MONTHYEARRS-23-121, Sixth Ten-Year Interval Inservice Testing Program2023-11-30030 November 2023 Sixth Ten-Year Interval Inservice Testing Program RS-23-119, Supplemental Information Letter for Part 73 Exemption Request - Responses to Request for Confirmatory Information2023-11-10010 November 2023 Supplemental Information Letter for Part 73 Exemption Request - Responses to Request for Confirmatory Information RS-23-107, Relief Request I5R-22, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval2023-11-0808 November 2023 Relief Request I5R-22, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval RS-23-102, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-10-16016 October 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation RS-23-097, Constellation Energy Generation, LLC, Advisement of Leadership Changes and Submittal of Updated Standard Practice Procedures Plans2023-10-12012 October 2023 Constellation Energy Generation, LLC, Advisement of Leadership Changes and Submittal of Updated Standard Practice Procedures Plans RS-23-071, Application to Adopt TSTF-564, Safety Limit MCPR2023-08-30030 August 2023 Application to Adopt TSTF-564, Safety Limit MCPR RS-23-080, Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-264-A, Revision 0, 3.3.9 and 3.3.10 - Delete Flux Monitors Specific Overlap Requirement SRs2023-08-30030 August 2023 Constellation Energy Generation, LLC, Application to Revise Technical Specifications to Adopt TSTF-264-A, Revision 0, 3.3.9 and 3.3.10 - Delete Flux Monitors Specific Overlap Requirement SRs RS-23-077, Response to NRC Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations2023-06-16016 June 2023 Response to NRC Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations RS-23-078, Supplement to License Amendment Request to Revise Technical Specification 3.1.4, Control Rod Scram Times2023-06-16016 June 2023 Supplement to License Amendment Request to Revise Technical Specification 3.1.4, Control Rod Scram Times RS-23-042, Application to Revise Technical Specifications to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling2023-05-25025 May 2023 Application to Revise Technical Specifications to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling RS-23-070, Supplement to License Amendment Request Regarding Transition to GNF3 Fuel2023-05-16016 May 2023 Supplement to License Amendment Request Regarding Transition to GNF3 Fuel RS-23-057, Supplement to License Amendment Request Regarding Transition to GNF3 Fuel2023-04-17017 April 2023 Supplement to License Amendment Request Regarding Transition to GNF3 Fuel RS-23-049, Constellation Energy Generation, LLC, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-23023 March 2023 Constellation Energy Generation, LLC, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations RS-23-041, Response to Request for Additional Information for Alternative Request RV-23H2023-03-14014 March 2023 Response to Request for Additional Information for Alternative Request RV-23H RS-23-045, Constellation Energy Generation, LLC Submittal of Fitness for Duty Performance Data Reports for 2022 Per 10 CFR 26.717(c) & 10 CFR 26.2032023-02-28028 February 2023 Constellation Energy Generation, LLC Submittal of Fitness for Duty Performance Data Reports for 2022 Per 10 CFR 26.717(c) & 10 CFR 26.203 RS-23-003, Constellation Energy Generation, LLC, Summary of Changes to Quality Assurance Topical Report, NO-AA-10, and Decommissioning Quality Assurance Program, NO-DC-102023-01-31031 January 2023 Constellation Energy Generation, LLC, Summary of Changes to Quality Assurance Topical Report, NO-AA-10, and Decommissioning Quality Assurance Program, NO-DC-10 RS-23-004, Response to Request for Additional Information Regarding Transition to GNF3 Fuel License Amendment Request2023-01-23023 January 2023 Response to Request for Additional Information Regarding Transition to GNF3 Fuel License Amendment Request RS-22-126, Constellation Energy Generation, LLC - Request to Use Provisions of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI2022-11-30030 November 2022 Constellation Energy Generation, LLC - Request to Use Provisions of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI RS-22-121, Notice of Intent to Pursue Subsequent License Renewal Applications2022-11-0909 November 2022 Notice of Intent to Pursue Subsequent License Renewal Applications RS-22-117, Response to Request for Additional Information License Amendment Request Regarding New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies2022-11-0303 November 2022 Response to Request for Additional Information License Amendment Request Regarding New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies RS-22-116, Submittal of Relief Requests Associated with the Sixth Inservice Testing Interval2022-11-0101 November 2022 Submittal of Relief Requests Associated with the Sixth Inservice Testing Interval RS-22-115, Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors2022-10-19019 October 2022 Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors RS-22-092, Nine