- ML19340B912 + (ML19340B912)
- ML19340B913 + (ML19340B913)
- ML19340B914 + (ML19340B914)
- ML19340B916 + (ML19340B916)
- ML19340B917 + (ML19340B917)
- 05000333/LER-1980-079-03, /03L-0:on 801008,RCIC Sys Made Inoperable to Allow Repair of Steam Leaks on Manual Valves Associated W/Steam Line Drains.Leaks Caused by Normal Aging & Thermal Cycling. Valve Body to Bonnet Gaskets Replaced + (ML19340B918)
- ML19340B919 + (ML19340B919)
- ML19340B921 + (ML19340B921)
- ML19340B922 + (ML19340B922)
- BSEP-80-1748, Confirms 801021 Telcon.On 801020,during Reactor Core Isolation Cooling Flow Controller FIC-03325 Maint,Controller Failed in Automatic Position.Caused by Bad Solder Connection in Printed Circuit.Connection Repaired + (ML19340B923)
- ML19340B924 + (ML19340B924)
- ML19340B925 + (ML19340B925)
- ML19340B926 + (ML19340B926)
- 05000296/LER-1980-041, Forwards LER 80-041/03L-0 + (ML19340B927)
- ML19340B928 + (ML19340B928)
- ML19340B929 + (ML19340B929)
- ML19340B930 + (ML19340B930)
- ML19340B931 + (ML19340B931)
- 05000296/LER-1980-041-03, /03L-0:on 801007,breakers 1918 & 1924 Tripped When Lift Pumps on Cooling Tower 3 started,de-energizing Switchgear B.Caused by Removal of Temp Sensors on Pumps for Maint,Tripping Breakers.Breakers Reclosed + (ML19340B932)
- ML19340B933 + (ML19340B933)
- ML19340B934 + (ML19340B934)
- 05000270/LER-1980-022-01, /01T-0:on 801011,four Holes Were Knocked in Fire Barrier Between Cable Spread Room & Turbine Bldg W/O Establishment of Hourly Fire Watch.Caused by Failure to Provide Proper Notificaion.Hourly Fire Watch Established + (ML19340B937)
- ML19340B938 + (ML19340B938)
- ML19340B939 + (ML19340B939)
- 05000320/LER-1980-035, Discusses LER-80-035/03L-0 Re Failure of Fire Detectors for White Balance of Plant Diesel Generators.Plans to Submit Tech Spec Change Request as Part of Pkg of Multiple Changes + (ML19340B940)
- ML19340B941 + (ML19340B941)
- ML19340B942 + (ML19340B942)
- ML19340B944 + (ML19340B944)
- ML19340B946 + (ML19340B946)
- ML19340B947 + (ML19340B947)
- ML19340B948 + (ML19340B948)
- ML19340B949 + (ML19340B949)
- ML19340B950 + (ML19340B950)
- ML19340B951 + (ML19340B951)
- ML19340B952 + (ML19340B952)
- ML19340B953 + (ML19340B953)
- ML19340B954 + (ML19340B954)
- ML19340B956 + (ML19340B956)
- ML19340B958 + (ML19340B958)
- ML19340B959 + (ML19340B959)
- ML19340B961 + (ML19340B961)
- ML19340B962 + (ML19340B962)
- ML19340B964 + (ML19340B964)
- ML19340B965 + (ML19340B965)
- ML19340B966 + (ML19340B966)
- ML19340B967 + (ML19340B967)
- ML19340B968 + (ML19340B968)
- ML19340B969 + (ML19340B969)
- ML19340B970 + (ML19340B970)
- ML19340B971 + (ML19340B971)
- ML19340B973 + (ML19340B973)