Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19330A871 + (ML19330A871)
- 05000282/LER-1980-019-03, /03L-0:on 800630,two Power Range High Power Trip Setpoints Were Over Tech Spec Limit.Caused by Personnel Error.Rept Reviewed & Technicians Cautioned + (ML19330A872)
- ML19330A873 + (ML19330A873)
- ML19330A874 + (ML19330A874)
- 05000327/LER-1980-109-03, /03L-0:on 800626,during SI-166,containment Spray Pump Discharge Check valve,1 A-A,found to Leak Excessively. Caused by Valve Leaking Through.Pump Removed from Svc & Valve Repaired + (ML19330A875)
- 05000327/LER-1980-110, Forwards LER 80-110/03L-0 + (ML19330A876)
- ML19330A877 + (ML19330A877)
- ML19330A878 + (ML19330A878)
- ML19330A879 + (ML19330A879)
- ML19330A880 + (ML19330A880)
- ML19330A881 + (ML19330A881)
- 05000327/LER-1980-110-03, /03L-0:on 800625,main Steam Flow loop,1-F-28A, Declared Inoperable Due to Maint Requiring Removal of Loop from Svc.Caused by Loop Current Disturbance.Loop Functioned Properly W/O Test Recorder & Return to Svc + (ML19330A882)
- ML19330A883 + (ML19330A883)
- ML19330A884 + (ML19330A884)
- ML19330A885 + (ML19330A885)
- ML19330A886 + (ML19330A886)
- ML19330A888 + (ML19330A888)
- ML19330A890 + (ML19330A890)
- ML19330A891 + (ML19330A891)
- ML19330A892 + (ML19330A892)
- 05000327/LER-1980-111, Forwards LER 80-111/03L-0 + (ML19330A893)
- ML19330A894 + (ML19330A894)
- ML19330A895 + (ML19330A895)
- AECM-80-163, Provides Status of Potentially Reportable Deficiency Re Loss of Offsite Power Accident & Effects on Rod Position Sys & Neutron Monitoring Sys.Deficiency Still Under Investigation.Final Rept Will Be Provided by 801230 + (ML19330A898)
- 05000327/LER-1980-111-03, /03L-0:on 800626,during Normal operation,1-FCV-62- 136 (B Train to Suction of Charging Pump from RWST) Would Not Open from Main Control Room.Caused by Valve Operator Torque Spring Being Out of Adjustment.Spring Readjusted + (ML19330A899)
- ML19330A900 + (ML19330A900)
- ML19330A901 + (ML19330A901)
- ML19330A902 + (ML19330A902)
- ML19330A903 + (ML19330A903)
- ML19330A904 + (ML19330A904)
- ML19330A905 + (ML19330A905)
- ML19330A906 + (ML19330A906)
- 05000259/LER-1980-052, Forwards LER 80-052/03L-0 + (ML19330A907)
- ML19330A908 + (ML19330A908)
- ML19330A909 + (ML19330A909)
- 05000259/LER-1980-052-03, /03L-0:on 800628,during Normal operation,4kV SD Bd B Tripped on Degraded Voltage,Initiating Auto Start of Diesel Generator B.Diesel Generator Tripped Again on Degraded Voltage.Caused by Improper Switch Alignment + (ML19330A910)
- ML19330A911 + (ML19330A911)
- ML19330A912 + (ML19330A912)
- ML19330A913 + (ML19330A913)
- ML19330A914 + (ML19330A914)
- ML19330A915 + (ML19330A915)
- ML19330A916 + (ML19330A916)
- 05000327/LER-1980-108, Forwards LER 80-108/03L-0 + (ML19330A917)
- ML19330A918 + (ML19330A918)
- ML19330A919 + (ML19330A919)
- 05000327/LER-1980-108-03, /03L-0:on 800624,during Normal Operations,Fuse in Switching Bridge Circuit Failed on Vital Inverter 2-I Which Rendered 120 Volt Ac Vital Instrument Power Board 2-I Inoperable.Cause Unknown.Fuse Replaced + (ML19330A920)
- ML19330A921 + (ML19330A921)
- ML19330A923 + (ML19330A923)
- ML19330A924 + (ML19330A924)
- ML19330A925 + (ML19330A925)
- ML19330A926 + (ML19330A926)