Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML20212L9775 October 1999Notice of Violation from Insp on 990710.Violation Noted:From 990224-0325,River Bend Station Operated in Mode I Without Three Operable EDGsLoctite
ML20199E2117 January 1999Notice of Violation from Insp on 981101-1212.Violation Noted:On 971022,radiation Protection Technicians Released One Container with Two Items Contaminated Above Limits Specified in Procedure RSP-0213
ML20198T0695 January 1999Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Info Was Provided to Senior Resident Inspector That Was Not Complete & Accurate in All Matl Respects Re 971010 of RWP 97-0002
ML20199A2165 January 1999Notice of Violation from Investigation Conducted on 971231. Violation Noted:On 971015,A Wells,Employee on Entergy Operations,Inc,Submitted to NRC Info Known to Be Inaccurate in Some Respect Matl to NRC
ML20198N91529 December 1998Notice of Violation from Insp on 980720-0807.Violation Noted:On 980724,licensee Made Change to Facility as Described in Safety Analysis Rept,Which Created Unreviewed Safety Question,Without Prior Commission Approval
ML20154L70217 August 1998Corrected Notice of Violation from Insp Completed on 980218. Corrected NOV Sent to Make Consistent with Ltr Sent on 980722 & to Make Clear That No Response Required
ML20236V20829 July 1998Notice of Violation from Insp on 980517-0627.Violation Noted:On 980601,while Accomplishing Clearance Order 98-0583, Operator Did Not Follow Sequence Shown on Clearance Order While Positioning Components
ML20154L73522 July 1998Notice of Violation from Investigation Completed on 980218. Violation Noted:On 970711,DL Brown Employee of Contractor to Util Deliberatly Submitted Info to Licensee That Brown Knew Incomplete & Inaccurate on Security Questionnaire
ML20154M55322 July 1998Notice of Violation from Investigation Completed on 980323. Violation Noted:On 970908,WJ Ginn,Employee of Contractor to Entergy Operations,Inc,Deliberately Submitted Info to Licensee That Was Incomplete & Inaccurate
ML20217A44617 April 1998Notice of Violation from Insp on 980222-0404.Violation Noted:Established Measures Did Not Assure That Deviation from Environ Design Criteria Was Controlled
ML20217B47024 March 1998Notice of Violation from Insp on 980223-26.Violation Noted: Licensee Not Maintained Records of Reviews of Radiation Protection Program Content & Implementation
ML20248L89519 March 1998Notice of Violation from Insp on 980111-0221.Violation Noted:Petcock Valves for Listed Dampers Found Fully Closed, But Dampers Operated in Pneumatic Mode.Controls to Ensure Valves Correctly Positioned Inadequate
ML20202B9226 February 1998Notice of Violation from Insp on 971130-980110.Violation Noted:On 971204,extension Cord Was Draped Across safety-related Cable Tray 1TX817B w/free-air Cables & Required one-foot Separation Was Not MaintainedCondition Adverse to Quality
ML20202A7255 February 1998Notice of Violation from Insp on 971008-15.Violation Noted: on 971010,radiation Protection Technician Working in 95-ft Elevation of Fuel Storage Bldg Reached Into Posted Contaminated Area W/O Adhering to anti-contaminated Clothes
IR 07100012/201102924 December 1997Notice of Violation from Insp on 971012-1129.Violation Noted:On 971030,lower Primary Containment Air Lock Failed During Performance of TS SR 3.6.1.2.1,thus Rendering Air Lock Inoperable for Reasons Other than TS 3.6.1.2
ML20198A36723 December 1997Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violations Noted:On 970913,adequate Procedures Covering Operation of Shutdown Cooling Were Not MaintainedTime to boil
