ML19208A140

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-19, Packaging of Low-Level Radioactive Waste for Transportation & Burial. Action Required
ML19208A140
Person / Time
Issue date: 08/10/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
BOMHOFF & ASSOCIATES, INC.
References
NUDOCS 7909130093
Download: ML19208A140 (1)


Text

.[gnMco, 'o UNITED ST ATES

/l\\

9f*' 7, NUCLEAR REGULATORY COMMISSION yit

,g/

REGION V

i 4DJjljys /, g, 1990 rJ. Calli'ORM A BOULEVAf
D o

j' SUIT E 202, WALNUT CitL E K PL AZA g

N :

WALfJU T CIIL E K, C ALIFORf41 A 94596 August 10, 1979 buMMUFF ANU AbduLIATES INC.

LUNdiHUCT;UN INSFECTIUN 1040 HEST INTkkN5TIONAL AIRPUR AK 99502 ANLbuRAbt Gentlemen:

nclosed is IE Bulletin No. 79-19 which requires action by you with r

regard to your URC license.

Should you have questions regarding this Bulletin or the actions re-quired of you, please contact this office.

Sincerely,

[$

abnu -

m g

,g.- R. H. Engel ken dg Director o

Enclosure:

a

((U _11_ I.) "J _.a IE Bulletin No. 79-19

?33138 7909130 @ ]

Accession No:

7908070515 SSINS t!o:

6820 9

UNITED STATES NUCLEAR REGULATORY C0". MISSION OFFICE OF IliSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 10, 1979 IE Bulletin No. 79-19 PACKAGING 0F LOW-LEVEL RADI0 ACTIVE WASTE FOR TRANSPORT AND BURIAL Description of Circumstances:

Low-level radioactive waste is that waste which can be transferred and shipped to one of three waste burial facilities which are located in and licensed by the Agreenent States of Nevada, South Carolina, and Washington. On July 10, 1979, the Governors of the three states notified NRC Chairman Hendrie of the serious and repeated disrecard for rules covernina the shipments of low-level radioactive wastes to these t S1 facilities.

Examples of violations of Agreement State, DOT and NRC rules follow:

Improperly packaged uranium fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire and destruction of a truck at the Beatty, llevada burial facility on May 14, 1979.

On July 2,1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactive material.

The material was described on the bill of lading as beina a solid inoraanic salt (evaporator concentrates solidified with urea fonnaldehyde) from a reactor facility.

The Governor of the State of flevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.

On July 30, the first shipment into the reopened Beatty facility contained free liquid in " solid" material. The radioactive contents were sand filters used at an insitu leaching process at a uranium mill.

Forty-three shipments with sixty-three deficiencies were observed during the package inspection program between April 10 and July 5,1979, by the Agreement State of South Carolina, at the Barnwell, S.C. burial facility. The shipments were fron reactor, medical, industrial and military facilities.

On June 28, 1979, the Federal Highway Administration issued a flotice of Violation to a reactor facility proposing a $10,000 fine for truck contamina-tion resulting from inproper closures on 55-gallon drums of LSA material and for improper loading of the druns on the vehicle.

These are a few examples of shipments of radioactive material to burial facilities which did not fully meet flRC, D0T and Aqreement 3 tate requirements which were developed to protect the health and safety of the public. The Governors of the three States with licensed burial facilities have indicated that if the situation is not rectified, they may have to initiate actions which would deny use of the three burial sites by violators.

733139

u

[ O(. J(9 D

2 Jj~jl August 10, 1979 IE Bulletin No. 79-19 0' 9~I Page 2 of 3 U

Sources of Information:

The DOT regulatory requirements can be found in 49 CFR Parts 170-179. The NRC regulatory requirements can be found in 10 CFR Parts 19 to 71. The NRC regu-latory requirements for Agreenent State licensees in non-agreement states are in 10 CFR Part 150. Copies of the regulations may be purchased from the Superintendent of Documents, U. S. Government Printing Office, Washinoton, D.C. 20402.

Information about licensing requirements for liRC packages can be obtained from the NRC Trarscortaticn Panch (301 a27 a122).

Information about 00T packaaing and transport requirements can be obtained by calling the DDT Office of Hazardous Materials (202-426-2311).

Action To Be Taken By Licensees:

To assure the safe transfer, packaging, and transport of low-level radioactive waste, each licensee is expected to:

1.

Maintain a current set of D0T and fiRC regulations concerning the transfer, packaging and transport of low-level radioactive waste naterial.

2.

Maintain a current set of requirerents (license) placed on the waste burial firm by the Agreenent State of Nevada, South Carolina, or Washington before packaging low-level radioactive waste material for transfer and shipment to the Agreement State licensee.

If a waste collection contractor is used, obtain the appropriate requirements from the contractor.

3.

Designate, in writing, people in your organization who are responsible for the safe transfer, packaging and transport of low-level radioactive material.

4.

Provide management-approved, detailed instructions and operating procedures to all personnel involved in the transfer, packaging and transport of low-level radioactive naterial.

Special attention should be given to controls on the chemical and physical form of the low-level radioactive material and on the containment integrity of the packaging.

5.

Provide training and periodic retraining in the DOT and f!RC regulatory requirements, the waste burial license requirements, and in your instruc-tions and operating procedures for all personnel involved in the transfer, packaging and transport of radioactive material.

Maintain a record of training dates, attendees, and subject naterial for future inspections by flRC personnel.

6.

Provide training and periodic retraining to those employees who operate the processes which generate waste to assure that the volume of low-level radioactive waste is minimized and that such waste is processed into acceptable chemical and physical form for transfer and shipment to a low-level radioative waste burial facility.

73d140

IE Bulletin ?!o. 79-19 August 10, 1979 Page 3 of 3 7.

Establish and implement a management-controlled audit function of all transfer, packagina and transport activities to provide assurance that personnel, instructions and procedures, and process and transport equip-ment are functioning to ensure safety and compliance with regulatory requirements.

8.

Perform, within 60 days of the date of this bulletin, a nanagement-controlled audit of your activities associated with the transfer, packaging and trans-port of low-level radioactive waste.

Maintain a record of all audits for future insnections by NRC or DOT insnectors.

(flote: If you have an estab-lished audit function and have performed such an audit of all activities in Items 1-6 within the past six months, this audit requirement is satisfied.)

9.

Report, in writing within 45 days, your plan of action and schedule with regard to the above items.

In addition, provide responses to the three questions below.

Reports should be submitted to the Director of the appropriate f!RC Regional Office and a copy should be forwarded to the f!RC Office of Inspection and Enforcement, Division of Fuel Facility and Materials Safety Inspection, Washington, D.C.

20555.

Provide answers for 1978 and for the first six months of 1979 to the following questions:

1 How many low-level radioactive waste shipments did you nake? 'Jhat was the volume of low-level radioactive waste shipped?

(Power reactor licensees who report this information in accordance with Technical Specifications do not need to respond to this question.)

2.

What was the quantity (curies) of low-level radioactive waste shipped? What were the major isotopes in the low-level radioactive waste?

(Power reactor licensees who report this information in ccordance with Technical Specifications do not need to respond to this question.)

3.

Did you generate liquid low-level radioactive waste?

If the answer is 'yes,' what process was used to solidify the liquid waste?

Licensees who do not generate low-level radioactive waste should so indicate in their responses and do not need to take other actions specified in the above items.

Approved by GAO, B180225 (R0072); clearance expires 7-31-80.

Approval was given under a blanket clearance snecifically for identified generic problens.

733141