and Quad Cities - Application to Revise Primary Containment Isolation Instrumentation Technical Specifications in Accordance with TSTF-306, Revision 2, Add Action to LCO 3.3.6.1 to Give Option to Isolate the Penetration2022-10-0303 October 2022 Nine and Quad Cities - Application to Revise Primary Containment Isolation Instrumentation Technical Specifications in Accordance with TSTF-306, Revision 2, Add Action to LCO 3.3.6.1 to Give Option to Isolate the Penetration RS-22-066, License Amendment Request to Revise Technical Specification 3.1.4, Control Rod Scram Times2022-08-25025 August 2022 License Amendment Request to Revise Technical Specification 3.1.4, Control Rod Scram Times RS-22-065, License Amendment Request Regarding Transition to GNF3 Fuel2022-08-18018 August 2022 License Amendment Request Regarding Transition to GNF3 Fuel RS-22-093, Advisement of Leadership Changes for Constellation Energy Generation, LLC and Submittal of Updated Standard Practice Procedures Plans2022-08-18018 August 2022 Advisement of Leadership Changes for Constellation Energy Generation, LLC and Submittal of Updated Standard Practice Procedures Plans RS-22-101, Response to Request for Additional Information Related to Relief Request I6R-01 Associated with the Sixth Inservice Inspection Interval2022-08-10010 August 2022 Response to Request for Additional Information Related to Relief Request I6R-01 Associated with the Sixth Inservice Inspection Interval RS-22-099, Submittal of Upcoming Sixth Inservice Inspection Interval Relief Requests I6R-09 and I6R-102022-07-19019 July 2022 Submittal of Upcoming Sixth Inservice Inspection Interval Relief Requests I6R-09 and I6R-10 RS-22-082, Defueled Safety Analysis Report Update, Revision 112022-06-22022 June 2022 Defueled Safety Analysis Report Update, Revision 11 RS-22-080, Withdrawal and Proposed Alternative I6R-08 Associated with Code Case N-921 for Sixth Inservice Inspection Intervals2022-06-0909 June 2022 Withdrawal and Proposed Alternative I6R-08 Associated with Code Case N-921 for Sixth Inservice Inspection Intervals RS-22-064, License Amendment Request Regarding New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies with Proposed Change to Technical Specifications Section 4.3.12022-06-0808 June 2022 License Amendment Request Regarding New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies with Proposed Change to Technical Specifications Section 4.3.1 RS-22-051, Constellation Energy Generation, LLC - Update to Correspondence Addressees and Service Lists2022-04-12012 April 2022 Constellation Energy Generation, LLC - Update to Correspondence Addressees and Service Lists RS-22-049, Constellation Energy Generation, LLC, Supplemental Information to Correct Typographical Errors in Constellation'S Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for2022-04-0404 April 2022 Constellation Energy Generation, LLC, Supplemental Information to Correct Typographical Errors in Constellation'S Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for V RS-22-046, Relief Requests Associated with the Sixth Inservice Inspection Interval2022-03-25025 March 2022 Relief Requests Associated with the Sixth Inservice Inspection Interval RS-22-045, Constellation Energy Generation, LLC, Response to NRC Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations2022-03-25025 March 2022 Constellation Energy Generation, LLC, Response to NRC Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations RS-22-042, Report on Status of Decommissioning Funding for Shutdown Reactors2022-03-23023 March 2022 Report on Status of Decommissioning Funding for Shutdown Reactors RS-22-027, Constellation, Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated2022-02-23023 February 2022 Constellation, Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated P RS-22-023, Constellation Energy Generation, LLC, Executed Trust Fund Agreement Amendment and Subordinate Trust Agreement2022-02-23023 February 2022 Constellation Energy Generation, LLC, Executed Trust Fund Agreement Amendment and Subordinate Trust Agreement RS-22-019, Constellation Energy Generation, LLC - Update to Correspondence Addressees and Service Lists2022-02-16016 February 2022 Constellation Energy Generation, LLC - Update to Correspondence Addressees and Service Lists RS-22-015, Notification of Completion of License Transfer and Request to Continue Processing Pending NRC Actions Previously Requested by Exelon Generation Company, LLC2022-02-0101 February 2022 Notification of Completion of License Transfer and Request to Continue Processing Pending NRC Actions Previously Requested by Exelon Generation Company, LLC RS-21-009, Proposed Relief Request Associated with Code Case N-9212022-01-18018 January 2022 Proposed Relief Request Associated with Code Case N-921 RS-22-004, Supplement to Application to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements2022-01-0404 January 2022 Supplement to Application to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements RS-21-121, Proposed Changes to Decommissioning Trust