Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000206/LER-1980-025, Forwards LER 80-025/99X-0 + (ML13331B404)
- 05000206/LER-1980-025-99, /99X-0:on 800505,during Dye Penetrant Insp of Reactor Coolant Pump Flywheel Bores in Refueling Outage, Linear Indications Found in Welds.Cause Unstated.Welds in Bore of Flywheels Installed to Prevent Relative Motion + (ML13331B406)
- 05000206/LER-1980-026, Forwards LER 80-026/01T-0 & Rept Re Automatic Initiation of Auxiliary Feedwater Sys,Per 800513 Meeting W/Nrc + (ML13331B407)
- 05000206/LER-1980-026-01, /01T-0:on 800609,preliminary Results of Main Steam Line Break Accident Scenarios to Determine Containment Response Required Corrective Actions to Reduce Calculated Peak Containment Pressures.Rept Re 800513 Meeting Encl + (ML13331B409)
- 05000206/LER-1980-023, Forwards LER 80-023/03L-0 + (ML13331B410)
- 05000206/LER-1980-023-03, /03L-0:on 800523,during Refueling Outage,Flaw Detected Extending Below Min Wall Thickness in Heat Exchanger E-20B.Caused by Improper Clearance of Previously Repaired Flaw.Flaw Repaired + (ML13331B412)
- 05000206/LER-1980-027, Forwards LER 80-027/03L-0 + (ML13331B414)
- 05000206/LER-1980-027-03, /03L-0:on 800528,radiographic Examination of Feedwater Sys Welds Inside Containment Found Seven Unacceptable Defects Including Lack of Penetration,Porosity & Slag Inclusion.Caused by Original Const Defects + (ML13331B416)
- ML13331B417 + (ML13331B417)
- PNO-V-80-053, on 800619,film Badge Data of Subcontractor Employee Indicated Exposure Exceeding Quarterly limit.Self- Reading Dosimeter Readings Indicated Significantly Lower Exposure.Validity of Data Being Examined + (ML13331B418)
- 05000206/LER-1980-028, Forwards LER 80-028/01T-0 + (ML13331B419)
- 05000206/LER-1980-028-01, /01T-0:on 800612,during IE Bulletin 79-14 Insp, Inadequate Pipe Guides Discovered in Safety Injection Sys Injection Lines.Caused by Improper Installation.Guides Will Be Modified Before Return to Svc + (ML13331B421)
- ML13331B422 + (ML13331B422)
- ML13331B423 + (ML13331B423)
- ML13331B424 + (ML13331B424)
- 05000206/LER-1980-014, Has Been Cancelled + (ML13331B426)
- 05000206/LER-1980-032, Forwards LER 80-032/03L-0 + (ML13331B427)
- 05000206/LER-1980-032-03, /03L-0:on 800717,during Cold Shutdown Conditions, Isolation Valve for Svc Water to Containment Failed to Close Upon Demand.Caused by Small Amount of Desiccant Which Entered Solenoid During Removal of Air Dryer Desiccant + (ML13331B429)
- 05000206/LER-1980-031, Forwards LER 80-031/03L-0 + (ML13331B430)
- 05000206/LER-1980-031-03, /03L-0:on 800728,during Routine Equipment Rotation,South Saltwater Cooling Pump Discharge Valve Failed to Open Automatically.Caused by Installation of Solenoid Valve Operator W/Wrong Size Spring.Valve Replaced + (ML13331B432)
- ML13331B433 + (ML13331B433)
- ML13331B434 + (ML13331B434)
- ML13331B435 + (ML13331B435)
- ML13331B436 + (ML13331B436)
- ML13331B437 + (ML13331B437)
- ML13331B438 + (ML13331B438)
- ML13331B439 + (ML13331B439)
- ML13331B440 + (ML13331B440)
- ML13331B442 + (ML13331B442)
- ML13331B443 + (ML13331B443)
- ML13331B445 + (ML13331B445)
- ML13331B446 + (ML13331B446)
- ML13331B448 + (ML13331B448)
- ML13331B449 + (ML13331B449)
- ML13331B450 + (ML13331B450)
- ML13331B451 + (ML13331B451)
- ML13331B452 + (ML13331B452)
- ML13331B453 + (ML13331B453)
- ML13331B454 + (ML13331B454)
- ML13331B455 + (ML13331B455)
- ML13331B456 + (ML13331B456)
- ML13331B461 + (ML13331B461)
- ML13331B462 + (ML13331B462)
- ML13331B463 + (ML13331B463)
- ML13331B465 + (ML13331B465)
- ML13331B466 + (ML13331B466)
- ML13331B467 + (ML13331B467)
- ML13331B475 + (ML13331B475)
- ML13331B476 + (ML13331B476)
- ML13331B477 + (ML13331B477)
- ML13331B478 + (ML13331B478)