ML20211C33130 April 1999Rev 2.0 to Generic ODCM for Dresden,Quad Cities,Zion, Lasalle,Byron & BraidwoodOffsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Deep Dose Equivalent
ML20202G93630 January 1999Rev 1.4 to Chapter 10, Radioactive Effluent Treatment & Monitoring, Rev 1.6 to Chapter 11, Radiological Environ Program & Rev 1.6 to Chapter 12, Radioactive Effluent Technical Standards (Rets), for Odcm,Byron AnnexGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
B.5.b Mitigating Strategies
Deep Dose Equivalent
Power change
ML20153C03531 August 1998Revs to ODCM for Plant,Including Rev 2 to Chapters 10 & 11, Rev 4 to Chapter 12 and Rev 3 to App FGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Deep Dose Equivalent
Power change
ML20238F82225 August 1998Rev 2 to Braidwood Station Units 1 & 2 Second Interval ISI Program PlanCoatings
ML20236Y5483 August 1998Rev 1 to Braidwood Station Units 1 & 2 Second Interval ISI Program PlanBoric Acid
High Radiation Area
Hydrostatic
Coatings
VT-2
Scaffolding
ML20217Q8521 May 1998Rev 9 to Bzp 310-2, Nuclear Accident Reporting Sys Form (Primary Responsibility - Station Director). W/Notes & CommentsNuclear Accident Reporting System
ML20216C10126 March 1998Revs to ODCM for Braidwood,Including Rev 1.9 to Chapter 10 & Rev 3 to Chapter 12Grab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Deep Dose Equivalent
Power change
ML20217C30131 January 1998Rev 0 to Inservice Testing Program Plan Pumps & Valves Braidwood Nuclear Generating Station,Units 1 & 2Safe Shutdown
Boric Acid
High Radiation Area
Stroke time
Weld Overlay
Cold shutdown justification
Power-Operated Valves
Power Operated Valves
Scaffolding
ML20199J75831 December 1997Rev 1 to IST Plan Pumps & Valves Byron Nuclear Generating Station,Units 1 & 2Boric Acid
Ultimate heat sink
Stroke time
Weld Overlay
Cold shutdown justification
Power-Operated Valves
Power Operated Valves
Scaffolding
ML20216H43231 December 1997Revs to OCDM for Braidwood,Including Rev 1.8 to Chapter 10, Rev 1.9 to Chapter 11,rev 2 to Chapter 12 & Rev 2 to App FGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Power change
ML20216H82431 October 1997Revs to OCDM for Byron Station,Including Rev 1.3 to Chapter 10,rev 1.5 to Chapters 11 & 12 & Rev 1.3 to App FGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Deep Dose Equivalent
Power change
ML20198M26231 October 1997Revs to Offsite Dose Calculation Manual,Consisting of Rev 1.5 to Chapter 11 & Rev 1.5 to Chapter 12Offsite Dose Calculation Manual
ML20198P16020 October 1997Rev 1.5 to Odcm,Chapter 12Grab sample
Offsite Dose Calculation Manual
ML20216H70110 September 1997Revised Procedures,Including Rev 2 to Bwzp 2000-18, Post- Accident Sampling Sys (Primary Responsibility - Chemistry Director) & Rev 2 to Bwzp 2000-18A1, PASS Sample Collection Procedures
ML20137B92228 February 1997Revs 1.3 to Chapter 10, Radioactive Effluent Treatment & Monitoring, 1.4 to Chapter 11, Radiological Environ Monitoring Program & 1.4 to Chapter 12, Radioactive Effluent Technical Standards, Odcm,Byron AnnexGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Deep Dose Equivalent
Power change
ML20137A49631 December 1996Rev 2 to Odcm,Braidwood Annex,Chapter 12 & App FGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Deep Dose Equivalent
Power change
ML20116L46912 August 1996Rev 1 to 1595-00305.30000, Byron Station Units 1 & 2 Second Interval Inservice Insp Program Plan-NRC SubmittalBoric Acid
High Radiation Area
Non-Destructive Examination
Hydrostatic
Nondestructive Examination
VT-2
Incorporated by reference
Liquid penetrant
Scaffolding
ML20116F38130 June 1996Rev 1.9 to ODCM, Chapters 11,12 & App FGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Deep Dose Equivalent
Power change
ML20100Q17631 March 1996Rev 1.3 to OdcmGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Deep Dose Equivalent
Power change
ML20134N30525 March 1996Rev 1 to 10CFR50.59 SeBoric Acid
Turbine Missile
