- 05000325/LER-1979-112, Forwards LER 79-112/03L-0 + (ML19257B258)
- ML19257B259 + (ML19257B259)
- 05000325/LER-1979-112-03, /03L-0:on 791219,during Normal Reactor Startup, Indication 3 in Tens Digit for Control Rod 42-07 Did Not Light from 30 to 39.Caused by Short to Ground in Position Indicating Probe.Problem Will Be Corrected at Next Outage + (ML19257B260)
- 05000317/LER-1979-079, Forwards LER 79-079/03L-0 + (ML19257B261)
- ML19257B262 + (ML19257B262)
- ML19257B263 + (ML19257B263)
- 05000317/LER-1979-079-03, /03L-0:on 791219,high Differential Pressure Detected Across Filters of Fuel Pool Exhaust Fans.Caused by Excessive Buildup of Dirt on Filter Media.Maint Procedure 1-32-M-M-3 Initiated to Inspect Filters Monthly + (ML19257B264)
- ML19257B265 + (ML19257B265)
- ML19257B266 + (ML19257B266)
- ML19257B267 + (ML19257B267)
- ML19257B268 + (ML19257B268)
- 05000254/LER-1979-042, Forwards LER 79-042/03L-0 + (ML19257B269)
- ML19257B270 + (ML19257B270)
- ML19257B271 + (ML19257B271)
- ML19257B272 + (ML19257B272)
- 05000254/LER-1979-042-03, /03L-0:on 791214,while Performing MSIV Closure Timing Surveillance,Ao 1-203-1C Found to Close in 5.2-s. Caused by Varied Speed Control Valve Adjustment on Hydraulic Control Cylinder.Valve Adjusted + (ML19257B273)
- ML19257B274 + (ML19257B274)
- ML19257B275 + (ML19257B275)
- ML19257B276 + (ML19257B276)
- ML19257B277 + (ML19257B277)
- ML19257B278 + (ML19257B278)
- ML19257B280 + (ML19257B280)
- ML19257B281 + (ML19257B281)
- ML19257B283 + (ML19257B283)
- ML19257B285 + (ML19257B285)
- ML19257B286 + (ML19257B286)
- ML19257B287 + (ML19257B287)
- ML19257B288 + (ML19257B288)
- ML19257B289 + (ML19257B289)
- ML19257B290 + (ML19257B290)
- ML19257B291 + (ML19257B291)
- AECM-79-148, Requests Response to 790710 & 0912 Requests to Delete Stage Monitoring Requirement in Environ Protection Program + (ML19257B292)
- ML19257B293 + (ML19257B293)
- ML19257B294 + (ML19257B294)
- 05000366/LER-1979-136, Forwards LER 79-136/03L-0 + (ML19257B295)
- ML19257B296 + (ML19257B296)
- 05000344/LER-1979-016, Forwards LER 79-016/03L-0 + (ML19257B297)
- ML19257B299 + (ML19257B299)
- 05000366/LER-1979-136-03, /03L-0:on 791216,while Performing Function Test After Maint on Torus Vacuum Breaker 2T48-F323H,control Lights Failed to Give Open Indication at Local Panel or Control Room Panel.Cause Unknown.Breaker Will Be Replaced + (ML19257B300)
- 05000346/LER-1979-129, Forwards LER 79-129/03L-0 + (ML19257B301)
- ML19257B302 + (ML19257B302)
- ML19257B303 + (ML19257B303)
- ML19257B304 + (ML19257B304)
- 05000344/LER-1979-016-03, /03L-0:on 791208,routine Insp Found Leaking Pipe in Primary Coolant Charging Sys Core Component Pot Mini Flow Lines.Caused by Crack Developing at Gauge Marks Left on Pipe Surface from Improperly Installed 2-inch Welded Pipe + (ML19257B305)
- ML19257B306 + (ML19257B306)
- ML19257B307 + (ML19257B307)
- 05000346/LER-1979-129-03, /03L-0:on 791211,during Control Room Emergency Vent Sys 18-month Test ST 5076.02,charcoal Filter Bank in Unit 1-2 Failed to Meet Required Efficiency.Caused by Leak Between Filter Plate & Assembly.Plate Nuts Properly Torqued + (ML19257B308)
- ML19257B309 + (ML19257B309)
- ML19257B310 + (ML19257B310)
- ML19257B313 + (ML19257B313)
- ML19257B314 + (ML19257B314)