ML20199E18017 November 1997Notice of Violation from Insp on 970831-1011.Violation Noted:Gate to Radwaste 136-foot Elevation Drum Storage Area,An Area W/Radiation Levels of 1000 Mrem Per H of Greater,Was Found Unlocked & UnguardedHigh Radiation Area
ML20211E10426 September 1997Notice of Violation from Insp on 970720-0830.Violation Noted:On 970717,individuals Responsible to Perform Functions Failed to Close & Independently Verify Closed,Breaker EGS-ACB11 EDG Neutral Breaker as SpecifiedFire Protection Program
ML20197G71716 September 1997Notice of Violation from Insp on 970804.Violation Noted: in Sept 1996,KN Ross Employee of Contractor to NRC Licensee Submitted Inaccurate Info on Security Questionaire
ML20210T24910 September 1997Notice of Violation from Insp on 970804-08.Violation Noted: on 970806,inspectors Determined That Smear Samples Have Never Been Collected & Concentration of Radionuclides Determined for Dry Active Waste Stream
ML20217H5786 August 1997Notice of Violation from Insp on 970608-0719.Violation Noted:No Instructions or Procedures to Ensure That All Licensed Operators Were Required to Wear Corrective Eyewear as Condition of Individual Licenses
ML20149H14121 July 1997Partially Withheld Notice of Violation from Insp on 970623-27.Violation Noted:On 970626,inspector Identified That Video Capture Sys Did Not Have Capability of Generating Audible Alarm
ML20141E32326 June 1997Notice of Violation from Insp on 970427-0607.Violation Noted:Licensee Failed to Follow Procedure EIP-2-001,in That Licensee Entered TS Limiting Condition for Operation 3.4.5 Upon Determination & Did Not Declare Unusual EventPressure Boundary Leakage
Fire Protection Program
Fire Watch
Hourly Fire Watch
ML20141G57419 May 1997Notice of Violation from Insp on 970316-0426.Violation Noted:Three Examples Identified Where Procedures Were Not Adequately Maintained,Procedures Did Not Require Independent Verification of Activities Prescribed in ANSI 18.7-1976Temporary Modification
ML20137T49211 April 1997Notice of Violation from Insp on 970202-0315.Violation Noted:As of 970315,administrative Procedures Not Developed in Sufficient Scope to Implement Requirements of TS 5.2.2.eMissed surveillance
ML20135A46320 February 1997Notice of Violation from Insp on 961215-970201.Violation Noted:Activities Affecting Quality Were Not Accomplished IAW Instructions in That All Gaps in Floor Were Not Covered During Work to Preclude Dropping Intems in SSW
ML20133F1627 January 1997Notice of Violation from Insp on 961103-1214.Violation Noted:Procedure SOP-0040, Hydrogen Mixing,Purge,Recombiners & Igniters, Rev 9,was Not Properly Maintained
ML20135B5752 December 1996Notice of Violation from Insp on 960922-1102.Violation Noted:Listed Instances Where Written Procedures Not Properly Implemented
ML20134H1488 November 1996Notice of Violation from Insp on 960826-30 & 0909-13. Violation Noted:From 950331 Until 960912,design Basis for Operation of SSW CT Fans Was Not Correctly Translated Into ARP ARP-870-55, P870-55 Alarm Response
ML20134G4547 November 1996Notice of Violation from Insp on 960729-0827.Violations Noted:Licensee Failed to Perform SR 3.8.4.8 within 18 Month Required Frequency
ML20128N49011 October 1996Notice of Violation from Insp on 960506-21.Violation Noted: on 960214,while in Mode 1,instrument & Control Technicians Found Valve A4-B21*N094E Closed When Valve Should Have Been Open,Which Rendered Drywell Pressure Transmitter Inoperable
ML20128G7997 October 1996Notice of Violation from Insp on 960811-0921.Violation Noted:Procedure RSP-0203 Was Not Properly Implemented in That Individual Entered Radiologically Controlled Area W/Out Functional Direct Reading Dosimeter
