Letter Sequence Approval |
|---|
EPID:L-2024-NTR-0002, (Open) EPID:L-2024-NTR-0003, EPRI - LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation (Approved, Closed) EPID:L-2024-NTR-0004, (Open) EPID:L-2024-TOP-0015, EPRI - LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation (Approved, Closed) EPID:L-2024-TOP-0016, (Open) EPID:L-2024-TOP-0018, (Open) |
|
MONTHYEARML24121A2092024-04-26026 April 2024 Request for Exemption of NRC Review Fees for Electric Power Research Institute (EPRI) - Analysis of PWR LOCA-Induced Fuel Fragmentation Relocation and Dispersal (FFRD) for Fuel Operating to Extended Burnup: Alternative Licensing Strategy Project stage: Request ML24121A2082024-04-30030 April 2024 EPRI - LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation Project stage: Request ML24170A9022024-06-24024 June 2024 NRC Form 898, Topical Report Completeness Determination, for EPRI Technical Report 3002023895 Materials Reliability Program: Xlpr Estimation of PWR Loss-of-Coolant Accident Frequencies (MRP-480) Project stage: Other ML24170A8962024-06-24024 June 2024 NRC Form 897, Topical Report Withholding Determination, for EPRI Technical Report Report 3002028674 LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants (L-2024-TOP-0015) Project stage: Other ML24170A8572024-06-25025 June 2024 NRC Form 898, Topical Report Completeness Determination, for EPRI Topical Report 3002028673, Loss-of-Coolant-Accident-Induced Fuel Fragmentation, Relocation and Dispersal with Leak-Before-Break Credit Project stage: Other ML24170A8132024-06-25025 June 2024 Acceptance and Withholding Determination for EPRI Alternative Licensing Strategy Which Addresses PWR LOCA-Induced Fuel Fragmentation, Relocation, and Dispersal Project stage: Other ML24170A8912024-06-25025 June 2024 NRC Form 898, Topical Report Completeness Determination, for EPRI Technical Report 3002028674/5, LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants Project stage: Other ML24225A1352024-08-27027 August 2024 Revision of Dates for Review of Electric Power Research Alternative Licensing Strategy Topical Reports Project stage: Approval ML24318C2522024-11-21021 November 2024 E Mail Issuance of Plan for EPRI Regulatory Audit of Technical Report 3002028675 Np 3002028674 P LOCA Analysis of FFRD for Westinghouse 2, 3, and 4 Loop Plant EPID L 2024 NTR0003 Project stage: Approval ML25014A3112025-02-0303 February 2025 Nonprop - Revised Audit Plan for EPRI Report 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for Westinghouse 2-Loop, 3-Loop & 4-Loop Plants, Eval of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Frag, Rev 0 Project stage: Other ML25014A2902025-02-0303 February 2025 E-mail - Revised Audit Plan for EPRI Report 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for Westinghouse 2-Loop, 3-Loop & 4-Loop Plants, Eval of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Frag, Rev 0 Project stage: Other ML25055A1172025-02-26026 February 2025 Nonproprietary - Report for Electric Power Research Institute Regulatory Audit in Support of Review of Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 Project stage: Approval ML25049A0442025-02-26026 February 2025 Nonproprietary - Final RAIs for EPRI Report 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for W 2-Loop, 3-Loop and 4-Loop Plants - Proprietary, Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation, Project stage: RAI ML25055A1142025-02-26026 February 2025 E-Mail - Issuance of Report for Electric Power Research Institute Regulatory Audit in Support of Review of Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 Project stage: Approval ML25049A0432025-02-26026 February 2025 E-Mail-FINAL RAIs for EPRI Report 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for W 2-Loop, 3-Loop and 4-Loop Plants-Proprietary, Eval of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation, Rev. 0 Project stage: RAI ML25080A3272025-03-21021 March 2025 NRC Email Acknowledging the Change and Stating Path Forward Project stage: Other ML25080A3262025-03-21021 March 2025 EPRI Email Pointing Out the Change to 60 Days Project stage: Other ML25080A3202025-03-21021 March 2025 NRC Email Documenting the Change from 60 to 90 Days Project stage: Other ML25080A2172025-03-21021 March 2025 Email - Final RAI-EPRI Rpt 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for W 2-, 3-, 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation - Rev. 0 Project stage: Other ML25080A2192025-03-21021 March 2025 Nonproprietary - Final RAI-EPRI Rpt 3002028675(NP)/3002028674(P), LOCA Analysis of FFRD for W 2-, 3-, 4-Loop Plants - Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation - Rev. 0 Project stage: Other ML25107A0762025-04-22022 April 2025 Regulatory Audit Plan in Support of the Review Technical Report 3002028673, Rev 0, LOCA-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB) Credit - Alternative Licensing Strategy (Als) Project stage: Other ML25107A0702025-04-22022 April 2025 E-Mail - Regulatory Audit in Support