Semantic search

Jump to navigation Jump to search
 Issue dateFromTitleProject stage
ML05006004126 December 1995PSEG
Coward R
H-1-BB-MEE-1050 Hope Creek Recirculation System Large Bore Pipe Cracking Resolution, 12/26/1995Other
ML05014023612 July 2002Tennessee Valley Authority
Wade G
Reactor Coolant Pump Shaft Cracking, July 12, 2002Other
ML05006002515 April 2003- No Known Affiliation
Walsh P
Morrison J
Nagy G
CR 70029861 Hope Creek 'B' Recirculation Pump Excessive Seal Leakage Condition Report, 03/01/2003Other
ML0501402987 May 2003PSEGDrawing 1 of 2, M-43-1 P&Id, Reactor Recirculation SystemOther
ML05014025329 April 2004PSEGHC-04Q-301 Hope Creek Extended Power Uprate Piping Vibration Monitoring, 4/29/2004Other
ML0500603847 September 2004PSEGC-0031 Piping Code Compliance, 9/7/2004Other
ML05006005419 October 2004Public Service Electric & Gas CoDesign Change Package 80062466 Revision 1 Extended Power Uprate Piping Vibration Monitoring Installation Package, 10/19/2004Other
ML05014024726 October 2004Flowserve CorpFlowserve RAL-7483 Rev 0 Design Modification Report Assy 93-14347, 10/26/2004Other
ML05014024526 October 2004Flowserve CorpFlowserve RAL-7482 Rev 0 Design Modification Report Assy 93-15122, 10/26/2004Other
ML05006038729 October 2004PSEG
Barkhamer J
H1BC-1-BC-V183 (CR 20208920) Handwheel Operator Spins Freely, 11/08/2004Other
ML05005011230 October 2004PSEG
Baban T
Klass K
Lasala P
HC.OP-SO.BB-0002(Q) Rev 50A Reactor Recirculation System Operating Procedures, 10/30/2004Other
ML05005011630 October 2004PSEG
Baban T
Klass K
Lasala P
HC-OP-AR.ZZ-0008(Q), Rev 25A, Overhead Annunciator Window Box C1, Operations Alarm Response Procedure, 10/30/2004Other
ML0500600743 November 2004Structural Integrity Associates
Barkhamer J
Structural Integrity Associates, Inc. HC-06-301 Hope Creek Recirculation System Vibration Testing (Vtd 326747) 11/03/2004Other
ML04323016318 November 2004Geoffrey Miller
NRC/NRR/DLPM/LPD1
Expected Task Interface Agreement to Review 'B' Recirculation Pump High Vibration ReportOther
ML05006011010 December 2004Public Service Electric & Gas CoDesign Change Package 80062466 Revision 2 Extended Power Uprate Piping Vibration Monitoring Installation Package, 12/10/2004Other
ML05005011112 December 2004PSEG
Andrea Johnson
Keck B
H-1-FD-CEE-1879, Hope Creek HPCI Exhaust Piping Supports Analysis Reported Damage in RF12.Other
ML05014023212 December 2004- No Known Affiliation
Thomas Greene
Koppel P
Seibold G
H-1-BB-MEE-1878, Rev 0, Hope Creek 'B' Recirculation Pump Vibration Analysis, 12/12/2004Other
ML04348016413 December 2004Daniel Collins
NRC/NRR/DLPM/LPD1
Questions Regarding 'B' Recirculation Pump High Vibrations and High Pressure Coolant Injection System Exhaust DamageRequest
ML05005047016 December 2004PSEGH-1-BB-MEE-1878, Hope Creek 'B' Recirculation Pump Vibration Analysis, Revision 1Other
ML04350064516 December 2004Daniel Collins
NRC/NRR/DLPM/LPD1
Pseg'S Preliminary Responses to NRC Staff Questions Regarding 'B' Recirculation Pump VibrationOther
ML04351027916 December 2004PSEGPSEG Preliminary Responses to NRC Staff QuestionsOther
ML05021006817 December 2004Robert Fretz
NRC/NRR/DLPM/LPD1
Hope Creek Generating Station - Summary of Meeting with PSEG to Discuss B Recirculation Pump High Vibrations (TAC MC5111), Attendance SheetMeeting
ML05006011423 December 2004Public Service Electric & Gas CoDesign Change Package 80062466 Revision 3 Extended Power Uprate Piping Vibration Monitoring, Installation Package, 12/23/2004Other
ML04365029630 December 2004Daniel Collins
NRC/NRR/DLPM/LPD1
Public Availability and Docketing of DocumentsOther
ML05006002230 December 2004- No Known Affiliation'B' Recirculation Pump Stuffing Box Measurements SummaryOther
ML05006025230 December 2004PSEGSummary of Hope Creek Vibration Issues and Planned ActionsOther
ML05006025630 December 2004PSEG'B' Reactor Recirculation Pump Vibration Troubleshooting SummaryOther
ML05012025512 January 2005NRC/NRR/DLPM
Lyons J
Response to Task Interface Agreement - TIA 2004-006, Request for Evaluation of Sargent and Lundy Report on Hope Creek 'B' Reactor Recirculation Pump and PSEG Nuclear LLC Evaluation of High Pressure Coolant Injection System Exhaust SnubbersAcceptance Review
ML05012030312 January 2005Daniel Collins
NRC/NRR/DLPM/LPD1
Flowserve Response to NRC Questions Station 'B' Recirculation PumpOther
ML05003016019 January 2005Ed Miller
Robert Fretz
NRC/NRR/DLPM/LPD1
Hope Creek Generating Station - Summary of Meeting with PSEG to Discuss B Recirculation Pump High VibrationsMeeting