Agreements and Master Terms2021-12-15015 December 2021 Proposed Changes to Decommissioning Trust Agreements and Master Terms RS-21-114, Request for Exemption from 10 CFR 2.109(b)2021-10-28028 October 2021 Request for Exemption from 10 CFR 2.109(b) RS-21-110, Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors2021-10-19019 October 2021 Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors RS-21-103, Updated Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations for Byron Station and Dresden Nuclear Power Station2021-09-28028 September 2021 Updated Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations for Byron Station and Dresden Nuclear Power Station RS-21-097, Withdrawal of Certification of Permanent Cessation of Power Operations for Dresden Nuclear Power Station, Units 2 and 3, and Previously Submitted Licensing Actions in Support of Decommissioning2021-09-15015 September 2021 Withdrawal of Certification of Permanent Cessation of Power Operations for Dresden Nuclear Power Station, Units 2 and 3, and Previously Submitted Licensing Actions in Support of Decommissioning RS-21-091, Implementation of Insider Threat Program Requirements Associated with the Voluntary Security Clearance Program and Advisement of Leadership Changes2021-09-13013 September 2021 Implementation of Insider Threat Program Requirements Associated with the Voluntary Security Clearance Program and Advisement of Leadership Changes RS-21-086, Supplement to Request for Exemptions from Portions of 10 CFR 50.47 and 10 CFR 50, Appendix E2021-08-23023 August 2021 Supplement to Request for Exemptions from Portions of 10 CFR 50.47 and 10 CFR 50, Appendix E RS-21-078, Response to Request for Additional Information for Application to Revise Technical Specification to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements, and TSTF-583-T, TSTF-582 Diesel2021-08-19019 August 2021 Response to Request for Additional Information for Application to Revise Technical Specification to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements, and TSTF-583-T, TSTF-582 Diesel 2023-08-30
[Table view] |
Text
Exelon Generation 4300 Winfield Road Warrenville. IL 60555 630 657 2000 Office RS-20-026 10 CFR 50 .54(f)
March 6 , 2020 ATTN : Document Control Desk U.S. Nuclear Regulatory Commission Washington , DC 20555 Dresden Nuclear Power Station , Units 2 and 3 Renewed Facility Operating License Nos. DPR-19 and DPR-25 NRC Docket Nos. 50-237 and 50-249
Subject:
Supplemental Information Related to Seismic Probabilistic Risk Assessment Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident
References:
- 1. Letter from E. J. Leeds (NRC) to all Licensees, "Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50 .54(f) Regarding Recommendations 2.1 , 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident,"
dated March 12, 2012(ML12053A340)
- 2. EPRI Report 1025287, "Seismic Evaluation Guidance: Screening , Prioritization and Implementation Details (SPID) for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," dated November 27 , 2012 (ML12333A170)
- 3. Letter from G . T. Kaegi (Exelon Generation Company , LLC (EGC)) to NRC , "Exelon Generation Company, LLC , Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites) , Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident," dated March 31 , 2014(ML14091A012)
- 4. Letter from T. Govan (NRC) to B. Hanson (EGC) , "Dresden Nuclear Power Station , Units 2 and 3 - Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(f), Seismic Hazard Reevaluations Relating to Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident (TAC Nos. MF3877 and MF3878) ," dated April 27, 2015(ML15097A519)
March 6, 2020 U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 Seismic Probabilistic Risk Assessment Page 2
- 5. Letter from W. M. Dean (NRC) to Power Reactor Licensees, "Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendation 2.1 'Seismic' of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident," dated October 27, 2015(ML15194A015)
- 6. Letter from P. R. Simpson (EGC) to NRC, "Request for Extension of Due Date for Seismic Probabilistic Risk Assessment Submittal," dated May 14, 2018(ML18134A224)
- 7. Letter from L. Lund (NRC) to B. C. Hanson (EGC), "Dresden Nuclear Power Station, Units 2 and 3 - Response to Request for Extension of Seismic Probabilistic Risk Assessment Submittal," dated September 17, 2018(ML18236A262)
- 8. Letter from P. R. Simpson (EGC) to NRC, "Seismic Probabilistic Risk Assessment Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident," dated October 30, 2019 (ML193048567)
On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued a request for information pursuant to 10CFR 50.54(f) associated with the recommendations of the Fukushima Near-Term Task Force (NTTF) (Reference 1). Enclosure 1 of Reference 1 requested each licensee to reevaluate the seismic hazards at their sites using present-day NRC requirements and guidance, and to identify actions taken or planned to address plant-specific vulnerabilities associated with the updated seismic hazards.