ML20149F5548 August 1994Notice of Violation from Insp on Stated Date.Violation Noted:Maint Work Order E568208 Did Not Include Step for Installation of Jumper to Prevent Interruption of Power Supply Neutral Circuit
ML20059G99820 January 1994Notice of Violation from Insp on 931107-1218.Violation Noted:Maint That Affected Performance of safety-related Equipment Was Not Performed in Accordance W/Written ProceduresEnforcement Discretion
ML20059K4739 November 1993Notice of Violation from Insp on 930822-0925.Violation Noted:Mcr Radiation Monitoring Panel RM-11 safety-related Annuciators Did Not Have Alarm Response Procedure
ML20058J8439 November 1993Errata to Notice of Violation from Insp on 930822-0925, Reflecting Editorial Changes Made to Violations
ML20056G79331 August 1993Notice of Violation from Insp on 930726-30.Violation Noted: Four Zones Defeated During Testing of Protected Area Detection Sys
ML20056C96623 July 1993Notice of Violation from Insp on 930614-18.Violation Noted: Licensee Failed to Follow Commitment in TS in Performance of Reload Fuel Analysis for Cycle 5
ML20127C9898 January 1993Notice of Violation from Insp on 921108-1219.Violation Noted:On 921125,licensee Entered Specified Condition When LCO Not Met,In That Reactor Pressure Increased to Greater than 150 Psig W/Rcics Inoperable
ML20126G16028 December 1992Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $100,000.Noncompliance Noted:Licensee Did Not Make Adequate Surveys to Assure That Individauls Were Exposed to Airborne Concentrations Exceeding in 10CFR20.103High Radiation Area
ML20125D30210 December 1992Notice of Violation from Insp on 920927-1107.Violation Noted:Both Trains of Standby Gas Treatment Not Operable When Standby Gas Treatment Was in Containment Purge Mode
ML20127D41810 September 1992Notice of Violation from Insp on 920705-0815.Violation Noted:Licensee Testing of Safety Relief Valve Accumulator Check Valves Did Not Verify That Disk Traveled to Seat Promptly
ML20128P69215 April 1991Notice of Violation from Insp on 910225-26.Violation Noted:Inspectors Observed on 910225,insufficient Numbers of Trained Security Officers on Second Shift to Meet Contingency Plan & Procedural Commitments
ML20058P7499 August 1990Notice of Violation from Insp on 891023-27 & 1113-17. Violations Noted:Nuclear Licensing Failed to Take Actions Necessary to Assure Timely Response for 76 Examples of Regulatory Correspondence Classified Response RequiredCondition Adverse to Quality
ML20247B0751 September 1989Notice of Violation from Insp on 890701-31.Violation Noted: Failure to Implement Adequate Corrective Actions
ML20247R27528 July 1989Notice of Violation from Insp on 890601-30.Violation Noted: Administrative Procedure ADM-0028, Maint Work Order, Noted as Not Providing Specific Ref Steps If Valve Manipulations Performed or Sys Restored,Per Reg Guide 1.33
ML20247E76121 July 1989Notice of Violation from Insp on 890501-05 & 15-19. Violation Noted:Failure to Establish Test Program to Assure Operability of Fuel Bldg Ventilation Subsystem & Main Control Room Under Design Basis Conditions
ML20247K01117 July 1989Notice of Violation from Insp on 890605-09 & 19-23.Violation Noted:Facility Review Committee Did Not Review Activities Required by Tech Specs,Reviewed Only 12 Mod Requests of 19 Described in 1987-1988 Annual 10CFR50.59 Rept
ML20245L49730 June 1989Notice of Violation from Insp on 890501-31.Violations Noted: Corrective Maint Procedure for Freeze Seal Did Not Require Use of Temp Detecting Device in Sleeve of Freeze Seal Chamber to Monitor Integrity of Freeze Seal
ML20247Q98031 May 1989Notice of Violation from Insp on 890315-0430.Violations Noted:Adequate Corrective Actions Not Taken to Prevent Repeat Violations of Administrative Procedure ADM-027, Protective Tagging