- 05000280/LER-1988-021, :on 880728,PORV Cycled Open & Then Closed. Caused by Overly Conservative Setpoint.Setpoint Changed + (ML18153B496)
- IR 05000280/1988011 + (ML18153B498)
- ML18153B499 + (ML18153B499)
- 05000281/LER-1988-016-02, :on 880731,discovered That Individual Rod Position Indicators (Irpis) Differed from Group Step Demand Counter by Greater than 12 Steps.Caused by Drift in Irpi Indication.Irpis Adjusted + (ML18153B500)
- ML18153B501 + (ML18153B501)
- IR 05000280/1988003 + (ML18153B502)
- ML18153B503 + (ML18153B503)
- ML18153B505 + (ML18153B505)
- ML18153B506 + (ML18153B506)
- ML18153B507 + (ML18153B507)
- 05000281/LER-1988-019-03, :on 880901,steam Generator a Inside Containment Steam Valve Closed for No Apparent Reason Due to Actuation of High Flow Trip Solenoid.Solenoid Reset,Blowdown Flow Established & Trip Valve & Solenoid Verified + (ML18153B508)
- 05000280/LER-1988-035, :on 880914,specific Activity Sample of Reactor Coolant Showed Dose Equivalent I-131 Level of 1.04 Microcuries/Cc,Exceeding Tech Spec Limits.Caused by Iodine Spike Due to Fuel Element Defects + (ML18153B509)
- ML18153B510 + (ML18153B510)
- ML18153B512 + (ML18153B512)
- ML18153B513 + (ML18153B513)
- PNO-II-88-061, during Wk of 880919,util Identified Some Pipe Wall Thinning in Main Feedwater Piping.On or About 880926, Util Identified Main Feedwater Piping Below Min Code Requirements for Acceptability.Nrc Being Kept Informed + (ML18153B514)
- ML18153B515 + (ML18153B515)
- ML18153B517 + (ML18153B517)
- ML18153B519 + (ML18153B519)
- ML18153B520 + (ML18153B520)
- ML18153B521 + (ML18153B521)
- ML18153B523 + (ML18153B523)
- ML18153B525 + (ML18153B525)
- IR 05000280/1988030 + (ML18153B526)
- IR 05000280/1988013 + (ML18153B527)
- IR 05000280/1988034 + (ML18153B528)
- ML18153B529 + (ML18153B529)
- ML18153B530 + (ML18153B530)
- ML18153B531 + (ML18153B531)
- 05000281/LER-1988-021-01, :on 880908,required Test Frequency for B Low Head Safety Injection Pump Exceeded.Caused by Inability of Operator to Obtain Required Vibration Test W/Test Equipment Used.Formal Training of Equipment Administered + (ML18153B532)
- ML18153B533 + (ML18153B533)
- 05000281/LER-1988-020-01, :on 880909,individual Rod Position Indicators for Four Control Rods of Control Bank D Differed from Demand Counter by More than 12 Steps.Caused by Indicator Indication Drift.Indicators Adjusted + (ML18153B534)
- 05000280/LER-1988-017, :on 880606,foreign Matl Found in Temporary Discharge Cone Strainer & Deficiencies Found in Sump Screens.Caused by Inadequate Insp Program During Const Activities.Foreign Objects Removed + (ML18153B536)
- ML18153B537 + (ML18153B537)
- ML18153B538 + (ML18153B538)
- ML18153B539 + (ML18153B539)
- ML18153B540 + (ML18153B540)
- 05000281/LER-1988-024-01, :on 881007,damage to Internal Components & Other Discrepancies During Disassembly of Inside Recirculation Spray Pumps a & B Noted.Cause Undetermined. Foreign Matl Removed.Repair of Pumps Initiated + (ML18153B542)
- 05000281/LER-1988-023-02, :on 881006,three Containment Trip Valves Found Closed & Radiation Monitor Sample Pump & Particulate Monitor Discovered Stopped Due to Trip Valve Interlock.Caused by Personnel Error.Trip Valves Opened + (ML18153B543)
- 05000280/LER-1988-040, :on 881012,potential Accumulation of Gases in Suction Piping of High Head Safety Injection Sys Pumps Determined.Caused by Inadequate Design of Sys.Engineering Work in Progress to Design & Install Vents + (ML18153B544)
- 05000280/LER-1988-039, :on 881011,control/relay Room Chiller Tripped. Caused by Small Refrigerant Leak & Insufficient Svc Water Flow.Svc Water Flow Increased Through Chiller B by Throttling Open Chiller Svc Water Outlet Valve + (ML18153B545)
- ML18153B546 + (ML18153B546)
- ML18153B547 + (ML18153B547)
- 05000280/LER-1988-031, :on 880912,determined That Adequate Supply of Svc Water May Not Be Available to Provide Sufficient Flow to Recirculation Spray HXs in Event of LOCA & Loss of Offsite Power.Caused by Design Deficiency + (ML18153B548)
- IR 05000280/1988026 + (ML18153B549)
- ML18153B551 + (ML18153B551)
- 05000280/LER-1988-042, :on 881016,w/Unit 1 in Refueling Shutdown & Unit 2 in Cold Shutdown,Process Vent High Range Effluent Monitors Declared Inoperable.Caused by Failed Flow Control Circuit Board.Preplanned Operation Verified + (ML18153B553)