Reference 2 contains industry guidance developed by Electric Power Research Institute (EPRI) that provides the screening, prioritization and implementation details (SPID) for the resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic. The SPID (Reference 2) was used to compare the reevaluated seismic hazard to the design basis hazard. The Dresden Nuclear Power Station (DNPS), Units 2 and 3 reevaluated seismic hazard (Reference 3) concluded that the ground motion response spectrum (GMRS) exceeded the design basis seismic response spectrum in the 1 to 1O Hz range, and therefore a seismic probabilistic risk assessment was required.
Reference 4 contains the NRC Assessment of the DNPS, Units 2 and 3 seismic hazard submittal which concluded that the reevaluated seismic hazard prepared for DNPS, Units 2 and 3 is suitable for other activities associated with the NTTF Recommendation 2.1: Seismic.
Reference 5 provided the NRC final seismic hazard evaluation screening determination results and the associated schedules for submittal of the remaining seismic hazard evaluation activities for DNPS, Units 2 and 3. Reference 5 indicated that the DNPS, Units 2 and 3 Seismic Probabilistic Risk Assessment (SPRA) was expected to be submitted by June 30, 2019. In Reference 6, Exelon Generation Company, LLC requested an extension of the DNPS Units 2 and 3 SPRA submittal date to December 31 , 2019. This extension request was approved by the NRC in Reference 7.
March 6, 2020 U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 Seismic Probabilistic Risk Assessment Page 3 The enclosure to Reference 8 contained the DNPS, Units 2 and 3 SPRA Summary Report which provided the information requested in Enclosure 1, Item (8) B. of the 10 CFR 50.54(f) letter.
This letter corrects an issue identified in the review of information provided in Reference 8. The issue identified is related to a minor error that does not impact the results and conclusions within the Reference 8 submittal. This issue has been entered into the EGC Corrective Action Program under Issue Report No. 4319440, and an extent of condition review has determined that the issue is limited to the items discussed in the Attachment to this letter. No other text, results, or conclusions in the Reference 8 submittal are affected.
This letter contains no new regulatory commitments or revisions to existing regulatory commitments.
If you have any questions regarding this report, please contact Mitchel Mathews at (630) 657-2819.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 61h day of March 2020.
Patrick R. Simpson Sr. Manager Licensing Exelon Generation Company, LLC
Attachment:
Supplemental Information Related to Dresden Nuclear Power Station, Units 2 and 3 Seismic Probabilistic Risk Assessment in Response to 50.54(f) Letter with Regard to NTTF 2.1 Seismic, dated October 30, 2019 cc: Regional Administrator - NRC Region Ill NRC Senior Resident Inspector - Dresden Nuclear Power Station NRC Project Manager, NRR - Dresden Nuclear Power Station Mr. Milton Valentin-Olmeda, NRR/DLP/PBMB, NRC Illinois Emergency Management Agency- Division of Nuclear Safety
bee: Site Vice President - Dresden Nuclear Power Station Vice President - Licensing & Regulatory Affairs Corporate Licensing Director - West Site Engineering Director - Dresden Nuclear Power Station Director Org. Performance and Regulatory- Dresden Nuclear Power Station Site Operations Director - Dresden Nuclear Power Station Director Corporate Engineering - PRA Regulatory Assurance Manager - Dresden Nuclear Power Station Corporate Licensing Manager - West Licensing Records Commitment Tracking Coordinator- West Duane Avery - Dresden Nuclear Power Station John A. Feigl - Dresden Nuclear Power Station Eyad Ali - Dresden Nuclear Power Station Reha Alkan - Dresden Nuclear Power Station Philip J. Tarpinian , Jr. - Corporate Kennett Square Danny Brush - Corporate Cantera
Attachment Supplemental Information Related to Dresden Nuclear Power Station, Units 2 and 3 Seismic Probabilistic Risk Assessment in Response to 50.54(f) Letter with Regard to NTTF 2.1 Seismic, dated October 30, 2019
ATTACHMENT Supplemental Information Related to Dresden Nuclear Power Station, Units 2 and 3 Seismic Probabilistic Risk Assessment in Response to 50.54(f) Letter with Regard to NTTF 2.1 Seismic, dated October 30, 2019 During the development of the response to an NRC request for information related to the Dresden Nuclear Power Station (DNPS) , Units 2 and 3 Seismic Probabilistic Risk Analysis (SPRA) submittal dated October 30, 2019, Exelon Generation Company, LLC (EGC) found that the conditional large early release probability (CLERP) values presented in Table 7c-1 of the submittal for Sensitivity Case 7c are slightly inaccurate. The CLERP results only are slightly inaccurate because the DNPS Plant Availability (i.e., criticality) factor was mistakenly incorporated twice (instead of the intended once) in the calculation of the CLERPs.
