- 05000324/LER-1979-071-03, /03L-0:on 790808,RHR Sys Pump 2D Vibrated at Level Higher than Allowable Limit During RHR Sys Operational Component Test.Caused by Spring Part Lodged in Vane of Impeller.Part Removed,Pump Inspected & Tested + (ML19208A096)
- 05000338/LER-1979-104, Forwards LER 79-104/01T-0 + (ML19208A097)
- ML19208A098 + (ML19208A098)
- 05000338/LER-1979-104-01, /01T-0:on 790823,feeder Breakers to Several Electrical Penetrations Found Not Set to Protect Penetration Integrity for Range of Faults.Caused by Design Problem + (ML19208A099)
- ML19208A100 + (ML19208A100)
- ML19208A101 + (ML19208A101)
- 05000368/LER-1979-068-03, /03L-0:on 790812,emergency Feedwater Flow Control Valve 2CV-1025-1 from Pump 2P7B to Steam Generator a Failed to Fully Close from Control Room Demand Signal.Caused by Nonalignment of Limit Stop Switch.Switch Realigned + (ML19208A102)
- 05000368/LER-1979-067-04, /04L-0:on 790808,auxiliary Bldg Radwaste Area Radiation Monitor 2RE-E542 Sample Pump Found W/Broken Coupling.Cause Not Stated.Plastic Coupling Replaced W/Metal Coupling.Appropriate Grab Samples Taken + (ML19208A103)
- 05000368/LER-1979-064-03, /03L-0:on 790807,trips in Plant Protection Sys D Placed in Bypass to Investigate Oscillations in delta-T Power Indication.Caused by Cold Leg Temp Indication Oscillation.All Related Signal Connections Tightened + (ML19208A104)
- 05000368/LER-1979-069-03, /03L-0:on 790814,diesel Generator 2 Could Not Be Stopped from Control Room Handswitch 2HS-2829-2 During Mode 2 Operation.Caused by Internal Spring on Handswitch Contact Being Out of Adjustment.Spring & Switch Contacts Adjust + (ML19208A105)
- 05000266/LER-1979-011, Forwards LER 79-011/01T-0 + (ML19208A106)
- ML19208A107 + (ML19208A107)
- 05000266/LER-1979-011-01, /01T-0:on 790804,while Proceeding to Cold Shutdown Condition,Containment Integrity Was Briefly Violated.Caused by Faulty Interlock Allowing Inside Containment Door to Open When Outside Door Was Already Open + (ML19208A108)
- ML19208A109 + (ML19208A109)
- 05000254/LER-1979-024, Forwards LER 79-024/03L-0 + (ML19208A110)
- ML19208A111 + (ML19208A111)
- 05000254/LER-1979-024-03, /03L-0:on 790724,pressure Suppression Chamber Reactor Bldg Vacuum Breaker Pressure Switch Was Found to Actuate Below Limiting Condition for Operation Level.Caused by Instrument Setpoint Drift.Switch Recalibr + (ML19208A112)
- ML19208A113 + (ML19208A113)
- ML19208A114 + (ML19208A114)
- ML19208A116 + (ML19208A116)
- ML19208A117 + (ML19208A117)
- ML19208A119 + (ML19208A119)
- ML19208A121 + (ML19208A121)
- ML19208A123 + (ML19208A123)
- ML19208A124 + (ML19208A124)
- ML19208A136 + (ML19208A136)
- ML19208A137 + (ML19208A137)
- ML19208A139 + (ML19208A139)
- ML19208A140 + (ML19208A140)
- ML19208A142 + (ML19208A142)
- ML19208A143 + (ML19208A143)
- ML19208A147 + (ML19208A147)
- ML19208A150 + (ML19208A150)
- ML19208A159 + (ML19208A159)
- ML19208A161 + (ML19208A161)
- ML19208A167 + (ML19208A167)
- ML19208A169 + (ML19208A169)
- ML19208A170 + (ML19208A170)
- ML19208A172 + (ML19208A172)
- ML19208A173 + (ML19208A173)
- ML19208A176 + (ML19208A176)
- ML19208A178 + (ML19208A178)
- ML19208A179 + (ML19208A179)
- ML19208A180 + (ML19208A180)
- ML19208A182 + (ML19208A182)
- ML19208A183 + (ML19208A183)
- ML19208A184 + (ML19208A184)
- ML19208A185 + (ML19208A185)
- ML19208A186 + (ML19208A186)
- ML19208A189 + (ML19208A189)
- ML19208A190 + (ML19208A190)