- 05000321/LER-1980-047, Forwards LER 80-047/03L-0 + (ML19323G964)
- ML19323G965 + (ML19323G965)
- ML19323G966 + (ML19323G966)
- ML19323G967 + (ML19323G967)
- ML19323G968 + (ML19323G968)
- 05000321/LER-1980-047-03, /03L-0:on 800404,during Review of Normal Surveillance Testing Data Sheets,Rhr Pumps a & C Flow Rate Did Not Meet Tech Spec Requirements.Cause Not Stated.Rhr Pump Surveillance Procedure Will Be Revised + (ML19323G969)
- ML19323G970 + (ML19323G970)
- ML19323G971 + (ML19323G971)
- ML19323G972 + (ML19323G972)
- ML19323G973 + (ML19323G973)
- ML19323G974 + (ML19323G974)
- 05000317/LER-1980-027, Forwards LER 80-027/01T-0 + (ML19323G975)
- ML19323G976 + (ML19323G976)
- ML19323G977 + (ML19323G977)
- 05000317/LER-1980-027-01, /01T-0:on 800520,following Routine Tube Cleaning on Saltwater Side of Svc Water Heat Exchanger 12,low Pressure Alarms Were Received on Subsys 11 & 12.Caused by Failed Tube in Exchanger 11 Instrument Compressor Cooler + (ML19323G978)
- 05000324/LER-1980-043, Forwards LER 80-043/03L-0 + (ML19323G979)
- ML19323G980 + (ML19323G980)
- ML19323G981 + (ML19323G981)
- 05000309/LER-1980-012, Forwards LER 80-012/03L-0 + (ML19323G982)
- 05000324/LER-1980-043-03, /03L-0:on 800507,during Current Refueling Outage, Standby Gas Treatment Operability Test Was Not Performed by Required 800425 Date.Caused by Administrative Oversight. Satisfactorily Performed on 800507 + (ML19323G984)
- ML19323G985 + (ML19323G985)
- ML19323G986 + (ML19323G986)
- 05000309/LER-1980-012-03, /03L-0:on 800506,during Monthly Surveillance Test Procedure,Low Power Safety Injection Loop 3 Header Stop Valve Failed to Operate as Required.Caused by Broken Weld in Coupling of Operating Extension Shaft + (ML19323G987)
- 05000338/LER-1980-047, Forwards LER 80-047/01T-0 + (ML19323G988)
- ML19323G989 + (ML19323G989)
- 05000338/LER-1980-047-01, /01T-0:on 800523,safety Injection Occurred Due to High Steam Line Flow Signal Coincident w/lo-lo Tave.Caused by Loss of Vital Bus 1-III Which Removes Power from Feedwater Flow/Steam Flow Comparators for Steam Generators + (ML19323G990)
- ML19323G991 + (ML19323G991)
- 05000317/LER-1980-026, Forwards LER 80-026/01T-0 + (ML19323G992)
- ML19323G993 + (ML19323G993)
- 05000317/LER-1980-026-01, /01T-0:on 800520,while in Hot Standby,Realignment of Condensate Storage Tank Header Supply Valves Resulted in Isolation of Water Supply to Auxiliary Feedwater Pumps. Caused by Error of Transposed Valve Numbers in Log + (ML19323G994)
- ML19323G995 + (ML19323G995)
- ML19323G996 + (ML19323G996)
- ML19323G997 + (ML19323G997)
- 05000344/LER-1980-008, Forwards LER 80-008/01T-0 + (ML19323G999)
- 05000334/LER-1980-032-03, /03L-0:on 800503,during Control Board Insp,Vol Control Tank Outlet Valve Was Found Shut.Caused by Short Circuited Lead in Level Comparator.Shorted Wire Replaced + (ML19323H001)
- 05000344/LER-1980-008-01, /01T-0:on 800516,during Refueling Operations, Discovered That Containment Integrity Was Breached.Caused by Personnel Error.Two Separate Maint Activities Were Being Performed W/No Coordination + (ML19323H002)
- 05000334/LER-1980-028-03, /03L-0:on 800504,power Was Lost to Vital Bus Inverter 4 Due to Blown Main Power Supply Fuse.Cause Unknown.Fuse & Rectifier Replaced.Frequency Adjusted + (ML19323H003)