List of results
- ML19305B982 + (ML19305B982)
- ML19305B983 + (ML19305B983)
- ML19305B984 + (ML19305B984)
- ML19305B985 + (ML19305B985)
- ML19305B986 + (ML19305B986)
- ML19305B987 + (ML19305B987)
- ML19305B990 + (ML19305B990)
- ML19305B991 + (ML19305B991)
- ML19305B992 + (ML19305B992)
- ML19305B993 + (ML19305B993)
- ML19305B995 + (ML19305B995)
- 05000155/LER-1980-007, Forwards LER 80-007/03L-0 + (ML19305B998)
- ML19305C000 + (ML19305C000)
- 05000155/LER-1980-007-03, /03L-0:on 800224,during Routine Operation,Excess Vibration Was Noted on Control Rod Drive Pump 2.Caused by Worn Suction Poppet Valves on Pump & Damage to Pump Piping Hangers from Vibration.Valves Replaced & Hangars Repaired + (ML19305C002)
- ML19305C003 + (ML19305C003)
- ML19305C005 + (ML19305C005)
- 05000324/LER-1980-026, Forwards LER 80-026/03L-0 + (ML19305C006)
- ML19305C008 + (ML19305C008)
- ML19305C009 + (ML19305C009)
- ML19305C010 + (ML19305C010)
- ML19305C011 + (ML19305C011)
- ML19305C012 + (ML19305C012)
- 05000324/LER-1980-026-03, /03L-0:on 800225,while Performing HPCI Steamline High Differential Pressure Channel Calibr and Functional Check,Main Streamline High Flow Instrument 2E41-DPIS-NOO4 Found Out of Tolerance.Caused by Setpoint Drift + (ML19305C014)
- ML19305C016 + (ML19305C016)
- ML19305C020 + (ML19305C020)
- ML19305C021 + (ML19305C021)
- ML19305C027 + (ML19305C027)
- ML19305C028 + (ML19305C028)
- ML19305C029 + (ML19305C029)
- ML19305C030 + (ML19305C030)
- ML19305C031 + (ML19305C031)
- 05000267/LER-1980-008, Forwards LER 80-008/03L-0 + (ML19305C032)
- ML19305C033 + (ML19305C033)
- 05000325/LER-1980-006, Forwards LER 80-006/03L-0 + (ML19305C034)
- ML19305C035 + (ML19305C035)
- ML19305C036 + (ML19305C036)
- 05000267/LER-1980-008-03, /03L-0:on 800219,during Routine Surveillance Testing,Setpoints for Low Flow on One Dewpoint Moisture Monitor & for Fixed low-low Flow on Another Monitor Found Less than Min Acceptable.Caused by Instrument Calibr Drift + (ML19305C037)
- 05000325/LER-1980-006-03, /03L-0:on 800225,while Working on Trouble Ticket Re Position Indication for RIP Valve 49B,discovered Valve Not Closing Fully When Given Closing Signal.No Cause Stated. Valve Will Be Repaired During 1980 Refueling Outage + (ML19305C038)
- ML19305C039 + (ML19305C039)
- ML19305C040 + (ML19305C040)
- ML19305C042 + (ML19305C042)
- ML19305C043 + (ML19305C043)
- ML19305C046 + (ML19305C046)
- ML19305C047 + (ML19305C047)
- ML19305C048 + (ML19305C048)
- ML19305C049 + (ML19305C049)
- ML19305C050 + (ML19305C050)
- ML19305C051 + (ML19305C051)
- ML19305C053 + (ML19305C053)
- ML19305C054 + (ML19305C054)
- ML19305C055 + (ML19305C055)