Confirms 791119 Notification of Implemented Mod.Automatic Rod Control Operation Prohibited Above 90% of Rated Power W/Control Bank D Below 216 Steps Withdrawn
ML19262A923
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 12/04/1979
From: Peoples D
COMMONWEALTH EDISON CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 7912110318
Download: ML19262A923 (1)


Text

Commonwealth Edison One First National Plaza. ChicagoJinois Address Reply to: Post Office Box 767 Chicago 11hnois 60690 December 4, 1979 Dr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Zion Station Units 1 and 2 Protection Against Dropped Rods NRC Docket Nos. 50-295 and 50-304

Dear Dr. Denton:

On Monday, November 19, 1979, the NRC Staff met in Bethesda with Westinghouse and numerous utility representatives including Commonwealth Edison Company to discuss Westinghouse Electric Corporation's Notification of Reportable Item (Dropped Rod).

From this discussion, the potential safety concerns associated with multiple dropped rods could be alleviated on an interim basis by prohibiting automatic rod control operation above 90% of rated power with Control Bank D (CBD) below 216 steps withdrawn.

As a result, the NRC Staff required within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> notification of compliance with this interim fix.

On November 21, 1979, verbal notification was made to the NRC Staff that Commonwealth Edison had implemented the proposed fix.

This letter provides formal confirmation that the Zion Station procedures have been modified to prohibit automatic rod control operation above 90% of rated power with CBD below 216 steps withdrawn.

Please address any questions that you might have concerning this matter to this office.

One (1) signed original and thirty-nine (39) copies of this letter are provided for your use.

Very truly yours, b.

l

><f;,

D. L. Peoples Director of Nuclear Licensing WFN:mae 15280$$

7 912110 3 lT