ML20042F3264 May 1990LER 90-005-00:on 900404,intergranular Attack & IGSCC Results in Both Steam Generators a & B Being Categorized as C-3.All Defective Tubes Plugged & Sludge Lancing & Crevice Flushing conducted.W/900504 LtrBoric Acid
ML20024B7221 July 1983LER 83-015/03L-0:on 830606,during Valve Timing Test for Td Auxiliary Feedwater Pump,Valve Failed to Electrically Open. Caused by Faulty Torque Switch & Maladjusted Tripper Cam. Valve Operator Rebuilt & Cam reset.W/830701 Ltr
ML20024B7291 July 1983LER 83-014/03L-0:on 830603,while Performing Monthly RHR Pump & Valve Surveillance Test,Containment Sump B Isolation Valve SI-350B Would Not Cycle Closed.Caused by Mechanical Interlock Sticking in Open position.W/830701 Ltr
ML20023C3686 May 1983Updated LER 82-030/01X-2:on 821004,sensing Lines on Six safety-related Containment Pressure Transmitters Found Capped Off Inside Containment.Caused by Personnel Error During Maint.Caps Removed
ML20028F43614 January 1983LER 82-035/03L-1:on 821216,during Full Power Operation, Pinhole Leak Discovered in Suction Line from Vol Control Tank to Charging Pumps.Caused by Vibrations & Pulsations in Associated Piping.Leak Plugged
ML20028E38214 January 1983LER 82-035/03L-0:on 821216,pinhole Leak Discovered in Suction Line from Vol Control Tank to Charging Pumps.Caused by Vibrations in Piping.Leak Plugged & Piping to Be Replaced During Next Refueling Outage
ML20052G73510 May 1982LER 82-009/03L-0:on 820410,w/unit at Hot Shutdown Prior to Scheduled Refueling Outage,Both Source Range Nuclear Instruments Were Inoperable.Caused by Accumulation of Water in Instrument Canisters.Spare Detector Installed
ML20052G1386 May 1982LER 82-008/01T-0:on 820422,during Refueling Outage,Leak Repair Procedures on Valve SI-13B Revealed Significant Boric Acid Corrosion Wastage of body-to-bonnet Bolts.Caused by Bolt Degradation.Affected Bolts ReplacedBoric Acid
ML20052G1406 May 1982LER 82-007/01T-0:on 820422,during Refueling Outage,Leak Repair Procedures on Valve PS-1A Revealed Significant Boric Acid Corrosion Wastage on body-to-bonnet Bolts.Caused by Bolt Degradation.Affected Bolts ReplacedBoric Acid
ML20052G7257 April 1982LER 82-005/03X-1:on 820309,during Quarterly Surveillance Testing of Svc Water pumps,IA2 Svc Water Pump Failed to Start on Demand.Circuit Breaker Failed to Close by Remote Initiation.Caused by Failed Open Closing Coil.Coil Replaced
ML20041B37915 February 1982LER 82-003/03L-0:on 820116,1A Zone SV Fan Started Automatically.Caused by Solenoid Valve Failure Due to Burned Out Coil in Closed Position Which Automatically Opened Damper.Coil Replaced & Sys Tested Satisfactorily
ML20041B36012 February 1982LER 82-002/03L-0:on 820114,deviation in Pressurizer (Pzr) Level Indication Noted.Caused by Instrument Calibr Out of Spec.Transmitter Recalibr
ML20040G6085 February 1982LER 82-001/03L-0:on 820108,during Operability Check of Zone Special Ventilation,Exhaust Fan 1B Failed to Start.Caused by Failure of Solenoid Valve Due to Sticking Solenoid.Valve Replaced & Sys Tested.Design Change Initiated
ML20040F3571 February 1982LER 81-039/03X-1:on 811218,leaking Weld on Discharge Side of 1C Charging Pump Relief valve,CVC-101C,discovered.Caused by Vibrations & Pulsations in Associated Piping.Pipe Section Replaced.Design Change in Progress
ML20040A57715 January 1982LER 81-039/03L-0:on 811218,found Leaking Weld on Discharge Side of 1C Charging Pump Relief Valve CVC-101C.Caused by Weld Fatigue Attributed to Vibrations & Pulsations in Associated Piping.Pipe Replaced.Design Change in Progress
ML20039B18311 December 1981LER 81-038/03L-0:on 811113,during Surveillance Testing on Shield Bldg Vent Sys,Check Damper SBV-10A Failed Shut.Caused by Ruptured Diaphragm Which Separates Motor from Oil Reservoir.Motor Replaced
ML20038C2623 December 1981LER 81-036/03L-0:on 811103,motor-driven Auxiliary Feedwater Pump Lubricator Oil Pump Continued to Run When Pump 1A Was Stopped.Caused by Excessive Wear & Misalignment of Auxiliary Switch Linkage Mechanism Allowing Switch to Remain Closed
ML20038B00117 November 1981LER 81-034/03L-0:on 811018,during Normal operations,1B Zone SV Fan Started Automatically.Caused by Solenoid Failure Due to Burned Out Coil in Safe Position Automatically Starting Fan & Opening Damper.Coil Replaced
