- 05000289/LER-1977-023, RO 77-23/1T:on 770920,both Doors of Reactor Bldg Emergency Personnel Access Hatch Open Simultaneously.Caused by Personnel Error.Doors Closed.Forwards LER 77-23/1T + (ML19261F309)
- ML19261F310 + (ML19261F310)
- 05000289/LER-1977-023-01, /01T:on 770926,during Heatup Operation Both Doors of Reactor Bldg Emergency Personnel Access Hatch Open Simultaneously.Caused by Failure of Interlock,Poor Hatch Design & Operator Error.Addl Interlock to Be Added + (ML19261F311)
- ML19261F312 + (ML19261F312)
- ML19261F313 + (ML19261F313)
- ML19261F314 + (ML19261F314)
- 05000289/LER-1977-022-01, /01T:on 770825,during Normal Operation Restrictions Placed on Decay Heat Removal Pumps Found Contrary to Pump Operating Capability Per Fsar.Restrictions Placed on Pump by B&W Due to Pump Failure at Other Util + (ML19261F315)
- ML19261F316 + (ML19261F316)
- ML19261F317 + (ML19261F317)
- 05000289/LER-1977-019-03, /03L:on 770713,during Normal Operation,Leak in Miscellaneous Waste Evaporator Feed Tank Immersion Heater Shorted Out Heater & Feed Pump.Caused by Leak in Temp Probe on Heater.Heater Replaced & Operating Procedure Modified + (ML19261F318)
- ML19261F319 + (ML19261F319)
- ML19261F320 + (ML19261F320)
- 05000289/LER-1977-021-01, /01T:on 770726,during Normal Operation,Radiation Monitor RM-A2 Failed & Atmosphere Sampling of Reactor Bldg Not Performed.Caused by Improper Reassembly Following 770725 Surveillance Test.Monitor Repaired.Procedure to Be Revi + (ML19261F321)
- ML19261F322 + (ML19261F322)
- ML19261F323 + (ML19261F323)
- 05000289/LER-1977-018-03, /03L:on 770629,during Normal Operation,Nuclear Svcs River Water Pump NR-P1C Shaft Failed During Pump Operation.Caused by Mechanical & Procedural Problems.Pump Lined Up & Repaired within 4-h + (ML19261F324)
- ML19261F325 + (ML19261F325)
- ML19261F326 + (ML19261F326)
- 05000289/LER-1977-017-03, /03L:on 770624,during Normal Operating & semi- Annual Leak Test,Leakage Observed Around Inner Door Seal of Personnel Accces Hatch of Reactor Bldg.Caused by Procedural Inadequacies Causing Improper Installation of Door + (ML19261F327)
- 05000289/LER-1977-015, Notes Error in LER 77-15/3L Submitted 770628.Both Drawings in Section 9 Should Be Numbered 207-011 + (ML19261F328)
- ML19261F329 + (ML19261F329)
- ML19261F330 + (ML19261F330)
- ML19261F331 + (ML19261F331)
- 05000289/LER-1977-015-03, /03L:on 770529,during Normal operation,230 Kv Substation Bus 4 Was de-energized by Differential Relay 87BB-1.Caused by Wiring Error on Auxiliary Transformer Due to Drawing Error.Bus & Transformer Returned to Svc + (ML19261F332)
- ML19261F333 + (ML19261F333)
- ML19261F334 + (ML19261F334)
- 05000289/LER-1977-014-03, /03L:on 770524,during Reactor Bldg Cooling & Isolation Sys Logic Channel & Component Test,Reactor Bldg Cooling Return Isolation Valve RB-V7 Failed to Close Upon Receipt of Signal.Caused by Dirt on Valve Diaphragm + (ML19261F335)
- 05000289/LER-1977-012, RO 77-12/3L:on 770519,engineered Safeguard Pump MU-P-1A Was Removed from Svc Prior to Testing Operability of Redundant Pump.Caused by Personnel Error.Redundant Pump Tested Satisfactorily on 770519.Forwards LER 77-12/03L + (ML19261F336)
- ML19261F337 + (ML19261F337)
- 05000289/LER-1977-012-03, /03L:on 770519,engineered Safeguard Pump MU-P-1A Was Removed from Svc Prior to Testing Redundant Pump. Caused by Personnel Error.Redundant Pump Tested Satisfactorily.Personnel Instructed in Procedures + (ML19261F338)
- ML19261F339 + (ML19261F339)
- ML19261F340 + (ML19261F340)
- 05000289/LER-1977-013-04, /04T:on 770523,during Normal Operation,Waste Concentration in River Water Discharge Found in Excess of Designated Max.Caused by Slug of Suspended Solids Breaking Loose During Sampling.Discharge Terminated + (ML19261F341)