Since the DNPS Plant Availability factor used in the DNPS SPRA (i.e., from the DNPS Internal Events PRA) is very close to 1.0 (i.e., 0.965 reactor critical year/calendar year) the double counting of this factor in the CLERP in Table 7c-1 has a very minor impact and does not change the conclusions of Sensitivity Case 7c. This same issue exists in the DNPS SPRA Quantification (QU) Notebook (NB) , DR-PRA-020.006, Rev. 0, App. I, Table 7c-1 that was prepared by EGC. Revision 1 of DR-PRA-020.006 has been issued to address this issue. The DNPS SPRA base case results and all other sensitivity case results, especially Seismic Core Damage Frequency (SCDF) and Seismic Large Early Release Frequency (SLERF) values reported in the October 30, 2019, Submittal and the Risk Management SPRA OU NB are unaffected. Moreover, the minor error does not impact the results and conclusions within the DNPS SPRA Submittal.
This minor error for Sensitivity Case 7c was determined to exist only in that specific sensitivity case table in the CLERP column of Table 7c-1. The Conditional Core Damage Probability and Conditional Large Early Release Probability values presented in Figure 5.4-3, Table 5.7-2, Figure 5.5-3 and Table 5. 7-3 of the DNPS SPRA submittal were reviewed and confirmed that they are all calculated correctly. Only the CLERP values in Table 7c-1 of the October 30, 2019, DNPS SPRA submittal and the associated table in the DNPS SPRA OU NB had the issue in question.
A revised version of Table 7c-1 is included below. This version is intended to supersede the Table 7c-1 that was provided in the DNPS SPRA submittal of October 30, 2019, in its entirety.
Part of the sensitivity case discussion that references the CLERP has also been updated to reflect that the CLERP at 1.5g ground motion is close to 1.0 instead of equal to 1.0. The updated discussion is shown below, preceding the updated Table 7c-1.
Page 1 of 2
ATTACHMENT Supplemental Information Related to Dresden Nuclear Power Station, Units 2 and 3 Seismic Probabilistic Risk Assessment in Response to 50.54(f) Letter with Regard to NTTF 2.1 Seismic, dated October 30, 2019 Additionally , this sensitivity shows that CLERP is close to 1.0 near ground motions of 1.5g . The table below shows the base frequencies and CLERPs compared to the sensitivity CLERPs for the extended G8 intervals.
Table 7c-1: Sensitivity Case to Extend the G8 Hazard Interval [52]
Extended GS Hazard SLERF In itiator Frequency Interval Range (g) (/yr) (/yr)l1l CLE RP 1.0to 1.1 1.78E-07 2.18E-07 8.45E-01 1.1to1 .2 1.37E-07 1.60E-07 8.90E-01 1.2to1.3 1.05E-07 1.18E-07 9.23E-01 1.3to1.4 7.98E-08 8.74E-08 9.46E-01 1.4to1.5 6.06E-08 6.54E-08 9.61 E-01 1.5+ 2.77E-07 2.93E-07 9.78E-01 Total 8.37E-07 9.41E-07 N/A (1) Interval frequency shown in this table is in units of /crit-yr and does not include the 0.965 criticality factor.
Page 2 of 2