Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML23142A27322 May 2023Duke Fleet - Request for Additional Information Proposed Alternative for Steam Generator Welds in Accordance with 10 CFR 50.55a(z)(1)Incorporated by reference
RA-17-0039, Response to Request for Additional Information (RAI) Regarding 10 CFR 50.55a(z)(1)Proposed Alternative to ASME Section XI Threads in Flange Examination (17-GO-001)9 August 2017Response to Request for Additional Information (RAI) Regarding 10 CFR 50.55a(z)(1)Proposed Alternative to ASME Section XI Threads in Flange Examination (17-GO-001)Finite Element Analysis
Stress corrosion cracking
Weak link
RA-17-0016, Duke Energy - Proposed Alternative in Accordance with 10 CFR 50.55(z)(1) for Examination of ASME Section XI, Examination Category B-G-1, Item Number B6.40, Threads in Flange (17-GO-001)29 March 2017Duke Energy - Proposed Alternative in Accordance with 10 CFR 50.55(z)(1) for Examination of ASME Section XI, Examination Category B-G-1, Item Number B6.40, Threads in Flange (17-GO-001)Finite Element Analysis
Stress corrosion cracking
Weak link
BSEP 11-0011, Response to Request for Additional Information - Proposed Alternatives for the Third 10-Year Inservice Inspection Program28 January 2011Response to Request for Additional Information - Proposed Alternatives for the Third 10-Year Inservice Inspection Program
ML0617301291 June 2006NUREG-1856, Safety Evaluation Report Related to the License Renewal of the Brunswick Steam Electric Plant, Units 1 and 2, Section 3 - Aging Management Review Results Through EndSafe Shutdown
Boric Acid
High winds
Ultimate heat sink
Non-Destructive Examination
Fire Barrier
Anticipated operational occurrence
Hydrostatic
Coatings
Nondestructive Examination
VT-2
Incorporated by reference
Condition Adverse to Quality
Aging Management
Local Leak Rate Testing
Feedwater Heater
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Integrated leak rate test
Eddy Current Testing
Moisture barrier
License Renewal
Exemption Request
Commercial Grade
Maintenance Rule Program
Biofouling
EVT-1
Through-Wall Leak
Preliminary White Finding
Fire Protection Program
Dissimilar Metal Weld
Flow Induced Vibration
Power Uprate
Thermography
Thermal fatigue
ML05172062121 June 2005Audit and Review Report for Plant Aging Management Reviews and Programs, Brunswick Steam Electric Plant, Units 1 and 2Safe Shutdown
Ultimate heat sink
Non-Destructive Examination
Fire Barrier
Coatings
Nondestructive Examination
VT-2
Aging Management
Local Leak Rate Testing
Flow Accelerated Corrosion
Feedwater Heater
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Eddy Current Testing
Moisture barrier
License Renewal
Maintenance Rule Program
Biofouling
EVT-1
Through Wall Leak
Preliminary White Finding
Fire Protection Program
Dissimilar Metal Weld
Flow Induced Vibration
Power Uprate
ML20078Q22015 December 1994Rev 1 to Caculation CPL-34Q-301, Weld Overlay Repair Design for BSEP Unit 1 Feedwater Safe-End WeldsSafe Shutdown
Packing leak
High Radiation Area
Non-Destructive Examination
Weld Overlay
Hydrostatic
Coatings
Operating Basis Earthquake
Nondestructive Examination
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Code Reconciliation
Earthquake
Liquid penetrant
Fire Protection Program
Backfit
Unidentified leakage
ML0311405497 November 1991Withdrawn NRC Generic Letter 1991-018: Information to Licensees Regarding Two NRC Inspection Manual Sections on Resolution of Degraded and Nonconforming Conditions and on OperabilitySafe Shutdown
Unanalyzed Condition
Fitness for Duty
Probabilistic Risk Assessment
Condition Adverse to Quality
Missed surveillance
Operability Determination
Exemption Request
Pressure Boundary Leakage
Backfit
Operational leakage
ML20011E4715 February 1990Informs That IGSCC Insp Plans & Results Will Not Be Submitted for Next Refueling Outage for Unit 1 as Previously Committed in 890314 Ltr & That Evaluation & Repair Plans for Flaws Will Be Submitted to NRC Prior to Startup
ML20246J5539 May 1989Safety Evaluation Concluding That Plant Can Be Safely Operated for Another 18-month Fuel Cycle in Configuration Following Reload 5,per Improvements,Insps & Repairs to Plant IGSCCNon-Destructive Examination
Weld Overlay
Nondestructive Examination
Stress corrosion cracking
ML20246K36125 April 1989Rev 0,Vol 2 to Weld Overlay Repairs of Recirculation Inlet & Core Spray Nozzle-to-Safe End Welds & Recirculation Inlet Nozzle Thermal Sleeve Attachment Welds,Brunswick Steam Electric Plant,Unit 1Weld Overlay
Nondestructive Examination
ML20245D37625 April 1989Safety Evaluation Supporting Licensee IGSCC Program for Refuel 7 OutageNon-Destructive Examination
Weld Overlay
Nondestructive Examination
Finite Element Analysis
Intergranular Stress Corrosion Cracking
Liquid penetrant
Through Wall Leak
Unidentified leakage
ML20150E32921 March 1988Design Rept for Recirculation Sys Repairs Performed During 1988 Refueling Outage at Brunswick Steam Electric Plant Unit 2Weld Overlay
Finite Element Analysis
Intergranular Stress Corrosion Cracking