Letter Sequence Other |
|---|
EPID:L-2024-TOP-0015, EPRI - LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation (Approved, Closed) EPID:L-2024-TOP-0016, (Open) EPID:L-2024-TOP-0018, (Open) |
Results
Other: ML24170A813, ML24170A891, ML24170A896, ML25014A290, ML25014A311, ML25080A217, ML25080A219, ML25080A320, ML25080A326, ML25080A327, ML25105A283, ML25105A284
|
MONTHYEARML24121A2092024-04-26026 April 2024 Request for Exemption of NRC Review Fees for Electric Power Research Institute (EPRI) - Analysis of PWR LOCA-Induced Fuel Fragmentation Relocation and Dispersal (FFRD) for Fuel Operating to Extended Burnup: Alternative Licensing Strategy Project stage: Request ML24121A2042024-04-26026 April 2024 Request for NRC Review of Epri’S Alternative Licensing Strategy (Als), Described Herein, Which Addresses PWR LOCA-Induced Fuel Fragmentation, Relocation, and Dispersal Project stage: Request ML24121A2082024-04-30030 April 2024 EPRI - LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation Project stage: Request ML24170A8962024-06-24024 June 2024 NRC Form 897, Topical Report Withholding Determination, for EPRI Technical Report Report 3002028674 LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants (L-2024-TOP-0015) Project stage: Other ML24170A9022024-06-24024 June 2024 NRC Form 898, Topical Report Completeness Determination, for EPRI Technical Report 3002023895 Materials Reliability Program: Xlpr Estimation of PWR Loss-of-Coolant Accident Frequencies (MRP-480) Project stage: Other ML24170A8912024-06-25025 June 2024 NRC Form 898, Topical Report Completeness Determination, for EPRI Technical Report 3002028674/5, LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants Project stage: Other ML24170A8132024-06-25025 June 2024 Acceptance and Withholding Determination for EPRI Alternative Licensing Strategy Which Addresses PWR LOCA-Induced Fuel Fragmentation, Relocation, and Dispersal Project stage: Other ML24170A8572024-06-25025 June 2024 NRC Form 898, Topical Report Completeness Determination, for EPRI Topical Report 3002028673, Loss-of-Coolant-Accident-Induced Fuel Fragmentation, Relocation and Dispersal with Leak-Before-Break Credit Project stage: Other ML24225A1352024-08-27027 August 2024 Revision of Dates for Review of Electric Power Research Alternative Licensing Strategy Topical Reports Project stage: Approval ML24318C2522024-11-21021 November 2024 E Mail Issuance of Plan for EPRI Regulatory Audit of Technical Report 3002028675 Np 3002028674 P LOCA Analysis of FFRD for Westinghouse 2, 3, and 4 Loop Plant EPID L 2024 NTR0003 Project stage: Approval ML25014A3112025-02-0303 February 2025 Nonprop - Revised Audit Plan for EPRI Report 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for Westinghouse 2-Loop, 3-Loop & 4-Loop Plants, Eval of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Frag, Rev 0 Project stage: Other ML25014A2902025-02-0303 February 2025 E-mail - Revised Audit Plan for EPRI Report 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for Westinghouse 2-Loop, 3-Loop & 4-Loop Plants, Eval of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Frag, Rev 0 Project stage: Other ML25049A0442025-02-26026 February 2025 Nonproprietary - Final RAIs for EPRI Report 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for W 2-Loop, 3-Loop and 4-Loop Plants - Proprietary, Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation, Project stage: RAI ML25055A1142025-02-26026 February 2025 E-Mail - Issuance of Report for Electric Power Research Institute Regulatory Audit in Support of Review of Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 Project stage: Approval ML25055A1172025-02-26026 February 2025 Nonproprietary - Report for Electric Power Research Institute Regulatory Audit in Support of Review of Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 Project stage: Approval ML25049A0432025-02-26026 February 2025 E-Mail-FINAL RAIs for EPRI Report 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for W 2-Loop, 3-Loop and 4-Loop Plants-Proprietary, Eval of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation, Rev. 0 Project stage: RAI ML25080A2192025-03-21021 March 2025 Nonproprietary - Final RAI-EPRI Rpt 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for W 2-, 3-, 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation - Rev. 0 Project stage: Other ML25080A2172025-03-21021 March 2025 Email - Final RAI-EPRI Rpt 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for W 2-, 3-, 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation - Rev. 0 