- 05000325/LER-1979-050, Forwards LER 79-050/03L-0 + (ML19209B235)
- ML19209B237 + (ML19209B237)
- ML19209B238 + (ML19209B238)
- ML19209B239 + (ML19209B239)
- ML19209B240 + (ML19209B240)
- ML19209B241 + (ML19209B241)
- ML19209B242 + (ML19209B242)
- 05000325/LER-1979-050-03, /03L-0:on 790904,during Normal Operation,Drywell Oxygen/Hydrogen Monitor CAC-1263 Was Observed Making Step Increase.Cause Unknown.Instrument Recalibr & Returned to Svc Satisfactorily + (ML19209B243)
- ML19209B244 + (ML19209B244)
- ML19209B245 + (ML19209B245)
- ML19209B246 + (ML19209B246)
- 05000325/LER-1979-064, Forwards LER 79-064/03L-0 + (ML19209B247)
- ML19209B249 + (ML19209B249)
- ML19209B250 + (ML19209B250)
- ML19209B253 + (ML19209B253)
- ML19209B254 + (ML19209B254)
- 05000325/LER-1979-064-03, /03L-0:on 790908,while Performing Control Rod Operability Check,Rod 02-35 Had No Position Indication at Notch 46 When Driven In.Cause Not Found.All Rods Will Be Monitored During Operation & Rod Moving Penetrant Tests + (ML19209B255)
- ML19209B256 + (ML19209B256)
- ML19209B258 + (ML19209B258)
- ML19209B259 + (ML19209B259)
- ML19209B261 + (ML19209B261)
- ML19209B262 + (ML19209B262)
- ML19209B264 + (ML19209B264)
- ML19209B265 + (ML19209B265)
- 05000333/LER-1979-060, Forwards LER 79-060/03L-0 + (ML19209B266)
- ML19209B267 + (ML19209B267)
- 05000333/LER-1979-060-03, /030-0:on 790904,reactivity Required to Demonstrate Shutdown Margin Was Found to Be Larger than Value Used During Demonstration at Beginning of Current Fuel Cycle + (ML19209B268)
- 05000409/LER-1979-015, Forwards LER 79-015/03L-0 + (ML19209B269)
- 05000333/LER-1979-063, Forwards LER 79-063/03L-0 + (ML19209B271)
- ML19209B272 + (ML19209B272)
- ML19209B273 + (ML19209B273)
- ML19209B275 + (ML19209B275)
- 05000333/LER-1979-063-03, /03L-0:on 790906,during Normal Startup,Control Rod Worth Minimizer Was Intentionally Bypassed.Caused by Revision in Control Rod Withdrawal Sequence + (ML19209B277)
- 05000409/LER-1979-015-03, /03L:on 790822,during Normal Operation,Auxiliary Operator Commenced Pumping Retention Tank 1B to River,Rather than Sampling 4,500 Gallon Waste Tank.Pumping Stopped & Tank Sampled.No Radiological Release Limits Exceeded + (ML19209B278)
- ML19209B279 + (ML19209B279)
- ML19209B280 + (ML19209B280)
- ML19209B282 + (ML19209B282)
- ML19209B283 + (ML19209B283)
- ML19209B284 + (ML19209B284)
- ML19209B286 + (ML19209B286)
- ML19209B287 + (ML19209B287)
- ML19209B288 + (ML19209B288)
- ML19209B289 + (ML19209B289)
- 05000333/LER-1979-062, Forwards LER 79-062/03L-0 + (ML19209B290)