ML23321A236 | 14 December 2023 | Issuance of Amendment Nos. 262 and 224 Adoption of TSTF-477, Revision 3 and Associated Technical Specification Changes | Safe Shutdown Internal Flooding Probabilistic Risk Assessment FLEX Surveillance Frequency Control Program Recently irradiated fuel |
ML23089A124 | 17 May 2023 | Issuance of Amd Nos. 261 & 223 Alternate Seismic Approach for Risk-Informed Categorization and Treatment of Structures, Systems a Components for NPR and Denial Proposed Alternative Defense in Depth and Pressure Boundary Component | |
ML22272A037 | 3 January 2023 | Issuance of Amendment Nos. 258 and 220 Regarding Technical Specifications 3/4.8.1, AC Sources-Operating and 3/4.5.1, ECCS-Operating | Stroke time Incorporated by reference Surveillance Frequency Control Program Power change |
ML22090A086 | 29 April 2022 | Amendments to Adopt TSTF-541,Rev.2,Add Exceptions to Surveillance Requirements for Valves,Dampers Locked in Actuated Position | Safe Shutdown Water Inventory Control Cyber Security Surveillance Frequency Control Program Safeguards Contingency Plan Recently irradiated fuel Fire Protection Program |
RS-22-049, Constellation Energy Generation, LLC, Supplemental Information to Correct Typographical Errors in Constellation'S Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for | 4 April 2022 | Constellation Energy Generation, LLC, Supplemental Information to Correct Typographical Errors in Constellation'S Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for V | |
ML21347A038 | 13 January 2022 | Issuance of Amendments to Revise Reactor Coolant Leakage Requirements | Packing leak Cyber Security Pressure and Temperature Limits Report Surveillance Frequency Control Program Process Control Program Safeguards Contingency Plan Pressure Boundary Leakage Fire Protection Program Unidentified leakage |
ML21181A044 | 28 September 2021 | Issuance of Amendment Nos. 253 and 215 Technical Specification Changes Related to Relocation of Pressure and Temperature Limit Curves to the Pressure and Temperature Limits Report | Shutdown Margin Anticipated operational occurrence Hydrostatic Pressure and Temperature Limits Report Surveillance Frequency Control Program Process Control Program Pressure Boundary Leakage |
JAFP-21-0089, Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position | 27 September 2021 | Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position | Safe Shutdown Reactor Vessel Water Level Ultimate heat sink Stroke time Water Inventory Control Surveillance Frequency Control Program Operability Determination Control of Heavy Loads Fuel cladding Recently irradiated fuel Scaffolding |
ML21032A270 | 22 February 2021 | Issuance of Amendment Nos. 252 and 214, Revise Technical Specifications to Adopt Technical Specifications Task Force Traveler TSTF-582, Revision 0, RPV WIC Enhancements | Reactor Vessel Water Level Water Inventory Control Surveillance Frequency Control Program Fuel cladding |
ML21013A005 | 4 February 2021 | Issuance of Amendments to Adopt Technical Specifications Task Traveler TSTF-568, Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2 | Cyber Security Surveillance Frequency Control Program Safeguards Contingency Plan Fire Protection Program |
ML20239A725 | 30 November 2020 | Issuance of Amendment Nos. 249 and 211 Adopt TSTF-484, Revision 0, Use of TS 3.10.1 for Scram Time Testing Activities | Anticipated operational occurrence Hydrostatic |
ML20178A514 | 26 June 2020 | TS Change and Relief Requests Related to Safety Relief Valve Testing - Response to Request for Additional Information | Surveillance Frequency Control Program |
ML20034F637 | 28 February 2020 | Issuance of Amendment Nos. 240 and 203 to Implement TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4B | Safe Shutdown High winds Reactor Vessel Water Level Ultimate heat sink Anticipated operational occurrence Tornado Missile Internal Flooding Probabilistic Risk Assessment Multiple Spurious Operation FLEX Tornado Generated Missile Fukushima Dai-Ichi Surveillance Frequency Control Program Scram Discharge Volume Large early release frequency Earthquake Maintenance Rule Program Hardened vent Fuel cladding Offsite Circuit Backfit |
ML19207A006 | 3 October 2019 | Issuance of Amendment Nos. 237 and 200 Revise Technical Specifications to Allow Penetration Flow Path Isolation for Inoperable Isolation Actuation Instrumentation | Reactor Vessel Water Level Anticipated operational occurrence Probabilistic Risk Assessment Recently irradiated fuel |
ML19078A018 | 24 May 2019 | Issuance of Amendment Nos. 235, 198, 14, 325, and 328 to Revise the Emergency Response Organization Staffing Requirements | Health Physics Network Severe Accident Management Guideline Minimum staff Fire Protection Program |