Project stage: Other ML25080A3262025-03-21021 March 2025 EPRI Email Pointing Out the Change to 60 Days Project stage: Other ML25080A3202025-03-21021 March 2025 NRC Email Documenting the Change from 60 to 90 Days Project stage: Other ML25080A3272025-03-21021 March 2025 NRC Email Acknowledging the Change and Stating Path Forward Project stage: Other ML25107A0702025-04-22022 April 2025 E-Mail - Regulatory Audit in Support of NRC Staff’S Review of EPRI Report 3002028673, LOCA-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB) Credit - Alternative Licensing Strategy (Als) Project stage: Approval ML25107A0762025-04-22022 April 2025 Regulatory Audit Plan in Support of the Review Technical Report 3002028673, Rev 0, LOCA-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB) Credit - Alternative Licensing Strategy (Als) Project stage: Other ML25105A2842025-04-29029 April 2025 Enclosure 1: LOCA Analysis of FFRD for Westinghouse 2-Loop, 3-Loop and 4-Loop Plants Audit Report Nonproprietary (1) Project stage: Other ML25105A2832025-04-29029 April 2025 LOCA Analysis of FFRD for Westinghouse 2-Loop, 3-Loop and 4-Loop Plants Audit Report Cover Letter Project stage: Other ML25212A2492025-07-31031 July 2025 Final RAIs - EPRI Report 3002028673, LOCA-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB) Credit - Alternative Licensing Strategy (Als) Project stage: RAI ML25212A2462025-07-31031 July 2025 E-Mail - Final RAI - EPRI 3002028673, LOCA-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB) Credit - Alternative Licensing Strategy (Als) Project stage: RAI ML26029A4552026-02-0202 February 2026 Email - Issuance of Safety Evaluation for EPRI Technical Report 3002023895, Materials Reliability Program: Xlpr Estimation of PWR Loss-of-Coolant Accident Frequencies (MRP-480) Project stage: Approval ML26033A4732026-02-0606 February 2026 E-Mail - Issuance of Regulatory Audit Report for EPRI Technical Report 3002028673, Loss-of-Coolant-Accident-Induced Fuel Fragmentation, Relocation and Dispersal with Leak-Before-Break Credit - Alternative Licensing Strategy Project stage: Approval ML26033A4752026-02-0606 February 2026 Regulatory Audit Report for EPRI Technical Report 3002028673, Loss-of-Coolant-Accident-Induced Fuel Fragmentation, Relocation and Dispersal with Leak-Before-Break Credit - Alternative Licensing Strategy Project stage: Other ML26030A0292026-02-0909 February 2026 E-mail - Issuance of Safety Evaluation for EPRI Technical Report 3002028674/5, LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants, for Proprietary Review Project stage: Approval 2025-02-03
[Table View] |
Text
June 25, 2024 Aylin Kucuk Program Manager, Nuclear Fuels Electric Power Research Institute 3420 Hillview Avenue Palo Alto, CA 94304-1338
SUBJECT:
ACCEPTANCE AND WITHHOLDING DETERMINATION FOR ELECTRIC POWER RESEARCH ALTERNATIVE LICENSING STRATEGY WHICH ADDRESSES PRESSURIZED WATER REACTOR LOSS-OF-COOLANT-ACCIDENT-INDUCED FUEL FRAGMENTATION, RELOCATION, AND DISPERSAL (EPID NOS. L-2024-TOP-0015, L-2024-TOP-0016, AND L-2024-TOP-0018)
Dear Aylin Kucuk:
By letter dated April 26, 2024 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML24121A203), Electric Power Research Institute (EPRI) submitted the following reports to the U.S. Nuclear Regulatory Commission (NRC) for review and approval:
(1) EPRI Report 3002028673, Loss-of-Coolant-Accident (LOCA)-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB)
Credit - Alternative Licensing Strategy (ALS)
(2) EPRI Report 3002028675 (NP)/3002028674 (P), LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop and 4-Loop Plants - Proprietary, Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation (3) EPRI Report 3002023895, Materials Reliability Program: xLPR Estimation of PWR
[Pressurized Water Reactor] Loss-of-Coolant Accident Frequencies (MRP-480),
Collectively these three topical reports (TRs) are referred to as ALS for LOCA Analysis of FFRD. The ALS for LOCA Analysis for FFRD purports to demonstrate acceptable performance for LOCA-Induced FFRD phenomena in high burnup PWR fuel.
The purpose of this letter is to provide the results of the NRC staffs acceptance review of this request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review.
The NRC staff has found that the material presented in the package is sufficient to begin the review.
As noted above, the ALS for LOCA Analysis of FFRD consists of three TRs submitted by EPRI under the same package. The overarching TR is EPRI Report 3002028673 which is supported by EPRI Report 3002028675(NP)/3002028674(P) and MRP-480.
