ML20059D64428 December 1993Notice of Violation from Insp on 930826-1118.Violation Noted:On 930826,inspector Found Several Examples of High Radiation Areas Where Licensee Did Not Barricade or Properly Control Access to Prevent Inadvertent EntryHigh Radiation Area
ML20197H7156 November 1990Notice of Violation from Insp on 900821-1001.Violation Noted:Corrective Action Implemented as Result of Failures of Emergency Lighting Surveillance Test Failed to Preclude Repetition of FailuresEmergency Lighting
ML20058D28719 October 1990Notice of Violation from Insp on 900802-27.Violation Noted:Failure to Adequately Test EDGs After Major Overhaul
ML20247B08014 July 1989Notice of Violation from Insp on 890410-0521.Violation Noted:Licensee Failed to Properly Restore Circuitry Configuration of Module in Control Room Main Fire Panel During Surveillance Testing
ML20245J77225 April 1989Partially Deleted Notice of Violation from Insp on 890403-07 (Ref 10CFR73.21).Violation Info Withheld
ML20235Y7922 March 1989Notice of Violation from Insp on 881115-890117.Violations Noted:High Radiation Area in Shield Tank Cavity in Vapor Container Not Posted W/Sign or Signs Bearing Radiation Caution Symbol & Words of Warning on 890107High Radiation Area
ML20235J15915 February 1989Notice of Violation from Insp on 881227-30.Violation Noted: Operation of Reactor at Low Power for Indeterminate Periods of Time W/Certain Reactor Protective Sys Power Range Less Conservative than Limiting Safety Sys Settings Required
IR 07100014/200500421 June 1988Notice of Violation from Insp on 880401-0531.Violation Noted:Approved Written Meeting Minutes,Written Approvals or Disapprovals of Required Reviews & Ref Determinations Not Issued for Period 871014-0504
ML20153E07527 April 1988Notice of Violation from Insp on 880110-15.Violation Noted: Fuses in Alarm Bistable Replaced in Kind W/Commercial Grade Fuses Not Purchased in Conformance to Procurement Documents
ML20149J12212 February 1988Notice of Violation from Insp on 871027-880119.Violation Noted:Failure to Notify NRC within 1 H of Initiation of Plant Shutdown
ML20235E90416 September 1987Notice of Violation from Insp on 870511-29.Violation Noted: Licensee Failed to Plug All Steam Generator Tubes Exceeding Tech Spec Plugging Limit
ML20237L80624 August 1987Notice of Violation from Insp on 870615-19.Violation Noted:Worker Contaminated on 870530 W/Radioactive Hot Particle & Util Survey of Hot Particle Inaccurate
ML20214D17212 May 1987Notice of Violation from Insp on 870127-0417
ML20205F87423 March 1987Notice of Violation from Insp on 870127-30
ML20214V5733 December 1986Notice of Violation from Insp on 860929-1003
ML20215M68424 October 1986Notice of Violation from Insp on 860610-1006
ML20206P10119 August 1986Notice of Violation from Insp on 860626-0702.Violations Noted:Reactor Not Placed in Hot Standby & Then Cold Shutdown When Reactor Vessel Head Vent & Pressurizer Steam Space Vent Inoperable
ML20140E79824 March 1986Notice of Violation from Insp on 860107-0214
IR 05000321/20040264 June 1985Notice of Violation from Insp on 850321-0426
ML20054K78118 June 1982Notice of Violation from Insp on 820413-19,0506-07 & 19-28
ML20054G8834 June 1982Notice of Violation from Insp on 820504-07
ML20148F81614 November 1974Description of Violations from Insp on 741022-25