ML20095J61331 December 1995Rev 0 of IST Plan Pumps & Valves Byron Nuclear Generating Station Units 1 & 2Boric Acid
Ultimate heat sink
Stroke time
Weld Overlay
Probabilistic Risk Assessment
Cold shutdown justification
Power-Operated Valves
Power Operated Valves
Scaffolding
ML20095A90731 October 1995Rev 1.8 to OdcmGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Power change
ML20129B70522 September 1995Rev 0 to Byron/Braidwood Units 1 & 2 SG Eddy Current Analysis Guidelines
ML20092B1052 September 1995Rev 0 to SG Structural Insp Plan in Support of Braidwood 1 & Byron 1 3.0 Volt IpcScaffolding
ML20091M86425 August 1995Verification Analysis for Computer Program
ML20082L54518 April 1995Rev 3 to ISI Plan for Braidwood Nuclear Generating Station Units 1 & 2 1st Insp IntervalBoric Acid
Non-Destructive Examination
Hydrostatic
Nondestructive Examination
VT-2
Liquid penetrant
Scaffolding
ML20082C94814 March 1995Rev 7 to IST Program Plan for Pumps & ValvesSafe Shutdown
Boric Acid
Shutdown Margin
High Radiation Area
Stroke time
Weld Overlay
Cold shutdown justification
Power-Operated Valves
Power Operated Valves
Scaffolding
ML20072R4119 September 1994Rev 13 to IST Program Plan for Pumps & ValvesBoric Acid
Stroke time
Cold shutdown justification
Power-Operated Valves
Power Operated Valves
Scaffolding
ML20076L74631 August 1994Rev 1.2 to Odcm,Chapters 10,11,12 & App FGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Deep Dose Equivalent
Power change
ML20072Q19729 August 1994Proposed Rev 0a to Section 7 of ISI Program Plan for Pressure TestingNon-Destructive Examination
Hydrostatic
VT-2
ML20083N87031 July 1994Rev 7 to Byron & Braidwood Stations Units 1 & 2 Eddy Current Analyis Guidelines
ML20064H91011 March 1994Rev 12 to Section 4.0 of IST Program Plan for ValvesBoric Acid
Stroke time
Power-Operated Valves
Power Operated Valves
ML20064H90111 March 1994Rev 10 to Section 3.0 of IST Program Plan for PumpsBoric Acid
ML20063F87231 January 1994Rev 1.0 to Chapters 10,11,12 & App F to Odcm,Byron StationGrab sample
Offsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Power change
ML20063F89631 January 1994Rev 1.0 to Chapters 10,11,12 & App F to Odcm,Braidwood Station
ML20064N32820 December 1993Rev 0 to Operating Parameter Uncertainties for Byron/ Braidwood Revised Thermal Design Procedure
ML20056C74430 June 1993Rev 0.M to ODCM Chapters 10,11 & 12 for Braidwood StationGrab sample
Offsite Dose Calculation Manual
Annual Radiological Environmental Operating Report
ML20046C79425 June 1993Idns Map Monitoring Point Id for Braidwood Station, Tables H & I
ML20062N7851 March 1993Rev 4.1 to Procedure Bwhp 4006-008, Repairing, Determinating,Terminating,Splicing,Taping,Cable Jacket Repair & Application of Ray Chem Kit on Cable
ML20127D06930 December 1992Corporate Emergency Response Organization Required Reading Package 92-11
ML20058E86829 September 1992Rev 56A to AOP 1BOA PRI-5, Control Room Inaccessibility Unit 1
ML20101M21925 June 1992Rev 5 to Inservice Testing Program Plan for Pumps Braidwood Station Units 1 & 2Safe Shutdown
Boric Acid
High Radiation Area
Stroke time
Power-Operated Valves
Power Operated Valves
ML20098D74331 May 1992Rev 0.G to ODCM Chapter 11,pages 11.i,11-5,11-6,11-7 & 11-7, Figure 11-3Offsite Dose Calculation Manual
ML20101B03021 April 1992Corrected Rev 0.F to Page 11-19 of Chapter 11 of ODCM
ML20090A85427 February 1992Rev 11 to Section 4.0 of Inservice Testing Program Plan for ValvesBoric Acid
Stroke time
Power-Operated Valves
Power Operated Valves
ML20090H76527 February 1992Rev 0.D to Odcm
ML20092F2256 February 1992Rev O.F to Chapter 11,Pages 11-i,11-7 & 11-17 of ODCM
ML20092J4093 February 1992Rev 25 to Block Index Procedure Bwzp 600-3A1,App a, Federal Agency Emergency Support Phone List
ML20058E87618 November 1991Rev 56 to AOP Bwoa PRI-10, Loss of Rh Cooling Unit 1
ML20082S8007 September 1991Rev 54 to 1BWOA PRI-10, Loss of Residual Heat Cooling,Unit 1Boric Acid