Emergency Preparedness Biennial Exercise Inspection Report 05000336/2024501 and 05000423/2024501
ML24183A242
Person / Time
Site: Millstone  
(DPR-065, NPF-049)
Issue date: 07/01/2024
From: Daniel Schroeder
Decommissioning, ISFSI, and Reactor Health Physics Branch
To: Carr E
Dominion Energy
References
IR 2024501
Download: ML24183A242 (1)


Text

July 1, 2024

SUBJECT:

MILLSTONE POWER STATION, UNITS 2 AND 3 - EMERGENCY PREPAREDNESS BIENNIAL EXERCISE INSPECTION REPORT 05000336/2024501 AND 05000423/2024501

Dear Eric Carr:

On June 6, 2024, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Millstone Power Station, Units 2 and 3 and discussed the results of this inspection with Michael O'Connor, Site Vice President, and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Daniel L. Schroeder, Chief Security, Emergency Preparedness, and Incident Response Branch Division of Radiological Safety and Security

Docket Nos. 05000336 and 05000423 License Nos. DPR-65 and NPF-49

Enclosure:

As stated

DANIEL SCHROEDER Digitally signed by DANIEL SCHROEDER Date: 2024.07.01 14:54:03 -04'00'

ML24183A242 X

SUNSI Review

X Non-Sensitive Sensitive

X Publicly Available

Non-Publicly Available

OFFICE RI/DRSS RI/DORS RI/DRSS

NAME JDeBoer MYoung DSchroeder

DATE 6/17/2024 6/24/2024 6/18/2024

Enclosure

U.S. NUCLEAR REGULATORY COMMISSION

Inspection Report

Docket Numbers:

05000336 and 05000423

License Numbers:

DPR-65 and NPF-49

Report Numbers:

05000336/2024501 and 05000423/2024501

Enterprise Identifier: I-2024-501-0003

Licensee:

Dominion Energy Nuclear Connecticut, Inc.

Facility:

Millstone Power Station, Units 2 and 3

Location:

Waterford, CT

Inspection Dates:

June 3, 2024 to June 6, 2024

Inspectors:

J. DeBoer, Senior Emergency Preparedness Inspector

J. Ambrosini, Nuclear Engineer

K. Hussar, Senior Physical Security Inspector

J. Kepley, Operations Engineer

S. Mercurio, Emergency Preparedness Inspector

Approved By:

Daniel L. Schroeder, Chief

Security, Emergency Preparedness and Incident Response Branch

Division of Radiological Safety and Security

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an emergency preparedness biennial exercise inspection at Millstone Power Station, Units 2 and 3, in accordance with the Reactor Oversight Process.

The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71114.04 - Emergency Action Level and Emergency Plan Changes

Inspection Review (IP Section 02.01-02.03) (1 Sample)

(1) The inspectors evaluated the following submitted Emergency Action Level and Emergency Plan changes:
  • MP-23-10-0, Change ERO DEENS (Dominion Energy Emergency Notification System) testing frequency from monthly to quarterly
  • MP-23-21-0, Replace Dose Assessment Procedure MP-26-EPI-FAP10 with EP-AA-DOS-101
  • MP-24-08-0, Revision to MP-26-EPI-FAP06-002 U2 EALS and MP-26-EPA-REF02 U2 EAL Basis Document
  • MP-24-09-0 Revision to MP-26-EPI-FAP06-003 U3 EALS and MP-26-EPA-REF03 U3 EAL Basis Document

This evaluation does not constitute NRC approval.

71114.07 - Exercise Evaluation - Hostile Action (HA) Event

Inspection Review (IP Section 02.01 - 02.11) (1 Sample)

(1) The inspectors evaluated the biennial emergency plan exercise. The exercise scenario simulated a loss of offsite power, a hostile action based event with imminent loss of physical control of the plant, and a steam generator tube rupture resulting in a radiological release requiring offsite response on June 4, 2024.

71114.08 - Exercise Evaluation - Scenario Review

Inspection Review (IP Section 02.01 - 02.04) (1 Sample)

(1) The inspectors reviewed and evaluated the proposed scenario for the biennial emergency plan exercise on May 8,

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification

The inspectors verified licensee performance indicators submittals listed below:

EP01: Drill/Exercise Performance (DEP) Sample (IP Section 02.12)===

(1) For the period April 1, 2023 - March 31, 2024

EP02: Emergency Response Organization (ERO) Drill Participation (IP Section 02.13) (1 Sample)

(1) For the period April 1, 2023 - March 31, 2024

EP03: Alert And Notification System (ANS) Reliability Sample (IP Section 02.14) (1 Sample)

(1) For the period April 1, 2023 - March 31,

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On June 6, 2024, the inspectors presented the emergency preparedness biennial exercise inspection results to Michael O'Connor, Site Vice President, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71114.07

Miscellaneous

MJUN24BE

Millstone Unit 2 NRC/FEMA HAB Exercise Package

Scenario

04/01/2024

MP-26-EPI-

FAP06-002

Millstone Power Station Unit 2 EAL Matrix

Revision 16

MP-PROC-EP-

MP-26-EPI-EPMP

Millstone Power Station Emergency Plan

Revision 67

71151

Corrective Action

Documents

Resulting from

Inspection

CR1261293

06/06/2024

Procedures

EP-AA-103

Emergency Preparedness Performance Indicators

Revision 11