ML20038B02216 November 1981LER 81-015/03L-2:on 810510,during Refueling Shutdown,Steam Flow Transmitter Was Out of Calibr Resulting in Less Conservative Hi & hi-hi Steam Flow than Required.Caused by Instrument Drift
ML20011A5522 October 1981LER 81-030/03L-0:on 810903,surveillance Procedure Found to Incorrectly Measure Shield Bldg Vent Sys Exhaust Flow from Annulus.Caused by Surveillance Procedures Written to Demonstrate Original Design Criteria
ML20010F50728 August 1981LER 81-024/03L-0:on 810730,low Boric Acid Heat Tracing Temp Detected on Section of Piping Between Boric Acid Tanks & Safety Injection Pumps.Caused by Removal of Insulation from Boric Acid Heat Tracing Circuits to Permit MaintBoric Acid
ML20010F34228 August 1981LER 81-025/03L-0:on 810807,safety Injection High Containment Pressure Setpoint Discovered to Be Less Conservative than Required by Tech Spec Due to Foxboro Containment Pressure Transmitter Out of Calibr.Caused by Instrument Drift
ML20009E66221 July 1981LER 81-023/03L-0:on 810621,boric Acid Found Leaking from Instrument Isolation Valve CVC-11188.Caused by Leaking Diaphragm & Corroded Bonnet.Transfer Pump 1A Isolated & Bonnet Assembly ReplacedBoric Acid
ML20009D55317 July 1981LER 81-022/03L-0:on 810619,spent Fuel Pool Boron Sampling Not Performed within Allotted Time Frame During Steady State Operation.Caused by Temporary Work Load Increase on Chemistry Staff.Sample Taken & Analyzed
ML20009C56510 July 1981LER 81-021/03L-0:on 810611,found Visual Verification of Valve Motion & Limit Switch Not Performed During Refueling Outage for Valves Inaccessible During Normal Operation Per Iwv 3300 of 1974 ASME Code.Caused by Procedural Oversight
ML20009A9386 July 1981LER 81-020/03L-0:on 810606,condensate Water Storage Tank Level Went Below Tech Spec Limit.Caused by Normal Tank Water Usage During Startup & Turbine Testing Coincident W/ Demineralizer Regeneration
ML20009A8633 July 1981LER 81-019/03L-0:on 810605,during Refueling Outage,Portable Radiation Survey Instrument Checks for May Not Performed Per Tech Specs.Caused by Oversight Due to Reassignment of Personnel.Instruments Will Be Source Checked in June
ML20009B53815 June 1981LER 81-018/03L-0:on 810516,testing Indicated That Low Pressure Safety Injection & Reactor Trip Were Below Tech Spec Limits for Pressure Transmitters.Caused by Instrument Drift.Sensing Lines Flushed.Amplifier Replaced
ML20009B53512 June 1981LER 81-017/03L-0:on 810515,discovered That High Pressure Reactor Trip Setpoints for Pressure Transmitters Were Higher than Tech Spec.Caused by Setpoint Drift.Instruments Recalibr
ML20009B53312 June 1981LER 81-016/03L-0:on 810515,tests Indicated That Two Foxboro RCS Flow Transmitters in Loop a Were Out of Calibr.Caused by Setpoint Drift.Transmitters Recalibr
ML20004F0169 June 1981LER 81-015/03L-0:on 810510,steam Flow Transmitter Found Out of Calibr Resulting in Bi Steam Flow & hi-hi Steam Flow Trip Settings Less Conservative than Tech Spec.Caused by Instrument Drift.Transmitter Recalibr
ML11166151822 May 1981LER 81-013/03L-0:on 810422,during Facility Shutdown for Leak Rate Test,Investigation Revealed Cracked Root Weld on Vent Valve of Containment Sump B to RHR Pump 1B Piping.Caused by Sharp Blow of Unknown Origin.Repair Scheduled
ML11166150913 April 1981LER 81-010/01T-0:on 810330,nonradioactive Liquid Found Discharged from Waste Neutralizing Tank to Svc Water Pretreatment Lagoon.Caused by Error in Calculation of Allowable Discharge Rates.Proposed Tech Spec Submitted
ML11166148220 February 1981LER 81-003/03L-0:on 810122,supply Thermal Overloads Tripped During Testing of Valve CC400B (Component Cooling Water Inlet to Residual Heat Exchanger 1B).Caused by Wiring Error. Wiring Fault Identified & Corrected
ML11166146028 January 1981LER 80-044/03L-0:on 801229,noted That RCS Oxygen Sample Test Not Performed W/Frequency Required by Tech Specs.Caused by Personnel Error.Personnel Will Be Instructed in Implementation of Procedure
ML19294C03629 February 1980LER 80-005/03X-1:on 800131,during IE Bulletin 79-14 Insp, Discovered That Thermal Restraint Was Omitted from RHR Sys. Caused by Error in Transferring Piping Design to Const Drawings.Restraint Has Been Installed