of NRC Staff’S Review of EPRI Report 3002028673, LOCA-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB) Credit - Alternative Licensing Strategy (Als) Project stage: Approval ML25105A2832025-04-29029 April 2025 LOCA Analysis of FFRD for Westinghouse 2-Loop, 3-Loop and 4-Loop Plants Audit Report Cover Letter Project stage: Other ML25105A2842025-04-29029 April 2025 Enclosure 1: LOCA Analysis of FFRD for Westinghouse 2-Loop, 3-Loop and 4-Loop Plants Audit Report Nonproprietary (1) Project stage: Other ML25212A2462025-07-31031 July 2025 E-Mail - Final RAI - EPRI 3002028673, LOCA-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB) Credit - Alternative Licensing Strategy (Als) Project stage: RAI ML25212A2492025-07-31031 July 2025 Final RAIs - EPRI Report 3002028673, LOCA-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB) Credit - Alternative Licensing Strategy (Als) Project stage: RAI ML26029A4552026-02-0202 February 2026 Email - Issuance of Safety Evaluation for EPRI Technical Report 3002023895, Materials Reliability Program: Xlpr Estimation of PWR Loss-of-Coolant Accident Frequencies (MRP-480) Project stage: Approval ML26033A4752026-02-0606 February 2026 Regulatory Audit Report for EPRI Technical Report 3002028673, Loss-of-Coolant-Accident-Induced Fuel Fragmentation, Relocation and Dispersal with Leak-Before-Break Credit - Alternative Licensing Strategy Project stage: Other ML26033A4732026-02-0606 February 2026 E-Mail - Issuance of Regulatory Audit Report for EPRI Technical Report 3002028673, Loss-of-Coolant-Accident-Induced Fuel Fragmentation, Relocation and Dispersal with Leak-Before-Break Credit - Alternative Licensing Strategy Project stage: Approval ML26030A0292026-02-0909 February 2026 E-mail - Issuance of Safety Evaluation for EPRI Technical Report 3002028674/5, LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop, and 4-Loop Plants, for Proprietary Review Project stage: Approval 2025-02-03
[Table View] |
Text
August 27, 2024 Aylin Kucuk Program Manager, Nuclear Fuels Electric Power Research Institute 3420 Hillview Avenue Palo Alto, CA 94304-1338
SUBJECT:
REVISION OF DATES FOR REVIEW OF ELECTRIC POWER RESEARCH ALTERNATIVE LICENSING STRATEGY TOPICAL REPORTS (EPID NOS. L-2024-NTR-0002, L-2024-NTR-0003, L-2024-NTR-0004)
Dear Aylin Kucuk:
By letter dated June 25, 2024 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML24170A813), the U.S. Nuclear Regulatory Commission (NRC) communicated that the following reports submitted by Electric Power Research Institute (EPRI) contain sufficient material to begin review.
(1) EPRI Report 3002028673, Loss-of-Coolant-Accident (LOCA)-Induced Fuel Fragmentation, Relocation and Dispersal (FFRD) with Leak-Before-Break (LBB)
Credit - Alternative Licensing Strategy (ALS)
(2) EPRI Report 3002028675 (NP)/3002028674 (P), LOCA Analysis of Fuel Fragmentation, Relocation, and Dispersal for Westinghouse 2-Loop, 3-Loop and 4-Loop Plants - Proprietary, Evaluation of Cladding Rupture in High Burnup Fuel Rods Susceptible to Fine Fragmentation (3) EPRI Report 3002023895, Materials Reliability Program: xLPR Estimation of PWR
[Pressurized Water Reactor] Loss-of-Coolant Accident Frequencies (MRP-480)
The purpose of this letter is to inform EPRI that the NRC has approved a revision to the original schedule to better manage resources and improve efficiency which can be found on the following table. Note that although intermediate milestones have shifted, neither the completion date of the package nor the anticipated review hours have changed.
EPRI Report MRP-480 Report 3002028674/5 Report 3002028673 Audit Dates March/April 2025 January/February 2025 May/June 2025 Request for Additional Information Issuance May 23, 2025 July 18, 2025 July 21, 2025 Draft SE Issuance December 4, 2025 February 6, 2025 February 17, 2026 Review Hours 1500 1500 1500
EPRI Report MRP-480 Report 3002028674/5 Report 3002028673 ADAMS Accession No. for TR Completeness Determination Form ML24170A902 ML24170A891 ML24170A857 Previous Enterprise Project Identifier (EPID)
Code L-2024-TOP-0016 L-2024-TOP-0015 L-2024-TOP-0018 New EPID Code L-2024-NTR-0004 L-2024-NTR-0003 L-2024-NTR-0002 By letter dated April 26, 2024, EPRI submitted a fee exemption request to the NRC Chief Financial Officer (ADAMS Accession No. ML24121A209). By letter dated August 1, 2024, NRC granted the fee exemption request (ADAMS Accession No. ML24170A671). The table above reflects a change to new EPID codes based on the granting of the fee exemption.
If you have questions regarding this matter, please contact Lois James via e-mail at Lois.James@nrc.gov or James Delosreyes via e-mail at James.Delosreyes@nrc.gov.
Sincerely,
/RA/
Gerond A. George, Branch Chief Licensing Project Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No: 99902021
ML24225A135 OFFICE NRR/DORL/LLPB/PM NRR/DORL/LLPB/LA NRR/DNRL/NVIB/BC NAME DMurray DHarrison ABuford DATE 8/12/2024 08/15/2024 08/26/2024 OFFICE NRR/DSS/LLPB/BC NRR/DORL/LLPB/BC NAME SKrepel GGeorge DATE 08/27/2024 08/27/2024