- 05000311/LER-1988-005-02, :on 880404,discovered That Hourly Roving Fire Watch Was 23 Minutes Late for 122 Ft Auxiliary Bldg Area. Caused by Personnel Error.Performance of Hourly Fire Watch Surveillances Stressed + (ML18093A817)
- ML18093A818 + (ML18093A818)
- ML18093A819 + (ML18093A819)
- ML18093A820 + (ML18093A820)
- IR 05000272/1988010 + (ML18093A822)
- IR 05000272/1987037 + (ML18093A823)
- ML18093A824 + (ML18093A824)
- ML18093A825 + (ML18093A825)
- ML18093A826 + (ML18093A826)
- ML18093A827 + (ML18093A827)
- ML18093A828 + (ML18093A828)
- ML18093A829 + (ML18093A829)
- ML18093A830 + (ML18093A830)
- 05000311/LER-1988-006-02, :on 880421,reactor Trip Occurred.Caused by Maint Technician Not Using Proper Procedure When Repairing Leak on Low Pressure Side of Reactor Coolant Loop 23 Flow Channel II Transmitter.Event Reviewed + (ML18093A831)
- ML18093A833 + (ML18093A833)
- ML18093A834 + (ML18093A834)
- ML18093A835 + (ML18093A835)
- ML18093A836 + (ML18093A836)
- ML18093A837 + (ML18093A837)
- ML18093A839 + (ML18093A839)
- 05000272/LER-1988-001, :on 880211,improper Anchoring of Three Diesel Generator Day Tanks to Supporting Steel Beam Foundation Identified.Caused by Inadequate Design & Design Review. Tanks Weld Anchored to Steel Beam Foundation + (ML18093A840)
- 05000272/LER-1988-018, :on 871209,personnel Determined That Lead/Lag & Derivative Amplifiers in Process & Protection Control Sys Incorrectly Calibr.Caused by Procedural Inadequacy. Procedures Revised + (ML18093A841)
- 05000311/LER-1988-008-02, :on 880426,discovered That Valve 2FP147 Not Surveilled.Caused by Personnel Error.Procedure Revised to Address Requirement to Surveill the 2FP147 Valve & 2FP148 Check Valve at Same Time + (ML18093A842)
- ML18093A845 + (ML18093A845)
- IR 05000272/1988011 + (ML18093A850)
- ML18093A855 + (ML18093A855)
- 05000311/LER-1988-007-02, :on 880422,reactor Trip Occurred Due to Turbine Trip as Result of Steam Generator hi-hi Level.Caused by electro-hydraulic Control (EHC) Equipment Problems.Ehc Rate Amplifier Card Replaced & Successfully Tested + (ML18093A857)
- ML18093A858 + (ML18093A858)
- ML18093A859 + (ML18093A859)
- ML18093A860 + (ML18093A860)
- ML18093A861 + (ML18093A861)
- 05000272/LER-1988-010-01, :on 880519,discovered That Diesel Generator Area Cardox Fire Suppression Sys PE Relay May Not Be Class 1E Seismically Qualified.Caused by Inadequate Design. Procedure Mods Made Re Resetting Relay + (ML18093A863)
- ML18093A864 + (ML18093A864)
- 05000311/LER-1988-009-02, :on 880513,reactor Trip Occurred.Caused by Control Rod 1D3 Drop Resulting in Negative Rate Trip.Testing for Probable Causes of Control Rod Drop Completed + (ML18093A868)
- ML18093A869 + (ML18093A869)
- ML18093A870 + (ML18093A870)
- ML18093A874 + (ML18093A874)
- 05000311/LER-1988-010-02, :on 880509,identified That for 37 Electrical Circuits Penetrating Containment,Backup Overcurrent Protection Device Would Not Operate.Caused by Inadequate Design Review.Detailed Calculation Prepared + (ML18093A875)
- ML18093A876 + (ML18093A876)
- ML18093A877 + (ML18093A877)
- ML18093A878 + (ML18093A878)
- ML18093A879 + (ML18093A879)
- ML18093A881 + (ML18093A881)
- ML18093A883 + (ML18093A883)
- ML18093A884 + (ML18093A884)
- ML18093A885 + (ML18093A885)
- ML18093A890 + (ML18093A890)
- ML18093A891 + (ML18093A891)
- ML18093A893 + (ML18093A893)
- ML18093A894 + (ML18093A894)
- ML18093A895 + (ML18093A895)