A. Kucuk An additional support TR, WCAP-18850-P/NP, Revision 0, Adaptation of the FULL SPECTRUM' LOCA (FSLOCA') Evaluation Methodology to Perform Analysis of Cladding Rupture for High Burnup Fuel, was submitted by Westinghouse Electric Company on February 29, 2024 (ADAMS Package Accession No. ML24060A160) and accepted for review by the NRC staff on May 9, 2024 (ADAMS Accession No. ML24123A057). All four of these TRs are being reviewed separately based on the technical topics. Also, each of the four TRs will have its own schedule, safety evaluation (SE), and fee exemption determination.
EPRI Report MRP-480 Report 3002028674/5 Report 3002028673 Audit Dates November/
December 2024 December 2024/
January 2025 January/
February 2025 Request for Additional Information (RAIs)
Issuance January 10, 2025 February 12, 2025 March 22, 2025 Draft SE Issuance October 17, 2025 December 12, 2025 February 17, 2026 Review Hours 1500 1500 1500 ADAMS Accession No. for TR Completeness Determination Form ML24170A902 ML24170A891 ML24170A857 Following issuance of the draft SE for vendor review and prior to issuance of the final SE, the NRC staff anticipates that the Advisory Committee for Reactor Safeguards (ACRS) will hold subcommittee and full committee meetings to review these TRs.
Although the NRC staff determined that the TRs contain sufficient technical information in both scope and depth to conduct a detailed technical review, there are other regulatory activities that may impact the TR review schedule. For example, the NRC staff noted the generic applicability of the methodology appears to depend upon the establishment of an alternative regulatory interpretation concerning the postulation of piping ruptures and the consideration of associated dynamic effects. While there is ongoing rulemaking activity to address fuel dispersal as part of the increased enrichment rulemaking, uncertainty exists on the exact nature of the rule that this TR would be used to demonstrate compliance with and any associated impacts of the rulemaking effort.
The level of effort could change once the NRC staff delves into matters of technical and policy matters during the detailed safety review of the TRs. Similarly, the schedule could change if additional rounds of RAIs are needed. If there are emergent complexities or challenges in our review that would cause changes to the initial forecasted completion date or significant changes in the forecasted hours, the reasons for the changes, along with the new estimates, will be communicated during the routine interactions with the assigned project manager.
By letter dated April 26, 2024, EPRI submitted a fee exemption request to the NRC Chief Financial Officer (ADAMS Accession No. ML24121A209). The response and decision for the fee exemption request will be communicated in a separate letter from the NRCs Office of the Chief Financial Officer.
A. Kucuk Finally, in the April 26, 2024, submittal, EPRI submitted a proprietary version (EPRI Report 3002028674) of report entitled LOCA Analysis of Fuel FFRD for Westinghouse 2-Loop, 3-Loop and 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation, along with a request under Title 10 the Code of Federal Regulation Paragraph 2.390, Public inspections, exemptions, requests for withholding, that proprietary information be withheld from public disclosure. As required by regulations, EPRI also submitted a non-proprietary or public version of the report EPRI Report 3002028675 which can be found in ADAMS at Accession No. ML24121A208. The NRC has completed its withholding determination and enclosed NRC Form 897, Topical Report Withholding Determination.
If you have questions regarding this matter, please contact Lois James via email at Lois.James@nrc.gov or James Delosreyes via email at James.Delosreyes@nrc.gov.
Sincerely,
/RA/
Gerond A. George, Branch Chief Licensing Project Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
Enclosures:
- 1. Form 898, Completeness Determination of EPRI Report 3002028673
- 2. Form 898, Completeness Determination of EPRI Report 3002028674/5
- 3. Form 898, Completeness Determination of EPRI Report MRP-480
- 4. Form 897, Withholding Determination of EPRI Report 3002028674/5 Docket No: 99902021
ML24170A812 (Pkg)
ML24170A813 (letter)
ML24170A857 (Form 898 for 3002028673)
ML24170A891 (Form 898 for 3002028674/5)
ML24170A902 (Form 898 for MRP-480)
ML24170A896 (Form 897 for 3002028674) ^via eConcurrence *via email NRR-004 OFFICE NRR/DORL/LLPB/PM^
NRR/DORL/LLPB/PM^
NRR/DORL/LLPB/LA^
NRR/DNRL/NVIB/BC*
NAME DMurray JDelosreyes DHarrison ABuford DATE 06/20/2024 06/20/2024 06/20/2024 06/21/2024 OFFICE NRR/DSS/SFNB/BC^
NRR/DORL/LLPB/BC^
NRR/DORL/LLPB/SPM^
NAME SKrepel GGeorge LJames DATE 06/24/2024 06/25/2024 06/25/2024