Forwards LERs 79-068/03L-0,79-067/04L-0,79-064/03L-0 & 79-069/03L-0
Date released: 08/10/2019 Download: ML19208A101


LER 79-069/03L-0:on 790814,diesel Generator 2 Could Not Be Stopped from Control Room Handswitch 2HS-2829-2 During Mode 2 Operation.Caused by Internal Spring on Handswitch Contact Being Out of Adjustment.Spring & Switch Contacts Adjusted
ML19208A105
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 09/05/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19208A105 (1)
LER 79-064/03L-0:on 790807,trips in Plant Protection Sys D Placed in Bypass to Investigate Oscillations in delta-T Power Indication.Caused by Cold Leg Temp Indication Oscillation.All Related Signal Connections Tightened
ML19208A104
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 09/05/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19208A104 (1)
LER 79-067/04L-0:on 790808,auxiliary Bldg Radwaste Area Radiation Monitor 2RE-E542 Sample Pump Found W/Broken Coupling.Cause Not Stated.Plastic Coupling Replaced W/Metal Coupling.Appropriate Grab Samples Taken
ML19208A103
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 09/05/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19208A103 (1)
LER 79-068/03L-0:on 790812,emergency Feedwater Flow Control Valve 2CV-1025-1 from Pump 2P7B to Steam Generator a Failed to Fully Close from Control Room Demand Signal.Caused by Nonalignment of Limit Stop Switch.Switch Realigned
ML19208A102
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 09/05/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19208A102 (1)
Forwards LERs 79-068/03L-0,79-067/04L-0,79-064/03L-0 & 79-069/03L-0
ML19208A100
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 09/05/1979
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19208A100 (1)