 Issue dateTitleTopic
ML20045D30118 June 1993Special Rept 93-002:on 930521,invalid Failure of Sdg 12 Occurred Due to False High Jacket Water Temp Signal, Generated by Faulty Jacket Water Temp Switch.Faulty Switch Replaced
ML20044H0762 June 1993Special Rept 93-001:on 930504,trip Signal Occurred During Performance of Monthly Functional Test for Standby DG 11. Caused by Inadequate Work Instructions.Surveillance Procedure Will Be Revised to Address Probe Magnetic Bars
ML20042G8718 May 1990Ro:On 900412,groundwater Level Reading Taken from Dewatering Well 8 Exceeded 109 Ft Mean Sea Level Design Basis.Caused by Incorrect Level Sensor Probe Setting.Probe Adjusted Using New Setpoint Data to Cycle Dewatering Well at 108.4 Ft
ML19354E68517 January 1990Special Rept 89-009-00:on 891218,diesel Generator 11 Failed. Potential Transformer Fuse Holders Found Loose.No Obvious Cause of Event Identified.Diesel Retested Satisfactorily W/O Recurrence of Original Incident
ML19325E35624 October 1989Special Rept 89-008-0:on 891010,instrument Channel Inoperable for More than 72 H.Caused by Turbine Bldg Exhaust Accident Range Monitor Declared Inoperable After Sample Flow Calculations Could Not Be Completed Due to Leaking ValveGrab sample
ML20024F47829 August 1983RO 83-072/0:on 830729,30 & 0814-16,control Room Air Temp Exceeded Tech Spec Limit.Caused by Lack of Operating Control Room HVAC Subsystems & Low Freon in Subsystem B, Respectively.No Corrective Action Stated
ML20024D04327 July 1983RO 83-059/0:on 830620,fire-rated Doors OC412 & OC712 to Reactor Protection Sys Motor Generator Set Rooms Blocked Open to Aid Room Ventilation.Fire Watch Established.Expected Restoration Date of Doors Is 830731Fire Watch
ML20024C33127 June 1983RO 83-052/0:on 830523,listed Fire Rated Penetrations Opened to Implement Design Change Packages.Hourly Fire Watches Established & Will Be Maintained Until Penetrations Resealed by 830801
ML20024C26127 June 1983Updated RO 83-027/1:on 830321,during Seismic Monitoring Sys Functional Test,Operation of Chart Recorders & Spectrum Analyzers Unacceptable.Caused by Faulty Circuit Card.Card Replaced.Sys Restored on 830519
ML20024C33224 June 1983RO 83-050/0:on 830519,floor Penetration CE-37G in Control Bldg Upper Cable Room Opened to Rework Cable Tray Hanger. Fire Watch Established Until Penetration Sealed on 830603. Seven-day Limiting Condition for Operation ExceededFire Watch
ML20024C27624 June 1983RO 83-049/0:on 830526,halon Bottle 2 in Panel P936 Discharged Until Empty.Hourly Fire Watch Established Pending Bottle Replacement.Limiting Condition for Operation to Be Maintained.Next Rept Will Be Submitted by 830731Hourly Fire Watch
ML20024C11522 June 1983RO 83-047/0:on 830508 & 11,fire Protection Halon Sys for Two Control Room Back Panels Failed Surveillances.Caused by Inability to Meet Tolerance Specified for Full Charge Pressure.Surveillance Procedure Revised
ML20023D5589 May 1983RO 83-029/0:on 830422,50-meter Wind Direction Reading Did Not Agree w/10-meter Reading.Caused by Incorrectly Wired New Sensors Located in Design Change Package 82-502.Wiring Diagram Corrected
ML20023B63828 April 1983RO 83-025/0:on 830322,fire Rated Penetrations Opened to Implement Design Change Packages.Hourly Fire Watches Established within 1 H & Will Be Maintained for Duration of Planned Maint Activities.Work to Be Completed by 830610
ML20023B50228 April 1983RO 83-026/0:on 830327,security Access Card Reader to Fire Door 1A318,Elevation 166 Ft,In Auxiliary Bldg Malfunctioned. Caused by Fire Door Blocked to Allow Personnel Access.Card Reader Reworked & Returned to Svc 830405Hourly Fire Watch
ML20028A53110 November 1982Ro:On 820813,Channel a Tripped & HPCS Initiated on False Low Level Signal.Caused by Failure to Follow Procedures.On 820814,HPCS Initiated by True Low Reactor Water Level Signal from B21-N073 L&R.Procedures Developed to Correct Problems