\\ y.... ~.~.,,,

, g METROPOLITAN EDl SON COMPANY sussroisavor aturnatruwconuntscwonarion ST OFFICE BOX 480 MIDD LETOWN. PENNSYLV ANI A 17057 TEtEPHONE 717 944 4041 19 December 1977 Mr. Boyce H. Grier Directorate of Regulatory Operations D**g q'q q aq[f,} l'.! l p

Region I g

a Nuclear Regulatory Commissiton 631 Park Avenuo King of Prussia, Pennsylvania 19406

~

Operating License DPR-50 Docket 50-289

Subject:

Reportable Occurrence No. 77-29/IP

Dear Mr. Grier:

This telegram is to confirm the telecon between Mr.

G..

A.

Kunder, Unit I Superintendent, Technical Support, and Mr.

P. J. Kellogg, Region I-NRC at 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> on 16 December 1977.-

In accordance with Technical Specification 6.9.2.A.8, we are re-porting that an error was found in the methods used for calculating the volume of boron required to bring the reactor to a cold shutdo...

condition as required by Technical Specification 3.2.

On 16 December 1977, Metropolitan Edison. Company was informed by the NSS supplier, B&W, that the volume required by Technical Specifica-tions was insufficient to bring the reactor to a cold shutdown condition and that 776 ft3 of 8700 ppm boron. or equivalent would be required to meet the bases of Technical Specification 3.2.

Upon receipt of this infor: nation TMI-I immediately increased thethan theequivalentof776ftgencentratedboricacidsolutiontogreater volume of the source of of 8700 ppm boron.

Further corrective action will be discussed in the followup report.

Very truly yours, Relk i

p. O'Hanlon f

Unit I Superintendent kk JPO/ job

~

\\

9 0

  1. 91025g k$