Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000368/LER-1980-081-03, /03L-0:on 801030,fire Watch Not Maintained Continuously While Pipe to 2VUC-21 Through Fire Barrier Replaced.Caused by Inadequate Written Specs.New Control of Maint Procedures Addresses Problem + (ML19345B755)
- ML19345B756 + (ML19345B756)
- ML19345B758 + (ML19345B758)
- ML19345B759 + (ML19345B759)
- ML19345B760 + (ML19345B760)
- ML19345B761 + (ML19345B761)
- ML19345B763 + (ML19345B763)
- ML19345B764 + (ML19345B764)
- 05000029/LER-1980-019, Forwards LER 80-019/03L-0 + (ML19345B765)
- ML19345B767 + (ML19345B767)
- ML19345B768 + (ML19345B768)
- ML19345B769 + (ML19345B769)
- 05000029/LER-1980-019-03, /03L-0:on 801030,during Turbine Startup in Mode 2, Left Hand Throttle Valve Failed to Close Tightly Causing Turbine to Accelerate.Caused by Pilot Valve Failure.Left Hand Throttle Disassembled & Pilot Valve Replaced + (ML19345B770)
- ML19345B771 + (ML19345B771)
- ML19345B772 + (ML19345B772)
- ML19345B773 + (ML19345B773)
- ML19345B774 + (ML19345B774)
- AECM-80-236, Forwards Interim Security Plan for Fuel Storage.Plan Withheld (Ref 10CFR2.790) + (ML19345B775)
- 05000331/LER-1980-055, Forwards LER 80-055/01T-0 + (ML19345B776)
- 05000324/LER-1980-093, Forwards LER 80-093/03L-0 + (ML19345B777)
- ML19345B779 + (ML19345B779)
- ML19345B780 + (ML19345B780)
- 05000366/LER-1980-145, Forwards LER 80-145/03L-0 + (ML19345B781)
- ML19345B782 + (ML19345B782)
- ML19345B783 + (ML19345B783)
- ML19345B784 + (ML19345B784)
- 05000317/LER-1980-056, Forwards LER 80-056/03L-0 + (ML19345B785)
- ML19345B786 + (ML19345B786)
- 05000366/LER-1980-145-03, /03L-0:on 801029,standby Svc Water Pump Flow & Dynamic Head Data Found Out of Compliance W/Asme Code Section 11,Table IWP-3100-2.Cause Not Stated.Corrective Maint Performed & Pump Retested + (ML19345B787)
- ML19345B788 + (ML19345B788)
- ML19345B790 + (ML19345B790)
- 05000364/LER-1980-001, Forwards LER 80-001/01T-0 + (ML19345B791)
- ML19345B792 + (ML19345B792)
- ML19345B793 + (ML19345B793)
- ML19345B794 + (ML19345B794)
- ML19345B796 + (ML19345B796)
- 05000364/LER-1980-001-01, /01T-0:on 801112,water for Lubrication & Cooling of a Train Svc Water Pumps Found to Be Provided by B Train Svc Water Header & Vice Versa.Caused by Design Error.Design Change to Provide Correct Separation Completed + (ML19345B797)
- ML19345B799 + (ML19345B799)
- ML19345B800 + (ML19345B800)
- 05000336/LER-1980-037, Forwards LER 80-037/03L-0 + (ML19345B801)
- ML19345B802 + (ML19345B802)
- 05000317/LER-1980-056-03, /03L-0:on 801028,performance of STP M-13-1, Inaccessible Snubber Visual Insp,Revealed Five Snubbers, 1-54-6,-6A,-7,-7A & 1-60-27 Inoperable.Caused by Loss of Hydraulic Oil.Mods Completed + (ML19345B803)
- ML19345B805 + (ML19345B805)
- ML19345B806 + (ML19345B806)
- ML19345B807 + (ML19345B807)
- 05000219/LER-1980-047, Forwards LER 80-047/03L-0 + (ML19345B808)
- ML19345B809 + (ML19345B809)
- 05000219/LER-1980-047-03, /03L-0:on 801101,while Performing Core Spray Sys Instrument Channel Calibr & Test,High Drywell Pressure Switches Tripped Above Tech Spec Limit.Cause Attributed to Instrument Repeatability.Switches Adjusted + (ML19345B810)
- 05000348/LER-1980-069-01, /01T-0:on 801112,water for Lubrication & Cooling of a Train Svc Water Pumps Found to Be Provided by B Train Water Header & Vice Versa.Caused by Design Error.Design Change to Provide Correct Separation Completed + (ML19345B811)
- ML19345B812 + (ML19345B812)
- ML19345B813 + (ML19345B813)