- ML17331A605 + (ML17331A605)
- 05000316/LER-1981-002-03, /03L-0:on 810103,east Motor Auxiliary Feed Pump Inoperable.Caused by Repair of Emergency Leakoff Line Check Valve FW-153.Check Valve Disc Replaced,Seat Lapped & Spool Piece Installed in Place of Strainer + (ML17331A607)
- ML17331A609 + (ML17331A609)
- ML17331A611 + (ML17331A611)
- ML17331A613 + (ML17331A613)
- ML17331A620 + (ML17331A620)
- ML17331A621 + (ML17331A621)
- ML17331A622 + (ML17331A622)
- RS-17-163, Withdrawal of Relief Request RV-2 Associated with the Fourth Inservice Testing Interval + (ML17331A623)
- ML17331A627 + (ML17331A627)
- ML17331A638 + (ML17331A638)
- ML17331A639 + (ML17331A639)
- 05000315/LER-1981-001-03, /03L-0:on 810112,boron Concentration in Boron Injection Tank & North Boric Acid Storage Tank Found Diluted Below Tech Spec Level.Cause Unknown.Boron Concentration Increased + (ML17331A640)
- ML17331A643 + (ML17331A643)
- ML17331A644 + (ML17331A644)
- ML17331A646 + (ML17331A646)
- IR 05000315/1980019 + (ML17331A648)
- ML17331A650 + (ML17331A650)
- IR 05000315/1980022 + (ML17331A652)
- 05000316/LER-1980-035-03, Rod Position Indication for Rod N-9 Did Not Respond Properly While Pulling Shutdown Control Rods in Preparation for Going Critical.Connector on Top of Rod Position Detector Assembly Appeared Stepped on + (ML17331A653)
- ML17331A654 + (ML17331A654)
- ML17331A657 + (ML17331A657)
- ML17331A658 + (ML17331A658)
- ML17331A659 + (ML17331A659)
- ML17331A660 + (ML17331A660)
- ML17331A661 + (ML17331A661)
- ML17331A664 + (ML17331A664)
- ML17331A665 + (ML17331A665)
- 05000316/LER-1981-001-04, No Apparent Flow Observed Through Radiation Monitor R-19 from Steam Generator 21. Caused by Bad Diaphragm in roto-meter Flow Regulator.Flow Meters to Radiation Monitor to Be Modified + (ML17331A666)
- ML17331A667 + (ML17331A667)
- 05000315/LER-1980-039, Forwards LER 80-039/03L-0,updated LER 80-034/03X-2 & + (ML17331A668)
- ML17331A670 + (ML17331A670)
- 05000316/LER-1980-034-03, Containment Isolation Valve NCR-252 Found Not Fully Seated W/Shut Indication in Control Room During Mode 5.Cause Undetermined.Valve Stroke Adjusted + (ML17331A671)
- 05000316/LER-1980-039-03, /03L-0:on 800728,low Pressure Alarm Failed to Clear W/Increased Nitrogen Pressure.Cause Not Stated.Refs Encl Response to IE Insp Repts 50-315/80-15 & 50-316/80-14 + (ML17331A672)
- ML17331A673 + (ML17331A673)
- ML17331A675 + (ML17331A675)
- ML17331A676 + (ML17331A676)
- ML17331A677 + (ML17331A677)
- IR 05000315/1980024 + (ML17331A680)
- ML17331A681 + (ML17331A681)
- ML17331A682 + (ML17331A682)
- ML17331A684 + (ML17331A684)
- ML17331A685 + (ML17331A685)
- ML17331A686 + (ML17331A686)
- ML17331A687 + (ML17331A687)
- ML17331A688 + (ML17331A688)
- 05000316/LER-1981-005-01, /01T-0:on 810331,spray Additive Tank Level Found Below Tech Spec Limit During Removal of Magnetrol for 18 Month Surveillance.Caused by Absence of Alarm Due to Contacts Wired Backwards.Tank Refilled + (ML17331A689)
- ML17331A691 + (ML17331A691)
- ML17331A692 + (ML17331A692)
- 05000316/LER-1981-006-03, /03L-0:on 810316,during Automatic Load Sequence Surveillance Test,Safety Injection Sys Relay Timers Exceeded Tolerance Allowed by Tech Specs.Caused by Instrument Drift. Component Cooling Water Pump 2E Timer Replaced + (ML17331A699)
- 05000316/LER-1981-007-03, /03L-0:on 810315 During Operation of 2CD Emergency Diesel in Preparation for Surveillance,Hot Starting Air Line Observed.Caused by Valve Damage & Exhaust Expansion Joint Inner Liner Failure.Intake & Exhaust Valves Replaced + (ML17331A700)