ML19262A967

From kanterella
Jump to navigation Jump to search
Forwards Interim Deficiency Rept Re Broken Anchor Bolt in Reactor Vessel Support Skirt Flange
ML19262A967
Person / Time
Site: Midland
Issue date: 12/14/1979
From: Howell S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19262A968 List:
References
HOWE-311-79, NUDOCS 7912110365
Download: ML19262A967 (1)


Text

.

Consumers

@ Power C0@Hny Sa"*" " "'* *"

Senior Vice Presidens General Offices: 1945 We,t Pernait Road, Jackson, Michigan 49201 * (517) 7884453 December 4l' ,1979 Hove-311-79

/r J G Keppler, Regional Director Office of Inspection and Enforcement US Nuclear Regulatory Cc==ission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 MIDLAND NUCLEAR PLANT UNIT NO 1, DOCKET NO 50-329 UNIT NO 2, DOCKET N0 50-330 UNIT NO 1, REACTOR VESSEL ERCKEN ANCHOR BOLT

Reference:

Letter SHHowell to JGKeppler; Midland Nuclear Plant; Unit No 1, Decket No 50-329; Unit No 2, Decke: No 50-330; Unit No 1 Reactor Vessel Broken Anchor Bolt; Heve-267-79; dated October 12, 1979 This letter, as was the referenced letter, is an interi: 50.55(e) report concerning the brchen anchor belt in the Unit I reactor vessel support

. skirt flange. The attachment to this letter provides a status of the actions being taken to resolve this condition.

Another r'eport, either interi: cr final, vill be sent en or before March 3, 1980.

WRB/1r

Attachment:

Eroken Reacter Vessel Anchor Bolt in Unit 1 Status Report, dated December 5, 1979 CC: Director of Office of Inspection & Enforcement Att: Mr Victor Stello, USNRC (15)

Director, Office of Manage =ent Information and Program Centrol, USNRC (1) ~

0 h.I p.

9I I 7912110 3 d 4