- IR 05000311/1996080 + (ML18102A873)
- ML18102A874 + (ML18102A874)
- ML18102A875 + (ML18102A875)
- ML18102A876 + (ML18102A876)
- ML18102A877 + (ML18102A877)
- ML18102A878 + (ML18102A878)
- ML18102A880 + (ML18102A880)
- LR-N970079, Responds to NRC Re Violations Noted in Insp Repts 50-272/96-18,50-311/96-18 & 50-354/96-10.Corrective Actions: Individual in Protected Area Without photobadge-keycard Was Counseled + (ML18102A882)
- ML18102A885 + (ML18102A885)
- LR-N970133, Notifies NRC of Changes to Plant ERDS Data Point Library, Which Affect Alarm/Trip Setpoints for ERDS Data Points U2NM0041FS,U2LT0501S,U2LT0502S,U2LT0503S,U2LT0504S,U2PT0405S & U2LT0938S + (ML18102A888)
- ML18102A889 + (ML18102A889)
- 05000272/LER-1997-003-01, :on 970131,new Alignment Assumes Single Failure of 125 Volt Dc Channel Resulted in Two SWS Pumps in Runout Condition Which Caused Insufficient SWS Flow Rates.Modified SW223 Valves for Five Unit 2 Cfcus + (ML18102A893)
- ML18102A895 + (ML18102A895)
- ML18102A896 + (ML18102A896)
- ML18102A897 + (ML18102A897)
- ML18102A898 + (ML18102A898)
- ML18102A899 + (ML18102A899)
- ML18102A901 + (ML18102A901)
- ML18102A902 + (ML18102A902)
- ML18102A904 + (ML18102A904)
- IR 05000311/1996021 + (ML18102A905)
- 05000272/LER-1996-036, :on 961106,28 Volt Dc Battery Capacity Was Exceeded.Caused by Inattention to Detail.Replaced Lamps Installed in CR Console push-button Stations + (ML18102A906)
- 05000272/LER-1997-002-01, :on 970210,chilled Water Sys Single Failure Vulnerabilities Identified.Caused by Design Deficiency. License Change Request S97-05 Submitted + (ML18102A907)
- 05000311/LER-1996-020, Provides Notification of Change in Commitment Implementation Schedule Re Potential for Thermal Overpressurization of Containment Fan Coil Unit Piping Per LER 96-020 + (ML18102A908)
- LR-N970177, Provides 180-day Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Movs + (ML18102A910)
- ML18102A911 + (ML18102A911)
- ML18102A914 + (ML18102A914)
- ML18102A915 + (ML18102A915)
- ML18102A918 + (ML18102A918)
- ML18102A920 + (ML18102A920)
- ML18102A923 + (ML18102A923)
- LR-N970181, Submits Suppl to Request for Change to TSs Section 6.0, Administrative Controls Re Salem & Hope Creek Generating Station Units 1 & 2 + (ML18102A925)
- 05000311/LER-1997-002-02, :on 970213,discovered non-seismically Qualified Pressure Switches in Auxiliary Bldg Ventilation.Caused by Pressure Switches Being Replaced w/non-qualified Pressure switches.Re-installed Qualified Switches + (ML18102A926)
- ML18102A927 + (ML18102A927)
- ML18102A928 + (ML18102A928)
- ML18102A929 + (ML18102A929)
- ML18102A930 + (ML18102A930)
- ML18102A931 + (ML18102A931)
- LR-N970124, Provides Addl Technical Info Discussed in Telcon to Support Relief from Commitment to Post Weld Heat Treat (PWHT) Weld Repairs Made to SA-351 Grade CD4MCu Matl for Svc Water Pumps at Salem & Hope Creek + (ML18102A932)
- ML18102A933 + (ML18102A933)
- IR 05000272/1996018 + (ML18102A936)
- 05000272/LER-1997-004-01, :on 970221,inadequate Surveillance Testing of Molded Case Circuit Breakers Were Identified.Caused by Instantaneous Function Not Accurately Specified in Procedure.Tssip Has Been Initiated + (ML18102A938)
- ML18102A939 + (ML18102A939)
- ML18102A941 + (ML18102A941)
- ML18102A942 + (ML18102A942)
- ML18102A943 + (ML18102A943)
- ML18102A946 + (ML18102A946)
- ML18102A947 + (ML18102A947)
- ML18102A951 + (ML18102A951)
- ML18102A953 + (ML18102A953)
- 05000272/LER-1997-006, :on 970312,determined Relays That Are Part of Logic for Opening PORVs Were Not Tested.Caused by Lack of Adequate Control for Maint of TS Surveillance Procedures. Initiated New Procedures & Revised Procedures + (ML18102A958)