- 05000318/LER-1981-003-03, /03L-0:on 810123,shutdown Cooling Return Header Isolation valve,MOV-652,lost Valve Position Indication & Flow Was Stopped.Caused by Motor Control Center Power Transfer.Transfer Completed,Indication & Flow Restored + (ML20003B619)
- 05000333/LER-1981-013, Forwards LER 81-013/03L-0 + (ML20003B620)
- ML20003B621 + (ML20003B621)
- ML20003B622 + (ML20003B622)
- ML20003B623 + (ML20003B623)
- 05000333/LER-1981-013-03, /03L-0:on 810124,HPCI Sys Flow Square Root Computation Module Found Out of Calibr.Possibly Caused by Instrument Drift.Instrument Recalibr & Returned to Svc + (ML20003B624)
- ML20003B625 + (ML20003B625)
- ML20003B626 + (ML20003B626)
- 05000321/LER-1981-003, Forwards LER 81-003/03L-0 + (ML20003B627)
- ML20003B628 + (ML20003B628)
- ML20003B629 + (ML20003B629)
- 05000321/LER-1981-003-03, /03L-0:on 810130,HPCI Governor Valve Stuck Open. Caused by Lift Rod Being Bent & Galled Due to Interference Between Lift Rod Fork Connector & Valve Lever.Damaged Rod Replaced,Upper Guide Bushing Honed & Fork Modified + (ML20003B630)
- ML20003B631 + (ML20003B631)
- 05000366/LER-1981-007, Forwards LER 81-007/03L-0 + (ML20003B632)
- ML20003B633 + (ML20003B633)
- ML20003B634 + (ML20003B634)
- ML20003B635 + (ML20003B635)
- ML20003B636 + (ML20003B636)
- 05000366/LER-1981-007-03, /03L-0:on 810126,discovered That on 810124 & 25 Reactor Coolant Sampled from Wrong Sample Line.Caused by Lack of Communication Among Personnel Who Collect & Analyze Reactor Coolant.Personnel Instructed & Coolant Sampled + (ML20003B637)
- ML20003B638 + (ML20003B638)
- ML20003B639 + (ML20003B639)
- ML20003B642 + (ML20003B642)
- ML20003B643 + (ML20003B643)
- ML20003B645 + (ML20003B645)
- ML20003B646 + (ML20003B646)
- ML20003B647 + (ML20003B647)
- ML20003B649 + (ML20003B649)
- ML20003B650 + (ML20003B650)
- ML20003B651 + (ML20003B651)
- ML20003B652 + (ML20003B652)
- 05000309/LER-1980-014, Forwards LER 80-014/01X-1 + (ML20003B653)
- ML20003B655 + (ML20003B655)
- ML20003B656 + (ML20003B656)
- 05000309/LER-1980-014-01, /01X-1:on 800604,analysis of Reactor Vessel Wall Surveillance Capsule Indicated Higher Shift of RTNDT than Predicted.Caused by Calculation Programs &/Or Errors in Methodology.Preparation of Tech Specs Amend Underway + (ML20003B657)
- ML20003B658 + (ML20003B658)
- ML20003B659 + (ML20003B659)
- ML20003B660 + (ML20003B660)
- ML20003B661 + (ML20003B661)
- ML20003B662 + (ML20003B662)
- ML20003B663 + (ML20003B663)
- ML20003B665 + (ML20003B665)
- ML20003B666 + (ML20003B666)
- ML20003B667 + (ML20003B667)
- ML20003B668 + (ML20003B668)
- ML20003B669 + (ML20003B669)
- ML20003B670 + (ML20003B670)
- ML20003B671 + (ML20003B671)
- ML20003B672 + (ML20003B672)
- ML20003B673 + (ML20003B673)
- ML20003B674 + (ML20003B674)
- ML20003B676 + (ML20003B676)