ML19029B249 | 12 February 2019 | Correction to Amendment No. 195 Revising Technical Specifications to Lower the Minimum Standby Liquid Control System Pump Flowrate | Surveillance Frequency Control Program |
ML19030A147 | 30 January 2019 | Supplemental Information Needed for Acceptance of Requested Licensing Action to Adopt Risk-Informed Completion Times in Accordance with TSTF-505, Revision 2 | Internal Flooding Probabilistic Risk Assessment Large early release frequency |
RS-18-020, Application to Revise Technical Specifications to Modify the APRM Channel Adjustment Surveillance Requirement | 15 June 2018 | Application to Revise Technical Specifications to Modify the APRM Channel Adjustment Surveillance Requirement | Surveillance Frequency Control Program |
ML18017A201 | 27 February 2018 | Issuance of Amendment Nos. 227 and 190 Revising Technical Specifications to Adopt TSTF-542, Revision 2, Reactor Pressure Vessel Water Inventory Control (CAC Nos. MF9967 and MF9968; EPID L-2017-LLA-0260) | Shutdown Margin Reactor Vessel Water Level Grab sample Stroke time Anticipated operational occurrence Water Inventory Control Probabilistic Risk Assessment Surveillance Frequency Control Program Fuel cladding Recently irradiated fuel |
ML17200D096 | 19 July 2017 | Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control, Rev. 2. | Safe Shutdown Shutdown Margin Reactor Vessel Water Level Grab sample Stroke time Water Inventory Control Hydrostatic Operating Basis Earthquake Surveillance Frequency Control Program Power Operated Valves Fuel cladding Recently irradiated fuel Scaffolding |
ML17103A081 | 16 May 2017 | Issuance of Amendments to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-545 | Time of Discovery Packing leak Incorporated by reference Missed surveillance Pressure Boundary Leakage |
ML16335A038 | 29 December 2016 | Issuance of Amendments to Revise Technical Specification Snubber Requirements | Incorporated by reference Surveillance Frequency Control Program |
ML16041A021 | 15 March 2016 | Issuance of Amendment Safety Limit Minimum Critical Power Ratio Change | Safety Limit Minimum Critical Power Ratio Anticipated operational occurrence Fuel cladding |
ML15356A140 | 28 January 2016 | Issuance of Amendments Secondary Containment Access Openings | Shutdown Margin Surveillance Frequency Control Program Recently irradiated fuel |
ML15218A501 | 15 September 2015 | Issuance of Amendment Nos. 219 and 181 Proposed Change to Add New Limiting Conditions for Operation 3.0.5 and 3.0.6 | Safe Shutdown Offsite Dose Calculation Manual Process Control Program Fire Protection Program |
ML15141A058 | 28 July 2015 | Issuance of Amendments Regarding Emergency Action Level Schemes (TAC Nos. MF4232-MF4251) | Fuel cladding |
ML15083A403 | 11 May 2015 | Issuance of Amendments Adoption of Technical Specification Task Force (TSTF) Traveler TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation | Hydrostatic Surveillance Frequency Control Program |
ML14344A681 | 7 January 2015 | Issuance of Amendments - Main Steam Line Flow-High Isolation Response Time | Reactor Vessel Water Level Anticipated operational occurrence |
ML14324A808 | 29 December 2014 | Issuance of Amendments - Leak Detection System Setpoint and Allowable Value Changes | Reactor Vessel Water Level Anticipated operational occurrence |
ML14308A144 | 3 November 2014 | License Amendment Request Proposed Change to Add New Limiting Conditions for Operations 3.0.5 and 3.0.6 | Process Control Program |
ML052780034 | 20 October 2014 | Current Facility Operating License NPF-39, Technical Specifications, Revised 08/15/2018 | Safe Shutdown Time of Discovery Shutdown Margin Reactor Vessel Water Level Packing leak High Radiation Area Ultimate heat sink Grab sample Offsite Dose Calculation Manual Water Inventory Control Internal Flooding Hydrostatic Probabilistic Risk Assessment Squib Cyber Security Incorporated by reference Annual Radioactive Effluent Release Report Surveillance Frequency Control Program Scram Discharge Volume Annual Radiological Environmental Operating Report Process Control Program Excess Flow Check Valve Safeguards Contingency Plan Overtravel License Renewal Deep Dose Equivalent Biofouling Pressure Boundary Leakage Recently irradiated fuel Offsite Circuit Fire Protection Program Unidentified leakage |
ML14191B180 | 10 July 2014 | Application to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Using the Consolidated Line Item Improvement Process | Safe Shutdown Reactor Vessel Water Level Surveillance Frequency Control Program Fuel cladding |
ML13214A092 | 26 March 2014 | Issuance of Amendments Elimination of Certain Technical Specifications Reporting Requirements | Safe Shutdown Annual Radioactive Effluent Release Report Surveillance Frequency Control Program Annual Radiological Environmental Operating Report Fuel cladding Fire Protection Program |
