- 05000529/LER-1987-015, :on 870816,control Room Essential Filtration Actuation Initiated on ESFAS Channels a & B.Caused by Voltage Spike on RU-30.Monitor Reset,Train B Returned to Svc & Procedural Change Initiated + (ML17303A706)
- 05000528/LER-1987-026, :on 871027,automatic Actuation of Balance of Plant ESF Occurred Due to Inadvertent Containment Purge Isolated Actuation Signal.Caused by Personnel Error. Responsible Individual Will Be Reinstructed + (ML17303A707)
- 05000530/LER-1987-005-02, :on 871030,while Unit in Mode 3,main Steam Isolation Sys Automatically Actuated.Caused by Faulty Logic Card for MSIV-170.Faulty Logic Card Replaced + (ML17303A708)
- ML17303A709 + (ML17303A709)
- ML17303A710 + (ML17303A710)
- IR 05000528/1987031 + (ML17303A712)
- ML17303A714 + (ML17303A714)
- ML17303A715 + (ML17303A715)
- ML17303A720 + (ML17303A720)
- ML17303A721 + (ML17303A721)
- ML17303A722 + (ML17303A722)
- ML17303A726 + (ML17303A726)
- ML17303A727 + (ML17303A727)
- ML17303A728 + (ML17303A728)
- ML17303A729 + (ML17303A729)
- 05000528/LER-1987-016, :on 870609,both Trains of ESF Pump Room Air Exhaust Cleanup Sys Inoperable.Caused by Personnel Error. Operations Dept Experience Rept & Night Orders Developed & Issued & Warning Tags Placed on Equipment + (ML17303A730)
- ML17303A731 + (ML17303A731)
- ML17303A732 + (ML17303A732)
- ML17303A733 + (ML17303A733)
- ML17303A734 + (ML17303A734)
- ML17303A738 + (ML17303A738)
- IR 05000247/2017008 + (ML17303A739)
- 05000528/LER-1987-028, :on 871217,inability to Meet Tech Spec Requirements Encountered Due to Failure to Retain Monitor Samples.Caused by Personnel Error.Technician Disciplined & Chemistry Dept Will Receive Training + (ML17303A740)
- ML17303A742 + (ML17303A742)
- 05000530/LER-1987-004-02, :on 871217,w/reactor at 50% Test Plateau During Power Ascension Testing,Reactor Trip Occurred.Caused by Malfunctioning Logic Sequencer Card in Control Element Drive Mechanism Control Sys.Card Replaced + (ML17303A743)
- ML17303A744 + (ML17303A744)
- ML17303A746 + (ML17303A746)
- IR 05000528/1987040 + (ML17303A747)
- ML17303A748 + (ML17303A748)
- ML17303A749 + (ML17303A749)
- ML17303A750 + (ML17303A750)
- ML17303A754 + (ML17303A754)
- ML17303A757 + (ML17303A757)
- ML17303A762 + (ML17303A762)
- ML17303A766 + (ML17303A766)
- ML17303A767 + (ML17303A767)
- L-2017-168, Response to Fourth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed + (ML17303A768)
- ML17303A769 + (ML17303A769)
- ML17303A770 + (ML17303A770)
- 05000528/LER-1988-005, :on 880123,backhoe Operator Inadvertently Damaged Post Indication Valve (Piv)(Kp)(Isv) & Caused Fire Suppression Water to Discharge Into Protected Area.Caused by Inadequate Procedure.Procedures Implemented + (ML17303A771)
- ML17303A772 + (ML17303A772)
- 05000529/LER-1988-005-01, :on 880221,inadvertent Safety Injection from Safety Injection Tanks (Bp)(Acc) Occurred.Caused by Personnel Error.Appropriate Disciplinary Measures Will Be Taken.Malfunctioning Fuse Replaced + (ML17303A773)
- ML17303A777 + (ML17303A777)
- ML17303A778 + (ML17303A778)
- ML17303A779 + (ML17303A779)
- ML17303A783 + (ML17303A783)