- 05000316/LER-1980-022, Forwards LER 80-022/03L-0 & Updated LER 79-041/03L-1 + (ML17331A176)
- ML17331A177 + (ML17331A177)
- ML17331A178 + (ML17331A178)
- 05000316/LER-1980-022-03, /03L-0:on 800503,radiation Monitor R-11 Alarmed During Normal Operation.Sample Pump for R-11 & R-12 Would Not Remain Running.Caused by Wear of Pump.Pump Replaced & Air Sampler Tested.Entire Sys Will Be Replaced + (ML17331A179)
- 05000316/LER-1979-041-03, Hydrogen Recombiner 1 Failed to Increase Temp to 1,200 F within 5-h.Caused by Incorrect Electrical Connection of One Heater Element.Wiring Corrected & Controller Gain & Bias Adjusted + (ML17331A180)
- ML17331A181 + (ML17331A181)
- ML17331A182 + (ML17331A182)
- ML17331A183 + (ML17331A183)
- ML17331A185 + (ML17331A185)
- ML17331A186 + (ML17331A186)
- ML17331A187 + (ML17331A187)
- ML17331A188 + (ML17331A188)
- 05000316/LER-1980-023-03, /03L-0:on 800516,during Normal Operation,Low Flow Alarm for Containment Apd R-11 & R-12 Was Received.Sample Pump Would Not Restart & R-11 & R-12 Were Declared Inoperable.Caused by Inaccurate Flow Meter.Meter Replaced + (ML17331A189)
- ML17331A190 + (ML17331A190)
- ML17331A191 + (ML17331A191)
- ML17331A192 + (ML17331A192)
- ML17331A193 + (ML17331A193)
- ML17331A194 + (ML17331A194)
- ML17331A195 + (ML17331A195)
- ML17331A197 + (ML17331A197)
- 05000316/LER-1980-025, Forwards LER 80-025/03L-0 + (ML17331A198)
- ML17331A199 + (ML17331A199)
- 05000316/LER-1980-025-03, /03L-0:on 800603,during Normal Operations, Engineered Safety Feature Vent Fan HV-AES-1 Circuit Breaker Tripped Rendering Ventilation Sys Inoperable.Caused by Failure of Wiring Insulation in Connection Boxes + (ML17331A200)
- ML17331A201 + (ML17331A201)
- ML17331A202 + (ML17331A202)
- ML17331A203 + (ML17331A203)
- ML17331A204 + (ML17331A204)
- 05000315/LER-1980-012-03, /03L-0:on 800609,two Check valves,R-156 & R-157, Discovered Utilized as Containment Isolation Valves.Valves Were Not Included in Type C Leak Test Prior to Nov 1978. Type C Leak Test Performed & Check Valves Added + (ML17331A205)
- 05000315/LER-1980-013-03, /03L-0:on 800616,transmitter for Steam Generator Level Loop 4 (Blp 142) Found to Be Out of Spec Low.Cause Attributed to Instrument Drift.Transmitter,Barton Model 764 Recalibr & Returned to Svc + (ML17331A206)
- 05000316/LER-1980-026, Forwards LER 80-026/03L-0 + (ML17331A207)
- ML17331A208 + (ML17331A208)
- 05000316/LER-1980-026-03, /03L-0:on 800609,check Valves R-156 & R-157, Utilized as Containment Isolation Valves,Found Omitted from Type C Leak Test.Valve R-156 Installed Backwards.Caused by Omission in Procedure.Valve R-156 Reinstalled & Tested + (ML17331A209)
- 05000315/LER-1980-014-03, /03L-0:on 800612,during Divider Barrier Seal Insp, Several Areas of Seal Found Cracked & Split.Cause of Seal Failure Unknown.Design Change Request Submitted to Investigate Alternate Matls + (ML17331A212)