928)
- ML20008F929 + (ML20008F929)
- ML20008F930 + (ML20008F930)
- ML20008F935 + (ML20008F935)
- 05000315/LER-1981-010, Forwards LER 81-010/03L-0 + (ML20008F941)
- 05000338/LER-1981-023, Forwards LER 81-023/03L-0 + (ML20008F942)
- ML20008F943 + (ML20008F943)
- 05000338/LER-1981-023-03, /03L-0:on 810411,individual Rod Position Indication for Rod B-08 in Control Bank D Deviated from Group Demand Position.Caused by Instrument Drift.Indicator Channel Recalibr + (ML20008F944)
- 05000339/LER-1981-033, Forwards LER 81-033/03L-0 + (ML20008F945)
- ML20008F946 + (ML20008F946)
- 05000366/LER-1981-035-03, /03L-0:on 810413,during Steady State Operation, Reactor Bldg to Torus Vacuum Breaker Isolation valve,2T48- F310,failed to Open Due to Failure of Differential Pressure switch,2T48-N210.Mechanism Cleaned.New Switch Ordered + (ML20008F947)
- ML20008F948 + (ML20008F948)
- 05000339/LER-1981-033-03, /03L-0:on 810414,during Mode 1 Operation at 100% Power,B Train Quench Spray Subsys Removed from Svc to Repair Leaking Drain Valve on Pump Discharge Line.Valve Repaired & Disc Replaced.Pump Returned to Svc + (ML20008F950)
- 05000321/LER-1981-030, Forwards LER 81-030/03L-0 + (ML20008F951)
- ML20008F952 + (ML20008F952)
- ML20008F953 + (ML20008F953)
- 05000321/LER-1981-030-03, /03L-0:on 810413,during Refueling outage,1C71- K751B & D,Rps M-G Set Overvoltage Relays & 1C71-K752C,RPS M-G Set Undervoltage Relay Did Not Actuate.Caused by Setpoint Drift.Relays Recalibr & Returned to Svc + (ML20008F954)
- 05000366/LER-1981-028, Forwards LER 81-028/03L-0 + (ML20008F955)
- ML20008F956 + (ML20008F956)
- ML20008F957 + (ML20008F957)
- 05000366/LER-1981-040, Forwards LER 81-040/03L-0 + (ML20008F958)
- ML20008F959 + (ML20008F959)
- ML20008F960 + (ML20008F960)
- ML20008F961 + (ML20008F961)
- 05000366/LER-1981-028-03, /03L-0:on 810407,during Steady State Operation, Electrolyte Level in Some Cells of 2R42-S001A & B Station Batteries & 2R42-S002A Diesel Generator Battery Found Above High Level Mark.Caused by Personnel & Procedure Errors + (ML20008F962)
- 05000366/LER-1981-040-03, /03L-0:on 810423,hydraulic Control Unit Accumulator Low Pressure Alarm Annunciated for Rod 46-23. Caused by Accumulator Pressure Having Bled Down Below Tech Spec Level.Accumulator Recharged & Restored + (ML20008F963)
- 05000366/LER-1981-029, Forwards LER 81-029/03L-0 + (ML20008F964)
- ML20008F965 + (ML20008F965)
- ML20008F966 + (ML20008F966)
- 05000254/LER-1981-009, Forwards LER 81-009/03L-0 + (ML20008F967)
- ML20008F968 + (ML20008F968)
- 05000366/LER-1981-032, Forwards LER 81-032/03L-0 + (ML20008F969)
- ML20008F970 + (ML20008F970)
- 05000366/LER-1981-029-03, /03L-0:on 810408,during 100% Power,Rcic Inboard Steam Supply Isolation Valve Could Not Be Reopened After Closing on Isolation Signal.Caused by Excessive Activation & Tripped Breaker.Breaker Reset & Valve Tested + (ML20008F971)
- 05000254/LER-1981-009-03, /03L-0:on 810407,while 1A RHR Svc Water Pump Being Run for Packing Adjustment,Pump Failed to Meet Flow Requirements of 3,500 Gpm at 198 Psig.Caused by 3 Pieces of Wood in Pump Suction.Packing Sleeve & Bearings Replaced + (ML20008F972)
- ML20008F973 + (ML20008F973)
- 05000366/LER-1981-032-03, /03L-0:on 810410,HPCI Auxiliary Oil Pump Tripped During Second HPCI Sys Manual Initiation.Caused by Coil Failure in Time Delay Relay Not Allowing Relay Contact.Coil Replaced,Pump Rerun & Design Change Initiated + (ML20008F974)
- ML20008F975 + (ML20008F975)