Response to NuScale Topical Report Audit Question Question Number: A-NonLOCA.LTR-6 Receipt Date: 07/24/2023 Question:
While reviewing (( 2(a),(c) the NRC staff noticed (( }} 2(a),(c) the NRELAP Version 1.6 Theory Manual (Revision 10) may have an error and appears to be inconsistent (( }} 2(a),(c) The staff can support a clarification call to discuss (( }} 2(a),(c)
Response
Reference 29 of the Non-LOCA topical report, TR-0516-49416-P, Revision 4, is for the NRELAP5 Version 1.6 Theory Manual (SwUM-0304-17023, Revision 10). ((
}}2(a),(c)
NuScale Nonproprietary NuScale Nonproprietary
(( }}2(a),(c) No changes to the non-LOCA topical report or SDAA FSAR are required. The inconsistency in the NRELAP5 theory manual has been entered into the NuScale Corrective Action Program (CAP). The revision of the NRELAP5 theory manual to correct the inconsistency will be performed under the NuScale CAP. No changes to the SDAA are necessary. NuScale Nonproprietary NuScale Nonproprietary}}