ML13100A020 | 9 April 2013 | License Amendment Request to Eliminate Certain Technical Specifications Reporting Requirements | Surveillance Frequency Control Program Annual Radiological Environmental Operating Report |
ML113180238 | 10 November 2011 | Response to Request for Additional Information Concerning the License, Amendment Request Associated with the Reactivity Anomalies Surveillance | |
ML112870080 | 12 October 2011 | License Amendment Request - Safety Limit Minimum Critical Power Ratio Change | Minimum Critical Power Ratio |
ML111710007 | 14 June 2011 | License Amendment Request to Include an Alternate Method of Verifying Drywell Unidentified Leakage | Unidentified leakage |
ML111540120 | 2 June 2011 | License Amendment Request - Reactivity Anomalies Surveillance | Shutdown Margin Anticipated operational occurrence Process Control Program Pressure Boundary Leakage Recently irradiated fuel |
ML110970066 | 6 April 2011 | License Amendment Request to Revise Operability Requirements and Actions for RCS Leakage Instrumentation | |
ML103500180 | 15 December 2010 | License Amendment Request - Safety Limit Minimum Critical Power Ratio Change | Safety Limit Minimum Critical Power Ratio Anticipated operational occurrence Abnormal operational transient MELLLA Fuel cladding |
ML103060379 | 29 October 2010 | Response to Request for Additional Information, License Amendment Request, Proposed Technical Specification Allowed Outage Time Extensions to Support Residual Heat Removal Service Water Maintenance | Safe Shutdown High winds Tornado Missile Probabilistic Risk Assessment Operator Manual Action Multiple Spurious Operation Surveillance Frequency Control Program Large early release frequency |
ML102430466 | 31 August 2010 | License Amendment Request, Proposed Administrative Changes to Technical Specifications | Shutdown Margin |
ML101810434 | 30 June 2010 | License Amendment Request - Table 3.3.2-2, Item 4e, HPCI Equipment Room Delta Temperature High Isolation Trip Setpoint and Allowable Value Changes | Reactor Vessel Water Level Mission time Anticipated operational occurrence |
ML100850395 | 25 March 2010 | Markup of Proposed Operating License, Technical Specifications & Updated Final Safety Analysis Report Pages | Safe Shutdown Boric Acid Reactor Vessel Water Level Squib Surveillance Frequency Control Program Scram Discharge Volume Recently irradiated fuel Fire Protection Program |
ML091280059 | 17 April 2009 | Changes to Technical Specifications Bases, Including Changes Through 04/09/2009 | Safe Shutdown Time of Discovery Shutdown Margin Reactor Vessel Water Level Safety Limit Minimum Critical Power Ratio Packing leak High Radiation Area Ultimate heat sink Grab sample Offsite Dose Calculation Manual Fire Barrier Stroke time Anticipated operational occurrence Hydrostatic Squib Missed surveillance Abnormal operational transient Annual Radioactive Effluent Release Report Surveillance Frequency Control Program Scram Discharge Volume Annual Radiological Environmental Operating Report Process Control Program Feedwater Controller Failure MELLLA Excess Flow Check Valve Fast acting solenoid valve Operability Determination Safeguards Contingency Plan Battery sizing Overtravel Deep Dose Equivalent Fuel cladding Biofouling Pressure Boundary Leakage Recently irradiated fuel Offsite Circuit Continuous fire watch Fire Protection Program Fire Watch Hourly Fire Watch Early Warning Fire Detection Grace period Unidentified leakage Failure to Scram |
ML082470305 | 28 August 2008 | Technical Specifications, TSTF Change Traveler TSTF-479 & TSTF-497 | Safe Shutdown Time of Discovery Safeguards Contingency Plan Fire Protection Program Scaffolding |
ML082120730 | 27 August 2008 | Tech Spec Pages for Amendment 154 Increase in Emergency Diesel Generator Day Tank Minimum Fuel Volume | Safe Shutdown Fire Protection Program |
ML081780254 | 5 August 2008 | Technical Specifications, Limerick Unit 1, Amendment 192, License NPF-39 | Shutdown Margin High Radiation Area Grab sample Offsite Dose Calculation Manual Surveillance Frequency Control Program Scram Discharge Volume Process Control Program Overtravel Pressure Boundary Leakage Recently irradiated fuel |
ML081780287 | 5 August 2008 | Technical Specifications, Limerick Unit 2, Amendment 153, License NPF-85 | Safe Shutdown Shutdown Margin High Radiation Area Grab sample Offsite Dose Calculation Manual Annual Radioactive Effluent Release Report Surveillance Frequency Control Program Scram Discharge Volume Process Control Program Pressure Boundary Leakage Recently irradiated fuel Fire Protection Program |
ML081630558 | 11 June 2008 | Supplement to License Amendment Request Related to Proposed Changes to Emergency Diesel Generator Fuel Oil Requirements | Safe Shutdown |