 Issue dateTitleTopic
ML20024E21120 July 1983Ro:On 830622,24 & 0711,PAB & Electrical Tunnel & Control Room & Cable Spreading Room Determined to Be Nonfunctional Due to Voids & Cracks in Coating of Penetration Fire BarriersFire Barrier
Hourly Fire Watch
ML20052H18012 May 1982Telecopy of Ro:On 820415,surveillance Test 3PC-R4 Indicated That Pressure Transmitters PT456,PT457 & PT454 Were Out of Spec Nonconservatively.Cause Not Stated
ML20051P5326 May 1982RO 82-17:on 820505,air Conditioning Sys,Booster Fans for Filter Operation & Cooling Water Supply Declared Inoperable Due to Motor Failures.Also Reported Per Part 21
ML20050C27029 March 1982Telecopy Message of Ro:On 820327,small Leak Discovered on Shell Side of Steam Generator 32 W/Reactor in Cold Shutdown Constituting Abnormal Degradation in Primary Containment Boundary.Cause Not Stated.Investigation Continuing
ML20050A44725 March 1982Telecopy Version of Ro:On 820324,small Primary to Secondary Leak Developed in Steam Generator 33.Generator Removed from Svc & Unit Proceeding to Cold Shutdown.Total Release to Atmosphere Was Less than 0.5 Ci,W/No Iodine Released
ML20042A66411 March 1982Ro:Operating Procedures Will Be Revised to Require Operability of Safeguards Equipment Necessary to Mitigate Steamline Break Transient Prior to Heating RCS Above 350 F from Cold Shutdown
ML20042A5688 March 1982RO 82-009:on 820305,nitrogen Pressure in Boron Injection Tank Observed Below 90 Psig.Caused by Failure of Two Nitrogen Pressure Regulator Valves.Procedure Changed.Also Reported Per Part 21Boric Acid
ML20039A7629 December 1981Ro:On 811208,pint Per Minute Leak Observed in Cooling Coil in Number 34 Fan Cooler Unit Motor Cooler Inside Containment.Cause Not Stated.Approved Repairs Were Immediately Performed & Leak Was Stopped
ML20011A46729 September 1981Ro:On 810923,after Verifying Primary to Secondary Leakage in Number 31 Steam Generator Following RCS Hydro,Unit Proceeded from Hot Shutdown to Cold Shutdown.Verification of Calculation for Determining Leak Size Exceeded Tech Specs
ML20010G8318 September 1981Ro:On 810731,transformer 11EC4 Taken Out of Svc for Repair, Deactivating Bus Section 4 Which Feeds Motor Driven Fire Pump 12.On 810801,temporary Svc Restored to Fire Pump,But W/O Automatic Start.Transformer 11EC4 Back in Svc 810819
ML18085B16817 October 1980RO 80-054/01P-0:on 801016,fire Pump Failed to Start on Receipt of Automatic Signal.Situation Recurred Following Day.Cause of Failures Is Undetermined
ML09356081812 January 1977RO 76-2-28(A):on 761214,boric Acid Storage Tanks Had Concentrations in Excess of Upper Limit.Caused by Inaccuracies in Sampling Technique of Concentrates Makeup to Boric Acid Storage TanksBoric Acid