Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19320C018 + (ML19320C018)
- ML19320C019 + (ML19320C019)
- 05000325/LER-1980-053, Forwards LER 80-053/03L-0 + (ML19320C020)
- ML19320C021 + (ML19320C021)
- ML19320C022 + (ML19320C022)
- ML19320C023 + (ML19320C023)
- ML19320C024 + (ML19320C024)
- ML19320C025 + (ML19320C025)
- 05000368/LER-1980-041-03, /03L-0:on 800610,during Mode 1 Operation,Plant Computer Was Taken Out of Svc Rendering COLSS Inoperable. Computer Was Taken Out of Svc to Troubleshoot Problem Re CRT Displays.Backup Plant Computer Will Be Installed + (ML19320C026)
- ML19320C027 + (ML19320C027)
- ML19320C028 + (ML19320C028)
- ML19320C029 + (ML19320C029)
- ML19320C030 + (ML19320C030)
- 05000325/LER-1980-053-03, /03L-0:on 800607,during Normal Reactor Bldg Tour During Refueling,Inner & Outer Doors of 50-ft Air Lock Found Open.Caused by Burned Coil in Inner Door Interlock Solenoid. Coil Replaced & Air Lock Access Restored + (ML19320C031)
- 05000321/LER-1980-066, Forwards LER 80-066/03L-0 + (ML19320C032)
- ML19320C033 + (ML19320C033)
- ML19320C034 + (ML19320C034)
- ML19320C035 + (ML19320C035)
- ML19320C036 + (ML19320C036)
- 05000321/LER-1980-066-03, /03L-0:on 800615,diesel Generator 1C Declared Inoperable When Low Air Pressure Alarm Received W/Reactor in Run Mode.Caused by Valves Failing in Unloaded Mode.Unloader Valves Replaced & Air Receivers Returned to Proper Pressu + (ML19320C037)
- ML19320C038 + (ML19320C038)
- 05000366/LER-1980-095, Forwards LER 80-095/03L-0 + (ML19320C039)
- ML19320C040 + (ML19320C040)
- ML19320C041 + (ML19320C041)
- 05000368/LER-1980-039, Forwards LER 80-039/03L-0 + (ML19320C042)
- ML19320C043 + (ML19320C043)
- 05000338/LER-1980-057, Forwards LER 80-057/03L-0 + (ML19320C044)
- ML19320C045 + (ML19320C045)
- 05000267/LER-1979-063, Has Been Cancelled + (ML19320C046)
- ML19320C047 + (ML19320C047)
- 05000368/LER-1980-039-03, /03L-0:on 800610,during Mode 1 Operation,Steam Driven Emergency Feedwater Pump 2P7A Would Not Accelerate Above 1,000 Rpm After Successful Start.Caused by Incorrectly Wired Lead from Ramp Generator to Egm Governor + (ML19320C048)
- 05000368/LER-1979-100, Has Been Cancelled + (ML19320C049)
- ML19320C050 + (ML19320C050)
- ML19320C051 + (ML19320C051)
- ML19320C052 + (ML19320C052)
- 05000338/LER-1980-057-03, /03L-0:on 800618,during Mode 2 Operation,Greater than Twelve Step Disagreement Was Noted Between Individual & Group Position Indication for Rod G-9.Caused by Voltage Drift in Signal Conditioning Card + (ML19320C053)
- 05000298/LER-1979-031, Has Been Cancelled + (ML19320C054)
- ML19320C055 + (ML19320C055)
- ML19320C056 + (ML19320C056)
- ML19320C057 + (ML19320C057)
- 05000333/LER-1980-056, Forwards LER 80-056/03L-0 + (ML19320C058)
- ML19320C059 + (ML19320C059)
- ML19320C060 + (ML19320C060)
- ML19320C061 + (ML19320C061)
- ML19320C062 + (ML19320C062)
- ML19320C063 + (ML19320C063)
- ML19320C064 + (ML19320C064)
- ML19320C065 + (ML19320C065)
- 05000333/LER-1980-056-03, /03L-0:on 800610,during Normal Shutdown & Surveillance Testing,Emergency Diesel Generator C Tripped on High Circulating Current.Caused by Dirty or Defective Contact on Voltage Regulator Droop Switch + (ML19320C066)
- ML19320C067 + (ML19320C067)
- ML19320C068 + (ML19320C068)