Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19332A973 + (ML19332A973)
- ML19332A974 + (ML19332A974)
- ML19332A975 + (ML19332A975)
- ML19332A977 + (ML19332A977)
- ML19332A979 + (ML19332A979)
- ML19332A980 + (ML19332A980)
- ML19332A981 + (ML19332A981)
- ML19332A982 + (ML19332A982)
- ML19332A983 + (ML19332A983)
- IR 05000354/1980004 + (ML19332A984)
- ML19332A986 + (ML19332A986)
- IR 05000382/1980018 + (ML19332A988)
- ML19332A989 + (ML19332A989)
- ML19332A990 + (ML19332A990)
- ML19332A991 + (ML19332A991)
- ML19332A992 + (ML19332A992)
- ML19332A993 + (ML19332A993)
- ML19332A994 + (ML19332A994)
- ML19332A995 + (ML19332A995)
- 05000296/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19332A996)
- ML19332A997 + (ML19332A997)
- 05000296/LER-1980-033-03, /03L-0:on 800815,during Normal Operation at Steady State Power,Unit 2B & 2D RHR Heat Exchanger Radiation Alarm Was Received.Probably Caused by Leaking Gasket Due to Loose Flange Nuts Resulting from Thermal Cycling & Vibratio + (ML19332A998)
- ML19332A999 + (ML19332A999)
- ML19332B000 + (ML19332B000)
- ML19332B001 + (ML19332B001)
- ML19332B003 + (ML19332B003)
- ML19332B004 + (ML19332B004)
- 05000259/LER-1980-060, Forwards LER 80-060/03L-0 + (ML19332B007)
- ML19332B008 + (ML19332B008)
- 05000259/LER-1980-061, Forwards LER 80-061/03L-0 + (ML19332B009)
- ML19332B010 + (ML19332B010)
- ML19332B011 + (ML19332B011)
- 05000327/LER-1980-141, Forwards LER 80-141/01T-0 + (ML19332B013)
- ML19332B014 + (ML19332B014)
- 05000278/LER-1980-020-03, /03L-0:on 800815,while Performing Leak Test, Containment Ventilation Valve AO-3521B Was Found Leaking Excessively.Caused by Valve T-ring Inflating Before Closure.Air Valves Adjusted & Valve Tested + (ML19332B015)
- 05000333/LER-1980-073, Forwards LER 80-073/03L-0 + (ML19332B016)
- ML19332B017 + (ML19332B017)
- 05000333/LER-1980-073-03, /03L-0:on 800815 During Surveillance,Offgas Radiation Monitor B Found Out of Calibr.Caused by Instrument Drift & Detector Aging.Adjusted & Restored Monitor to Operable Status 3 Days After Discovery + (ML19332B018)
- 05000327/LER-1980-141-01, /01T-0:on 800829,while in Mode 5,pinhole Leak Was Discovered in Rod travel-housing Latch Housing Interface Seal Weld on Control Rod Drive Mechanism C-11.Cause Not Stated.Fault to Be Ground Out & Weld Repaired + (ML19332B019)
- 05000259/LER-1980-061-03, /03L-0:on 800814,during Normal Operation,Thermal Overload on 1A Residual Heat Removal Area Cooler Fan Breaker Tripped.Caused by Thermal Overload Being Improperly Set. Overload Reset & Properly Adjusted + (ML19332B020)
- 05000259/LER-1980-060-03, /03L-0:on 800814,during Normal Operation,B Core Spray Pump Area Cooler Fan Thermostat TS-64-73 Setting Was Above Tech Spec Limit.Caused by Setpoint Being Moved. Thermostat Reset.Caution Signs Posted to Prevent Recurrence + (ML19332B021)
- 05000327/LER-1980-154, Forwards LER 80-154/03L-0 + (ML19332B024)
- ML19332B025 + (ML19332B025)
- ML19332B027 + (ML19332B027)
- 05000327/LER-1980-154-03, /03L-0:on 800815,auxiliary Bldg Vent Radiation Monitor O-RM-90-101B Did Not Respond to Check Source.Caused by Short in 24-volt Power Supply & Detector Preamplifier + (ML19332B028)
- ML19332B029 + (ML19332B029)
- ML19332B030 + (ML19332B030)
- ML19332B031 + (ML19332B031)
- ML19332B032 + (ML19332B032)
- ML19332B033 + (ML19332B033)
- PNO-I-80-126, on 800908,picket Line Was Set Up at Station Entrance.Licensed Operators Are Honoring Picket Line.Shift Staffing Plan Prepared Using Supervisory Personnel + (ML19332B034)