Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
PNO-II-94-010, on 940225,licensed Reactor Operator Tested Positive During Random Drug Test25 February 1994PNO-II-94-010:on 940225,licensed Reactor Operator Tested Positive During Random Drug TestFitness for Duty
PNO-II-89-064, on 890907,plant Shut Down for More than 48 H to Determine Cause of Out of Spec Secondary Chemistry.Msiv a Test Circuitry Discovered Energized & Valve Declared Inoperable on 890908.Caused by Water Hammer in Flush Line11 September 1989PNO-II-89-064:on 890907,plant Shut Down for More than 48 H to Determine Cause of Out of Spec Secondary Chemistry.Msiv a Test Circuitry Discovered Energized & Valve Declared Inoperable on 890908.Caused by Water Hammer in Flush Line
PNO-II-89-060A, on 890825,reactor Manually Tripped from 97% Power Due to Pressurizer a Safety Valve Lifting.Licensee Plans to Go to Cold Shutdown & Replace Valve.Repairs Expected to Take 1 Wk25 August 1989PNO-II-89-060A:on 890825,reactor Manually Tripped from 97% Power Due to Pressurizer a Safety Valve Lifting.Licensee Plans to Go to Cold Shutdown & Replace Valve.Repairs Expected to Take 1 Wk
PNO-II-89-040, on 890530,rapid RCS Pressure Decreased to Less than 2,000 Psi.Licensee Investigating Incident to Determine Root Cause & Corrective Action.Anticipated That Unit Will Be Down for Approx 2 Wks30 May 1989PNO-II-89-040:on 890530,rapid RCS Pressure Decreased to Less than 2,000 Psi.Licensee Investigating Incident to Determine Root Cause & Corrective Action.Anticipated That Unit Will Be Down for Approx 2 Wks
PNO-II-89-020, on 890214,plant Shut Down Due to Continuing SG Conductivity & Sulphate Problems Associated W/Resin Intrusion Event.During Shutdown Steam Generators Flushed & Mechanically Cleaned Along W/Dearating Tank13 March 1989PNO-II-89-020:on 890214,plant Shut Down Due to Continuing SG Conductivity & Sulphate Problems Associated W/Resin Intrusion Event.During Shutdown Steam Generators Flushed & Mechanically Cleaned Along W/Dearating Tank
PNO-II-88-038, on 880603,outage Exceeded 48 H to Repair Leaking Tubes on Condenser B.Reactor Subsequently Tripped from Unrelated Switch Problem During Surveillance Test.Eddy Current Test Determined 30 Tubes Would Not Pass Probe3 June 1988PNO-II-88-038:on 880603,outage Exceeded 48 H to Repair Leaking Tubes on Condenser B.Reactor Subsequently Tripped from Unrelated Switch Problem During Surveillance Test.Eddy Current Test Determined 30 Tubes Would Not Pass Probe
PNO-II-86-087, on 861107,employee Received Calculated Exposure of 75 Rems to One Hand,Exceeding 10CFR20,18.75 Rems Limit.Cause of Contamination Undetermined.Region II Radiation Specialist Dispatched for Followup20 November 1986PNO-II-86-087:on 861107,employee Received Calculated Exposure of 75 Rems to One Hand,Exceeding 10CFR20,18.75 Rems Limit.Cause of Contamination Undetermined.Region II Radiation Specialist Dispatched for Followup
PNO-II-86-039, on 860531,plant Taken Out of Svc to Repair Damage to non-nuclear Components Caused by Water Hammer in Low Pressure Condensate Sys.Caused by Personnel Error During Restart.Plant Will Be Down for Several Days3 June 1986PNO-II-86-039:on 860531,plant Taken Out of Svc to Repair Damage to non-nuclear Components Caused by Water Hammer in Low Pressure Condensate Sys.Caused by Personnel Error During Restart.Plant Will Be Down for Several Days
PNO-II-85-081, on 850820,during Full Power,Reactor Tripped. Caused by Valving Procedure Error by Technician Replacing Reactor Coolant Loop Flow Transmitter.Source Range Channel Being Replaced.Restart Scheduled for 85082422 August 1985PNO-II-85-081:on 850820,during Full Power,Reactor Tripped. Caused by Valving Procedure Error by Technician Replacing Reactor Coolant Loop Flow Transmitter.Source Range Channel Being Replaced.Restart Scheduled for 850824
ML20249A8121 February 1978PNS-78-006:on 780131 Bomb Threat Was Telephoned to V Summer Unit 1 Switchboard Operator.Search Initiated by Licensee & Nothing Found.Fbi & State of South Carolina Notified
ML20249A04426 January 1978PNO-78-016:on 780125,as Result of Filling Plant Cooling Water Reservior to within 15 Ft of Normal High Water Level, Micro Seismic Activity Was Recorded at 2.5 on Richter Scale of Seismic Monitors Operated by Licensee of State of Sc
ML20151X98814 October 1977PNO-77-183:during Routine Insp in Aug 1977,licensee Discovered Cracks in Reinforced Concrete Svc Water Intake Tunnel.Licensee Evaluation in Progress.Media Interest Not Expected.State of Sc Notified
ML20151X45214 October 1977PN-77-183:during Routine Insp in Aug 1977,licensee Discovered Cracks in Reinforced Concrete Svc Water Intake Tunnel.Licensee Does Not Believe That Extensive Repairs Will Be Required
ML20249A90619 May 1977PNS-77-024:on 770519,bomb Threat Was Phoned Into Sceg Co. Fbi,Sc State Law Enforcement Div & County Sheriff Responding But Not Yet on Site.Search Initiated by Licensee.No Decision Made on Evacuation