- ML18139B334 + (ML18139B334)
- 05000280/LER-1981-011, Forwards LER 81-011/03L-0 + (ML18139B345)
- ML18139B346 + (ML18139B346)
- 05000280/LER-1981-011-03, /03L-0:on 810426 & 27,process Vent Radiation Monitors Flooded Due to Introduction of Water Into Process Vent Sys.Caused by Failure of Primary Drain Tank Level Control Sys.Monitors Drained & Vacuum Pump Replaced + (ML18139B347)
- ML18139B348 + (ML18139B348)
- ML18139B350 + (ML18139B350)
- ML18139B351 + (ML18139B351)
- ML18139B352 + (ML18139B352)
- ML18139B353 + (ML18139B353)
- ML18139B354 + (ML18139B354)
- ML18139B355 + (ML18139B355)
- IR 05000280/1981012 + (ML18139B357)
- ML18139B358 + (ML18139B358)
- ML18139B359 + (ML18139B359)
- ML18139B360 + (ML18139B360)
- 05000281/LER-1981-027, Forwards LER 81-027/03L-0 + (ML18139B361)
- ML18139B362 + (ML18139B362)
- 05000281/LER-1981-027-03, /03L-0:on 810501,TV-MS-201C Control Circuit Would Not Respond to Train B Actuation Signal.Caused by Shorting of Train B Coil Due to Moisture.Coil Replaced + (ML18139B363)
- ML18139B364 + (ML18139B364)
- ML18139B365 + (ML18139B365)
- ML18139B366 + (ML18139B366)
- ML18139B367 + (ML18139B367)
- 05000281/LER-1981-028-03, /03L-0:on 810502,emergency Diesel Generator Output Breaker Closed Inadvertently,Motorizing Generator 3.Caused by Inadequate Procedure Not Positively Controlling Generator Position.Generator Started & Loaded + (ML18139B368)
- 05000281/LER-1981-029-03, /03L-0:on 810502,leakage Monitoring Valve 2-CV-12 Found Open & Downstream Pipe Cap Missing Following Return to Power on 810428.Caused by Inadequate Procedure.Valve Closed & Pipe Cap Replaced + (ML18139B369)
- 05000281/LER-1981-030-03, /03L-0:on 810504,emergency Diesel Generator Output Breaker Opened on Overspeed.Caused by Misaligned Overspeed Trip Limit Switch.Limit Switch Adjusted & Generator Tested Satisfactorily + (ML18139B370)
- ML18139B371 + (ML18139B371)
- ML18139B373 + (ML18139B373)
- ML18139B374 + (ML18139B374)
- ML18139B376 + (ML18139B376)
- ML18139B377 + (ML18139B377)
- ML18139B378 + (ML18139B378)
- IR 05000280/1981002 + (ML18139B379)
- ML18139B380 + (ML18139B380)
- ML18139B383 + (ML18139B383)
- ML18139B384 + (ML18139B384)
- 05000280/LER-1981-009-01, /01T-0:on 810522,Westinghouse Identified Potential Sys Interaction Involving Vol Control Tank Level Control Sys & Charging Pumps.Caused by Design Criteria Misinterpretation.Procedure Mods Will Be Made + (ML18139B385)
- 05000280/LER-1981-012-03, /03L-0:on 810506,seismic Instrumentation Found Not Calibr According to Tech Specs.Caused by Defective Procedures.Periodic Test Had Been Mislabeled as Calibr Procedure.Instrumentation Calibr Using Approved Procedure + (ML18139B386)
- 05000280/LER-1981-031-03, /03L-0:on 810508,amp Reading for Heat Tracing Panel 11,circuit 1B,found Below Acceptance Criteria.Caused by Mechanical Damage to Tape.Heat Tracing Replaced & Tested. Design Change Initiated + (ML18139B387)
- 05000280/LER-1981-033-03, /03L-0:on 810518,amp Reading for Heat Tracing Panel 8,circuit 6A,found Below Acceptance Criteria.Caused by Excessive Heat.Tracing Replaced & Tested.Design Change Initiated + (ML18139B389)
- ML18139B390 + (ML18139B390)
- IR 05000280/1981010 + (ML18139B392)
- ML18139B394 + (ML18139B394)
- ML18139B395 + (ML18139B395)
- ML18139B397 + (ML18139B397)
- IR 015000039/1981003 + (ML18139B398)
- ML18139B399 + (ML18139B399)
- ML18139B400 + (ML18139B400)
- ML18139B401 + (ML18139B401)
- ML18139B402 + (ML18139B402)
- ML18139B403 + (ML18139B403)
- ML18139B404 + (ML18139B404)