- ML17199T431 + (ML17199T431)
- ML17199T432 + (ML17199T432)
- IR 05000407/2017201 + (ML17199T433)
- 05000237/LER-1987-034-01, :on 871016,discovered That Nonconservative Core Thermal Power Calculation Due to Inadequate Calibr Procedure.Rosemount Feedwater Flow Transmitters Recalibr & Listed Procedures to Be Revised + (ML17199T434)
- 05000237/LER-1987-019, :on 860811,reactor Scram Occurred from Main Turbine Trip on High Water Level.Caused by Personnel Error. Event Will Be Reviewed W/All Operators & Action Item Record 12-87-10 Issued to BWR Engineering Dept + (ML17199T435)
- 05000237/LER-1987-032-02, :on 871020,primary Containment Group I Isolation & Reactor Scram Occurred.Caused by Vibration of Main Steam Line Low Pressure Switch.Isolators Installed to Make Switches Less Susceptible to Vibration + (ML17199T438)
- ML17199T439 + (ML17199T439)
- ML17199T440 + (ML17199T440)
- ML17199T441 + (ML17199T441)
- ML17199T443 + (ML17199T443)
- ML17199T444 + (ML17199T444)
- ML17199T445 + (ML17199T445)
- ML17199T446 + (ML17199T446)
- ML17199T447 + (ML17199T447)
- ML17199T448 + (ML17199T448)
- ML17199T450 + (ML17199T450)
- ML17199T451 + (ML17199T451)
- ML17199T454 + (ML17199T454)
- IR 05000237/1987031 + (ML17199T455)
- 05000237/LER-1987-010-01, :on 870317,core Spray Sys a Analytical Piping Stresses Exceeded FSAR Design Requirements.Caused by Design & Const Errors.Sys Analysis Model Revised to Address as-found Condition + (ML17199T457)
- ML17199T459 + (ML17199T459)
- 05000237/LER-1987-033-02, :on 871110,reactor Bldg Ventilation Sys Sample Holder Contained No Particulate Sample Filter.Caused by Personnel Error.New Procedure Written & Sample Filter Replaced + (ML17199T461)
- ML17199T462 + (ML17199T462)
- IR 05000237/1987036 + (ML17199T463)
- ML17199T464 + (ML17199T464)
- ML17199T465 + (ML17199T465)
- ML17199T466 + (ML17199T466)
- IR 05000237/1987037 + (ML17199T467)
- 05000249/LER-1987-005, :on 870316,primary Containment Drywell Structural Steel Failed FSAR Design Requirements.Caused by Inadequate Verification of as-built Condition W/Design Prints During Const.Repair & Insp Planned + (ML17199T468)
- ML17199T469 + (ML17199T469)
- ML17199T472 + (ML17199T472)
- IR 05000237/1987035 + (ML17199T473)
- 05000237/LER-1982-058-03, /03L-1:on 821226,small Leak Found on RWCU Line 2-1201B Between 2-1201-135B & 2-1201-98B Valves.Caused by IGSCC at heat-affected Zone Near Weld.Degraded Pipe Section Replaced Per Work Package D24780 + (ML17199T474)
- ML17199T481 + (ML17199T481)
- IR 05000237/1987039 + (ML17199T482)
- ML17199T485 + (ML17199T485)
- IR 05000237/1987038 + (ML17199T486)
- ML17199T487 + (ML17199T487)
- ML17199T488 + (ML17199T488)
- 05000249/LER-1986-020, :on 861113,spurious Group V Containment Isolation Occurred.Caused by Differential Pressure Spikes &/Or Noise Generated by Annubar Flow Instrument.Mod to Isolation Circuitry Implemented + (ML17199T490)
- 05000249/LER-1986-018-01, :on 861014,spurious Group V Containment Isolation Occurred.Caused by Differential Pressure Spikes &/Or Noise Generated by Annubar Flow Instrument.Mod to Isolation Circuitry Implemented + (ML17199T491)
- ML17199T492 + (ML17199T492)
- 05000249/LER-1983-002-01, /01T-0:on 830105,leakage from RWCU Test Tap Valve 3-1299-13 Occurred.Caused by Seat Damage of Valve.Valve Replaced During 1983 Refueling Outage + (ML17199T526)
- ML17199T557 + (ML17199T557)
- ML17199T592 + (ML17199T592)
- ML17199T632 + (ML17199T632)
- 05000237/LER-1987-035-02, :on 871219,while Responding to APRM 4 hi-hi Alarm,Operator Noted Number of Operable APRM Downscale Trips in Reactor Protection Sys Insufficient.Caused by Personnel Error.Procedure Changed & Operator Counseled + (ML17199T677)
- ML17199T722 + (ML17199T722)
- ML17199T856 + (ML17199T856)
- ML17199T990 + (ML17199T990)
- 05000237/LER-1987-010, :on 870317,discovered Embedment Plate for Support Located on Core Spray Sys a Piping Degraded.Six Addl Discrepancies Found During Review of Sys.Caused by Improper Hold Down Clamp Spacings.Repairs Completed + (ML17199U043)