- 05000348/LER-1980-046, Forwards LER 80-046/03L-0 + (ML19343A169)
- ML19343A170 + (ML19343A170)
- ML19343A171 + (ML19343A171)
- ML19343A172 + (ML19343A172)
- ML19343A173 + (ML19343A173)
- 05000348/LER-1980-046-03, /03L-0:on 800813,steam Flow Channel Associated W/ Flow Transmitter 475 Failed Low. Caused by Defective Loop Power Supply Cord. Cord Replaced & Channel Returned to Svc + (ML19343A174)
- ML19343A175 + (ML19343A175)
- ML19343A176 + (ML19343A176)
- ML19343A177 + (ML19343A177)
- ML19343A178 + (ML19343A178)
- ML19343A179 + (ML19343A179)
- ML19343A181 + (ML19343A181)
- ML19343A182 + (ML19343A182)
- ML19343A183 + (ML19343A183)
- ML19343A184 + (ML19343A184)
- ML19343A185 + (ML19343A185)
- ML19343A187 + (ML19343A187)
- TXX-3190, Responds to 800814 Request for Addl Info.Answers to Questions from Instrumentation & Controls Sys Branch & Anl Consultants Will Be Submitted by Amend to FSAR on 801031 + (ML19343A188)
- ML19343A189 + (ML19343A189)
- ML19343A190 + (ML19343A190)
- ML19343A191 + (ML19343A191)
- ML19343A192 + (ML19343A192)
- ML19343A193 + (ML19343A193)
- ML19343A194 + (ML19343A194)
- ML19343A196 + (ML19343A196)
- ML19343A197 + (ML19343A197)
- 05000293/LER-1980-053, Forwards LER 80-053/03L-0 + (ML19343A198)
- ML19343A199 + (ML19343A199)
- 05000293/LER-1980-053-03, /03L-0:on 800814,HPCI Snubber 23-3-36 Was Found to Be Inoperable.Caused by Low Reservoir Fluid.Analysis by Engineering Dept Underway + (ML19343A200)
- 05000293/LER-1980-052, Forwards LER 80-052/03L-0 + (ML19343A201)
- ML19343A202 + (ML19343A202)
- ML19343A203 + (ML19343A203)
- 05000293/LER-1980-052-03, /03L-0:on 800812,while Calibr Reactor Coolant Leak Detection Air Sampling Sys,Particulate Chamber Cover Retaining Nuts Were Stripped.Maint Personnel Replaced Nuts + (ML19343A204)
- ML19343A205 + (ML19343A205)
- ML19343A206 + (ML19343A206)
- ML19343A207 + (ML19343A207)
- ML19343A208 + (ML19343A208)
- 05000333/LER-1980-072, Forwards LER 80-072/03L-0 + (ML19343A209)
- ML19343A210 + (ML19343A210)
- 05000293/LER-1980-051, Forwards LER 80-051/03L-0 + (ML19343A211)
- ML19343A213 + (ML19343A213)
- 05000333/LER-1980-072-03, /03L-0:on 800812,during Plant Startup & Operation, Low Pressure Coolant Injection Inverter Tripped.Caused by Electronic Control Failure.Following Repair,Inverter Became Operable + (ML19343A214)
- 05000293/LER-1980-049, Forwards LER 80-049/03L-0 + (ML19343A215)
- ML19343A216 + (ML19343A216)
- 05000293/LER-1980-051-03, /03L-0:on 800813,while Performing Surveillance Test,Reactor Water Level Instrument L1S 263-72B,switches 3 & 4,exceeded Setpoint Limit.Caused by Setpoint Drift. Instrument Recalibr & Returned to Svc + (ML19343A217)
- ML19343A218 + (ML19343A218)
- ML19343A219 + (ML19343A219)
- ML19343A221 + (ML19343A221)
- ML19343A222 + (ML19343A222)
- 05000336/LER-1980-028-03, /03L-0:on 800811,at 100% Power,Control Element Assembly 41 Dropped from 180 to Zero Steps.Caused by Faulty Jumper Cable from Refuel Disconnect Panel to Reactor Head. Power Reduced & Assembly Realigned.Replacement Planned + (ML19343A223)
- 05000336/LER-1980-029-03, /03L-0:on 800812,during Surveillance Test on 12 U diesel,125 Vdc Ground Alarm Received.Caused by Frayed Insulation on Wire in Bendix Connector Allowing Contact Between Bare Wire & Connector Shell.Wire Recovered + (ML19343A224)