- ML19262A914 + (ML19262A914)
- 05000293/LER-1979-043, Forwards LER 79-043/03L-0 + (ML19262A915)
- ML19262A916 + (ML19262A916)
- 05000293/LER-1979-043-03, /03L-0:on 791108,drywell Unidentified Leakage Rate Exceeded Tech Specs.Caused by Leakage Passing Inboard Isolation Valve MO-2301-4 on HPCI Sys.Valve Backseated & Leakage Reduced to Less than That Requiring Shutdown + (ML19262A917)
- ML19262A918 + (ML19262A918)
- 05000219/LER-1979-042, Forwards LER 79-042/03L-0 + (ML19262A919)
- ML19262A920 + (ML19262A920)
- ML19262A921 + (ML19262A921)
- 05000219/LER-1979-042-03, /03L-0:on 791106,valve ERV Nr 108A Opened During Operation for No Reason.After Calibr,Valve Malfunctioned within 1-h.Caused by Component Failure.Pressure Switch Replaced + (ML19262A922)
- ML19262A923 + (ML19262A923)
- ML19262A924 + (ML19262A924)
- 05000321/LER-1979-091, Forwards LER 79-091/03L-0 + (ML19262A925)
- ML19262A926 + (ML19262A926)
- 05000321/LER-1979-091-03, /03L-0:on 791106,insurance Investigation Revealed Required Penetration Seal Not Installed in 2-inch Penetration in Control/Svc Bldg Firewall.Caused by Misinterpreted Drawings.Seal Installed + (ML19262A927)
- 05000312/LER-1979-003, Forwards LER 79-003/04T-0 + (ML19262A928)
- 05000312/LER-1979-003-04, /04T-0:on 791120,plant Effluent Sample Exceeded Tech Spec Limit of 0.2 Mg/L Chlorine.Caused by Excessive Flow in Plant Sewage Sys + (ML19262A930)
- 05000333/LER-1979-100, Forwards LER 79-100/03L-0 + (ML19262A931)
- ML19262A932 + (ML19262A932)
- 05000333/LER-1979-100-03, /03L-0:on 791108,during Normal Operation to Complete Corrective Maint,Hpci Sys Unintentionally Made Inoperable.Caused by Need to Replace Leaking Gasket Associated W/Sys Hydraulic Control Valve Seat Drain + (ML19262A933)
- 05000302/LER-1979-105, Forwards LER 79-105/03L-0 + (ML19262A934)
- ML19262A935 + (ML19262A935)
- 05000302/LER-1979-105-03, /03L-0:on 791101,during Sampling of Rcs,Chemical Addition Isolation Valve CAV-2 Would Not Close.Cause Unknown.Valve Body of CAV-2 Lubricated,Satisfactorily Tested & Returned to Svc on 791102 + (ML19262A936)
- ML19262A937 + (ML19262A937)
- ML19262A938 + (ML19262A938)
- 05000348/LER-1979-050-03, /03L-0:on 791107,trip Bistables for Pressurizer Pressure Transmitter PT455 Not Tripped Before Pressurizer Level Transmitter 459 Root Valves Closed.Caused by Personnel Error.Matter to Be Discussed W/Operations Personnel + (ML19262A939)
- 05000348/LER-1979-051-03, /03L-0:on 791103,during Surveillance Test on Turbine Driven Auxiliary Feedwater Pump,Pump Tripped on Overspeed.Caused by Misadjustment of Manual Speed Due to Leak of Position Markings.Manual Control Adjusted + (ML19262A940)
- 05000348/LER-1979-052-03, /03L-0:on 791106,refueling Water Storage Tank Declared Inoperable When Water Vol Fell Below Tech Specs. Caused by Drift Problems on Level Transmitters.Transmitters Undergoing Repairs + (ML19262A941)
- 05000348/LER-1979-054-01, /01T-0:on 791119,notified by Westinghouse That Possibility Exists That Current Negative Rate Trip Setpoints May Not Provide Reactor Trip During Single or Multiple Rod Drop Events.Caused by Designer Calculation Errors + (ML19262A942)
- ML19262A945 + (ML19262A945)
- 05000333/LER-1979-099, Forwards LER 79-099/03L-0 + (ML19262A946)
- ML19262A947 + (ML19262A947)
- ML19262A948 + (ML19262A948)
- ML19262A949 + (ML19262A949)
- 05000333/LER-1979-099-03, /03L-0:on 791105,leaking Access Plug on Hydraulic Control Unit for Control Rod 18-35 Required Unit to Be Isolated,Making Control Rod Inoperable.Caused by Failed O-ring.Ring Replaced + (ML19262A950)
- ML19262A951 + (ML19262A951)
- ML19262A952 + (ML19262A952)
- ML19262A954 + (ML19262A954)
- 05000333/LER-1979-102, Forwards LER 79-102/03L-0 + (ML19262A956)
- ML19262A957 + (ML19262A957)
- ML19262A958 + (ML19262A958)
- ML19262A959 + (ML19262A959)
- ML19262A960 + (ML19262A960)
- 05000333/LER-1979-102-03, /03L-0:on 791108,reactor Water Conductivity Exceeded Tech Spec Limit.Caused by Decomposition of Ion Exchange Resins Which Altered Ph Level.Eight Condenser Tubes Plugged & One Condensate Demineralizer Removed + (ML19262A961)
- 05000285/LER-1979-020, Forwards LER 79-020/03L-0 + (ML19262A962)
- ML19262A963 + (ML19262A963)
- ML19262A964 + (ML19262A964)
- ML19262A965 + (ML19262A965)
- ML19262A966 + (ML19262A966)
- ML19262A967 + (ML19262A967)
- ML19262A968 + (ML19262A968)
- 05000285/LER-1979-020-03, /03L-0:on 791031,during Insps of Accessible Piping,Eight Snubbers on Safety Injection Sys Piping Found Inoperable.Caused by Improper Installation of Anchor Bolts. Base Plate Redesigned & Anchor Bolts Reinstalled + (ML19262A969)